| Plan Review Stops For Permit 16071233 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-09-16 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-09-16 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-09-16 |
Time |
14:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-09-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-09-02 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-09-01 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2016-09-02 08:44:06 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER ? PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1. STRUCTURE IDENTIFCATION ON PLAN PAGE C-1 SHOULD READ | | | "PROPOSED 2 STORY RESIDENCE". | | | 2. PROVIDE DESIGN WIND LOADS FOR DOOR AND WINDOW | | | OPENINGS. | | | 3. PROVIDE PRODUCT APPROVALS FOR ALL WINDOWS. | | | | | | FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-R301.2. | | | 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | 2. RISK CATEGORY. | | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. | | | 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | | M2). | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY | | | FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. SPECIFICALLY, PROVIDE WINDOW | | | SUBMITTALS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-08-01 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-08-01 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-08-01 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2016-08-01 17:36:58 | ELECTRICAL REVIEW NOTES | | | REVIEWED FOR COMPLIANCE WITH: | | | 5TH EDITION FBC 2014 & NFPA 70 2011 (NEC) | | | | | | EVEN THOUGH THE ELECTRICAL PLAN REVIEW WAS APPROVED, | | | THERE ARE TWO NOTES BEING ADDED TO THE APPROVED | | | DRAWINGS: | | | 1. THE GENERATOR IS ADDRESSED ON THIS SET OF PLANS BUT | | | IF AND WHEN IT IS TO BE INSTALLED, IT SHALL BE UNDER A | | | SEPARATE PERMIT AND SUBMITTAL. THE GENERATOR PERMIT | | | MUST BE ACCOMPANIED BY GENERATOR SPECS AND A REVISED | | | ELECTRICAL RISER DIAGRAM. | | | 2. CORRECTION TO THE FBC-R ENERGY CONSERVATION NOTE TO | | | BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE | | | FBC-RE404.1 TO WHICH 75% OF ALL PERMANENTLY INSTALLED | | | LAMPS SHALL OF THE HIGH EFFICIENCY TYPE. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-09-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-09-21 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-09-09 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2016-09-09 14:09:42 | RESUB ROUTED TO NJWIRA VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-09-06 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2016-09-06 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2016-07-29 |
Time |
15:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
P |
Date |
2016-09-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-09-01 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-09-01 |
Time |
15:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
N |
Date |
2016-08-02 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
2016-08-02 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
2016-08-02 |
Time |
16:55 |
Sent To |
M |
|
| Notes |
| 2016-08-02 16:57:57 | SEPARATE LANDSCAPE PERMIT REQUIRED, MUST SUBMIT PRIOR | | | TO ISSUANCE OF THIS PERMIT. LANDSCAPE PLANS ARE IN THIS | | | PERMIT, NEED TO BE REMOVED AND SUBMITTED WITH LANDSCAPE | | | PERMIT APPLICATION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2016-09-06 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2016-09-06 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2016-09-06 |
Time |
10:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-09-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-09-20 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-09-20 |
Time |
12:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-08-24 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-08-24 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-08-24 |
Time |
06:22 |
Sent To |
|
|
| Notes |
| 2016-08-24 07:00:16 | 1) SHTS. C1 & EC 1 DESIGNATE THE BUILDING AS A PROPOSED | | | ONE STORY STRUCTURE YET THE ARCHITECTURAL/PLUMBING ETC. | | | PLANS SHOW A TWO STORY BUILDING. CLARIFY. | | | 2) THE WATER CLOSET AND SHOWER IN THE MASTER BATH ISS | | | NOT VENTED. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2016-09-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-09-01 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-09-01 |
Time |
15:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2016-09-15 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2016-09-15 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-09-12 |
Time |
14:26 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-08-02 |
|
|
Cont ID |
|
| Sent By |
nwair |
Date |
2016-08-02 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-08-02 |
Time |
16:17 |
Sent To |
L |
|
| Notes |
| 2016-08-02 16:26:52 | 8/2/16- PASSED | | | | | | SF-7 SINGLE FAMILY LOW DENSITY RESIDENTIAL | | | | | | 1. 100FT. WIDE MEETS THE 60FT. LOT WIDTH REQUIREMENT. | | | 2. LOT SIZE IS 19,022SQFT. MEETS THE 6,000 SQFT. LOT | | | REQUIREMENT. | | | 3. FRONT SETBACK IS 49.8 MEETING THE 25FT. FRONT | | | SETBACK REQUIREMENT. | | | 4. REAR SETBACK IS 83.5FT. MEETING THE 15FT. REAR | | | SETBACK REQUIREMENT. | | | 5. SIDE SETBACK IS 5.1FT. MINIMUM AND 16.7FT. TOTAL | | | MEETING THE 5FT. MINIMUM AND 15FT. TOTAL SIDE SETBACK | | | REQUIREMENT. | | | 6. A/C UNIT IS NOT LOCATED WITHIN A REQUIRED SETBACK. | | | 7. POOL IS EXISTING AND ON A SEPORATE PERMIT. | | | 8. ONE KITCHEN SO ONE UNIT ON THE PROPERTY. | | | 9. BUILDING HEIGHT IS 25FT. 10IN. MEETING THE 30FT. | | | HEIGHT LIMIT IN THE DISTRICT. | | | 10. ROOF OVERHANG IS 1FT. 6IN. MEETING THE 3FT. LIMIT | | | INTO A REQUIRED SETBACK. | | | 11. 11,670 OF IMPERVIOUS SURFACE MEETS THE 1,000FT. OF | | | REQUIRED IMPERVIOUS SURFACE. | | | 12. ACCESSORY STRUCTURES MEET THE SIZE AND SETBACK | | | REQUIREMENTS. | | | 13. NO TREES BEING REMOVED | | | 14. GAZEBO IS NOT LOCATED WITHIN A REQUIRED SETBACK | | | ALONG WITH THE DECK. | | | 15. DRIVEWAY IS 18FT. MEETING THE 20FT. LIMIT AND NOT | | | WITHIN THE 20FT. SIDE SETBACK. | | | | | | PLEASE CONTACT: | | | NATHAN WIRA | | | (561)822-1442 | | | [email protected] | | | |
|
|