| 2016-10-14 07:11:26 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 16070909 |
| | ADD: 5112 GEORGIA AVE. |
| | CONT: TD GONE BUILDING |
| | TEL: 561-436-4047 |
| | E-MAIL; [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: FRI. 14/ 2016 |
| | ACTION: DENIED |
| | |
| | 1) 2ND REQUEST . ORIGINALLY 3 SETS OF PLANS SUBMITTED. |
| | ON THE RE-SUBMITTAL ONLY 2 SETS OF PLANS WERE |
| | SUBMITTED. ONLY 2 SOILS REPORTS WERE SUBMITTED. THIS IS |
| | A RESIDENT INSPECTOR PROJECT REQUIRING 3 SETS OF |
| | DOCUMENTS. 2014 FLORIDA BUILDING CODE W 2014 WEST PALM |
| | BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER |
| | 1, ADMINISTRATION 110.3.9. |
| | 1ST ROUND COMMENTS. FOR RESIDENT INSPECTOR PROJECTS 3 |
| | SETS OF PLANS ARE REQUIRED. ONE FOR CITY RECORD |
| | RETENTION, ONE FOR THE CONTACTOR AND THE 3RD SET FOR |
| | THE RESIDENT INSPECTOR. 2014 FLORIDA BUILDING CODE W |
| | 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION 107.1. |
| | |
| | 2) SEMI-COMPLIED ONLY 2 SETS OF PLANS. |
| | 1ST ROUND OF COMMENTS. THE SHEET A100 DESIGNED BY |
| | ANGELIO DAVILA # 16639 HAS NOT SIGNED NOR SEALED THE |
| | ARCHITECTURAL PLANS. PLANS, SPECIFICATIONS, REPORTS OR |
| | OTHER DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND |
| | BEING FILED FOR PUBLIC RECORD SHALL HAVE THE SIGNATURE |
| | AND SEAL OF THE DESIGN PROFESSIONAL AFFIXED TO THE |
| | DOCUMENT. FL ADMIN CODE 61G16.003 ARCHITECTS. |
| | |
| | 3)COMPLIED |
| | |
| | 4) COMPLIED |
| | |
| | 5) 2ND REQUEST. CONTRACTOR AT OWN RISK!!! |
| | SHEET S1 DETAIL 3 & 4 BOTH SHOW THE USE OF A ROOF TOP |
| | PRESSURE TREATED 4 X 4. PLEASE NOTE PITCH PANS HAVE NOT |
| | BEEN USED IN THE CODE FOR SOME TIME NOW. PLEASE REVIEW |
| | UNDER THE 2014 FBC-B 1509.6.5 AND TABLE 1509.6.5. |
| | 1509.6.5 MECHANICAL UNITS. ROOF MOUNTED MECHANICAL |
| | UNITS SHALL BE MOUNTED ABOVE THE ROOF SURFACE, OR WHERE |
| | ROOFING MATERIALS EXTEND BENEATH THE UNIT, ON RAISED |
| | EQUIPMENT SUPPORTS PROVIDING A MINIMUM CLEARANCE HEIGHT |
| | IN ACCORDANCE WITH TABLE 1509.6.5. |
| | |
| | 6) COMPLIED |
| | |
| | 7) 2ND REQUEST. THE RESPONSE INDICATES THE BUILDING |
| | PERMIT HAS TO BE ISSUED BEFORE THE FIRE SPRINKLER CAN |
| | APPLY FOR THEIR PERMIT. 2014 FBC-B 903.2.4.1 |
| | WOODWORKING OPERATIONS. AN AUTOMATIC SPRINKLER SYSTEM |
| | SHALL BE PROVIDED THROUGHOUT ALL GROUP F-1 OCCUPANCY |
| | FIRE AREAS THAT CONTAIN WOODWORKING OPERATIONS IN |
| | EXCESS OF 2,500 SQUARE FEET (232 M2) IN AREA WHICH |
| | GENERATE FINELY DIVIDED COMBUSTIBLE WASTE OR USE FINELY |
| | DIVIDED COMBUSTIBLE MATERIALS. |
| | THIS IS A BUILDING CODE ISSUE THAT HAS TO BE SATISFIED |
| | BEFORE PERMIT ISSUANCE, THE FIRE SPRINKLER DESIGN |
| | DOCUMENTS ARE REQUIRED TO BE SUBMITTED REVIEWED AND |
| | APPROVED BEFORE ISSUANCE OF A PERMIT. A SECOND SET OF |
| | FIRE SPRINKLER PLANS WILL BE REQUIRED, AND TO SUBMIT |
| | SEPARATELY UNDER A SEPARATE PERMIT, REVIEW AND |
| | ASSOCIATED FEES. |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR |
| | BUILDINGS. |
| | 107.3.5.1 COMMERCIAL BUILDINGS: |
| | 107.3.5.1.1 BUILDING |
| | (5) FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: |
| | SCHEMATIC FIRE SPRINKLERS |
| | PRE-ENGINEERED SYSTEMS |
| | |
| | NOTICE!!!!! FLORIDA STATUTE 553.80(2)(B) WITH RESPECT |
| | TO EVALUATION OF DESIGN PROFESSIONALS? DOCUMENTS, IF A |
| | LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO |
| | ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND |
| | ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY |
| | THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A |
| | CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN |
| | EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, |
| | FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, |
| | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, |
| | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER |
| | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING |
| | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL |
| | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH |
| | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, |
| | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE |
| | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. |
| | |
| | |
| | 1ST ROUND OF COMMENTS. THE ARCHITECTURAL PLANS ARE |
| | SILENT ABOUT THE REQUIREMENTS FOR FIRE SPRINKLERS IN |
| | THE RELOCATED DUST COLLECTOR DUCT. 2014 FBC-B 903.2.4.1 |
| | WOODWORKING OPERATIONS. AN AUTOMATIC SPRINKLER SYSTEM |
| | SHALL BE PROVIDED THROUGHOUT ALL GROUP F-1 OCCUPANCY |
| | FIRE AREAS THAT CONTAIN WOODWORKING OPERATIONS IN |
| | EXCESS OF 2,500 SQUARE FEET (232 M2) IN AREA WHICH |
| | GENERATE FINELY DIVIDED COMBUSTIBLE WASTE OR USE FINELY |
| | DIVIDED COMBUSTIBLE MATERIALS. |
| | |
| | 8-10) COMPLIED. |
| | |
| | 11) WHEN RESUBMITTING PLANS PLEASE INDICATE THE |
| | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES |
| | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |