| 2016-07-21 14:48:34 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 16070373 |
| | ADD: 4275 45TH ST. |
| | CONT: NUNNO BUILDERS |
| | TEL: 954-961-0777 |
| | E-MAIL: |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: THURS. JULY 21/ 2016 |
| | ACTION: DENIED |
| | |
| | 1) PLEASE NOTE SHEET T1.0 UPPER CENTER PORTION OF PLANS |
| | THE JOBSITE LOCATION GIVEN: MIAMI REGION. 14670 SW 8TH |
| | ST. MIAMI, MIAMI-DADE COUNTY, FL. |
| | AND ON THE RIGHT SIDE OF THE PAGE IN THE TITLE BLOCK |
| | THE ADDRESS OF 4275 45TH ST. WEST PALM BEACH, FL. |
| | PLEASE CORRECT THE DISCREPANCY IN ADDRESSES. |
| | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY |
| | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE |
| | WORK. DISCREPANCY IN PLANS. |
| | |
| | 2) SHEET T1.0 THE BUILDING DATA UNDER THE OCCUPANCY |
| | GROUP LIST THIS AS A: C5.1 PLEASE NOTE THIS IS NOT A |
| | OCCUPANCY CLASS FOUND IN THE 2014 FBC-B CHAPTER 3. |
| | |
| | 3) SHEET T1.0 UNDER THE HEADING OF BUILDING DATA LIST |
| | THIS BUILDING AS CLASSIFICATION TYPE AS IIB. PLEASE |
| | NOTE ALL PERMIT PULLED IN THE PAST LIST THE BUILDING AS |
| | A TYPE VB? ADDITIONAL INFORMATION IS REQUIRED. |
| | 107.2.1.3. |
| | |
| | 4) PLEASE NOTE ALL OF THE ARCHITECTURAL SHEETS SIGNED |
| | BY NICK JONIHAKIS ARE COPIES OF SIGNATURES YOU CAN SEE |
| | THE PIXALATION IN THE SIGNATURE. |
| | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS |
| | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR |
| | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE |
| | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. FL ADMIN |
| | CODE 61G16.003 ARCHITECTS. PLANS ARE TO BE SIGNED WITH |
| | A FULL SIGNATURE FROM THE ARCHITECT OF RECORD PER |
| | 481.221 WITH A MINIMUM OF FIRST AND LAST NAME AS SHOWN |
| | ON THE ARCHITECTS' LICENSE, FAC 61G1-16.003. |
| | |
| | 5) THE COMCHECK SUBMITTED HAS A COPY OF AN ELECTRONIC/ |
| | DIGITAL SIGNATURE. 61G15-23.005 PROCEDURES FOR SIGNING |
| | AND SEALING ELECTRONICALLY TRANSMITTED PLANS, |
| | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. |
| | |
| | 6) SHEET A1.0 NOTES 1 & 4 INDICATE NEW MODULAR |
| | COUNTERS, SHEET A1.1 SHOWS CUT SECTION THROUGH THESE |
| | UNITS. THE PLANS DO NOT SHOW COMPLIANCE WITH THE 2014 |
| | FBC-ACCESS. CODE: |
| | |
| | 904.4 SALES AND SERVICE COUNTERS. SALES COUNTERS AND |
| | SERVICE COUNTERS SHALL COMPLY WITH 904.4.1 OR 904.4.2. |
| | THE ACCESSIBLE PORTION OF THE COUNTER TOP SHALL EXTEND |
| | THE SAME DEPTH AS THE SALES OR SERVICE COUNTER TOP. |
| | EXCEPTION: IN ALTERATIONS, WHEN THE PROVISION OF A |
| | COUNTER COMPLYING WITH 904.4 WOULD RESULT IN A |
| | REDUCTION OF THE NUMBER OF EXISTING COUNTERS AT WORK |
| | STATIONS OR A REDUCTION OF THE NUMBER OF EXISTING MAIL |
| | BOXES, THE COUNTER SHALL BE PERMITTED TO HAVE A PORTION |
| | WHICH IS 24 INCHES (610 MM) LONG MINIMUM COMPLYING WITH |
| | 904.4.1 PROVIDED THAT THE REQUIRED CLEAR FLOOR OR |
| | GROUND SPACE IS CENTERED ON THE ACCESSIBLE LENGTH OF |
| | THE COUNTER. |
| | |
| | 904.4.1 PARALLEL APPROACH. A PORTION OF THE COUNTER |
| | SURFACE THAT IS 36 INCHES (915 MM) LONG MINIMUM AND 36 |
| | INCHES (915 MM) HIGH MAXIMUM ABOVE THE FINISH FLOOR |
| | SHALL BE PROVIDED. A CLEAR FLOOR OR GROUND SPACE |
| | COMPLYING WITH 305 SHALL BE POSITIONED FOR A PARALLEL |
| | APPROACH ADJACENT TO THE 36 INCH (915 MM) MINIMUM |
| | LENGTH OF COUNTER. EXCEPTION: WHERE THE PROVIDED |
| | COUNTER SURFACE IS LESS THAN 36 INCHES (915 MM) LONG, |
| | THE ENTIRE COUNTER SURFACE SHALL BE 36 INCHES (915 MM) |
| | HIGH MAXIMUM ABOVE THE FINISH FLOOR. |
| | |
| | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |
| | |
| | |