Plan Review Details - Permit 16080298
| Plan Review Stops For Permit 16080298 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2016-09-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-09-15 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-09-13 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2016-09-14 11:23:38 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-08-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-08-30 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-08-26 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2016-08-29 11:04:26 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-08-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-08-16 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-08-12 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2016-08-12 16:17:42 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-08-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-08-09 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-08-08 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2016-08-08 14:49:47 | MECHANICAL INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2016-09-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-09-15 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-09-15 |
Time |
10:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2016-08-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-08-30 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-08-30 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2016-08-30 10:14:03 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT 316080298 | | | 8/30/16 | | | | | | 1) THE RESUBMITTED PLANS MUST BEAR THE ORIGINAL | | | SIGNATURE AND SEAL OF THE ARCHITECT ANTHONY A. | | | HARRINGTON AIA- REFER TO SECTION 61G1-16.003 FLORIDA | | | ADMINISTRATIVE CODE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-08-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-08-16 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-08-16 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2016-08-16 07:52:34 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #16080298 | | | 8/16/16 | | | | | | 1) REFER TO SECTION 501.2 FBC-14 MECHANICAL. THE DRYER | | | EXHAUST AND THE KITCHEN HOOD EXHAUST CAN NOT BE IN THE | | | SAME CHASE AS THE BATHROOM EXHAUST- PLEASE CORRECT. | | | | | | 2) INDICATE THE DIMENSIONS OF THE MAIN SUPPLY PLENUM | | | AND VERIFY IT IS SIZED LARGE ENOUGH FOR 1600 CFMS. | | | PLEASE NOTE THAT A 35X5" DUCT IS UNDERSIZED PER ASHRAE | | | APPROVED DUCTULATORS. | | | | | | 3) NOTE #2 IS INDICATING THE NEW CEILING HEIGHT WILL BE | | | 7 FT. PLEASE SEE SECTION 1208.2 FBC-14 BUILDING AND | | | VERIFY THAT THE 7 FT. CEILING HEIGHT IS LIMITED TO THE | | | KITCHEN, THE BATHROOMS, THE LAUNDRY ROOM, AND STORAGE | | | ROOMS. | | | | | | 4) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE DRYER. | | | PLEAS NOTE MAKEUP AIR MAY BE REQUIRED PER SECTION | | | 504.5. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-08-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-08-09 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-08-09 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2016-08-09 09:16:55 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #16080298 | | | 8/9/16 | | | | | | 1) PLEASE ENLARGE THE PRINT SO THAT ALL RIGID AND FLEX | | | DUCT SIZES, DIFFUSER SIZES, AND SUPPLY CFMS CAN BE SEEN | | | CLEARLY FOR REVIEW. | | | | | | 2) THE RETURN AIR SYSTEM APPEARS TO BE AN ABOVE-CEILING | | | RETURN AIR PLENUM. PLEASE PLACE A NOTE ON THE PLAN TO | | | CLEARLY IDENTIFY IT AS SUCH, AND REFER TO SECTION | | | 606.2.2.1 FOR MATERIALS WITHIN PLENUMS. | | | | | | 3) INDICATE HOW AIR IS BEING RETURNED FROM THE LIVING | | | ROOM AND BREAKFAST ROOM. DOES THE HALL CLOSET HAVE A | | | LOUVERED DOOR AND A RETURN GRILL IN THE CEILING? PLEASE | | | SEE SECTION C403.2.7.2 FOR MECHANICAL CLOSET | | | COMPLIANCE. | | | | | | 4) CLARIFY THE PURPOSE OF THE HOOD EXHAUST IN THE | | | LAUNDRY ROOM, INDICATE THE MAKE AND MODEL OF THE | | | APPLIANCE IT IS SERVING. PLEASE NOTE THAT IF WHAT IS | | | DEPICTED IS DRYER EXHAUST, THEN THE EXHAUST DUCT SHALL | | | BE MINIMUM 4" IN DIAMETER PER SECTION 504.6.1. | | | | | | 5) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | | WASHER/DRYER. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
|