Plan Review Details - Permit 16070337
Plan Review Stops For Permit 16070337
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-09-22 Cont ID  
Sent By jwitmer Date 2016-09-22 Time 07:58 Rev Time 0.00
Received By jwitmer Date 2016-09-22 Time 07:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-08-04 Cont ID  
Sent By jwitmer Date 2016-08-04 Time 08:14 Rev Time 0.00
Received By jwitmer Date 2016-08-04 Time 07:31 Sent To  
Notes
2016-08-04 08:14:48BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16070337
 ADD: 8170 OKEECHOBEE BLVD SUITE 8 & 9
 CONT: ATLANTIC ENGINEERING ESERVICES INC.
 TEL: 561-358-4140
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. AUGUST 04/2016
 ACTION: DENIED
  
 1) THE COVERSHEET INDICATES THE BUILDING IS
 NON-SPRINKLERED. UNDER THE HEADING EGRESS REQUIREMENTS
 SECTION D THE PLANS QUOTE THE CODE SECTION FOR 1/3 THE
 DISTANCE APART FOR EGRESSES FBC2014 1015.2.1 PLEASE
 NOTE THIS SECTION IS FOR FIRE SPRINKLERED BUILDINGS.
 PLEASE CORRECT THIS BUILDING IS NON-SPRINKLERED.
  
 2) SHEET A1.00 DETAIL 4 SHOWS THE WATER CLOSET GRAB
 BARS MEASURED CENTERLINE FROM THE FLOOR TO THE
 CENTERLINE OF THE GRAB BAR. PLEASE SEE UNDER THE 2014
 FBC-ACCESS. CODE SECTION 609.4 POSITION OF GRAB BARS.
 GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION,
 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM)
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF
 THE GRIPPING SURFACE.
  
 3) A1.00 THE MIRROR LOCATION SHALL BE LOCATED A MAXIMUM
 OF 40 INCHES FROM THE FINISH FLOOR TO THE BOTTOM OF THE
 REFLECTING SURFACE, SEE THE 2014 FBC-ACCESS. CODE
 SECTION 603.3.
  
 4) SHEET A1.00 SIGNAGE INDICATES SIGNAGE AT A HEIGHT OF
 60 INCHES, FIGURE 703.3.2 POSITION OF BRAILLE. 703.4
 INSTALLATION HEIGHT AND LOCATION. SIGNS WITH TACTILE
 CHARACTERS SHALL COMPLY WITH 703.4.
  
 ACCESS. CODE 703.4.1 HEIGHT ABOVE FINISH FLOOR OR
 GROUND. TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48
 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND
 SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST
 TACTILE CHARACTER AND 60 INCHES MAXIMUM ABOVE THE
 FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE
 BASELINE OF THE HIGHEST TACTILE CHARACTER.
  
 5) SHEET A2.00 SHOWS A BREAK ROOM WITH DETAILS FOUND ON
 A8.02 DETAIL # 6. PLEASE SEE THE SHEET A2.00 THE PLANS
 INDICATE THE USE OF A MICROWAVE OVEN, THE MICROWAVE
 OVEN IS NOT SHOWN IN THE DETAILS FOUND ON A8.02. PLEASE
 PROVIDE COMPLIANCE WITH:
 2014 ACCESS CODE REACH RANGES 308.1. & 309.2, 309.3 &
 309.4.
  
 6) SHEET M2 INDICATES A NEW ROOFTOP RTU, ATTACHING TO
 AN EXISTING CURB. PLEASE PROVIDE THE MANUFACTURERS
 SPECIFICATIONS FOR THE CURB ADAPTOR, ANCHORING OF THE
 CURB ADAPTOR TO THE CURB AND THE RTU TO THE CURB
 ADAPTOR. 2014 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON
 STRUCTURAL MEMBERS AND THEIR CONNECTIONS SHALL BE
 DETERMINED BY METHODS OF STRUCTURAL ANALYSIS THAT TAKE
 INTO ACCOUNT EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC
 COMPATIBILITY AND BOTH SHORT- AND LONG-TERM MATERIAL
 PROPERTIES. EVERY STRUCTURE SHALL BE DESIGNED TO RESIST
 THE OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES
 SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND
 LOADS.
 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-10-25 Cont ID  
Sent By albarran Date 2016-10-25 Time 11:23 Rev Time 0.00
Received By albarran Date 2016-10-25 Time 10:25 Sent To I
Notes
2016-10-25 11:25:38ELECTRICAL REVIEW APPROVED. ALL PREVIOUSLY MENTIONED
 DEFICIENCIES HAVE BEEN SATISFACTORILY ADDRESSED.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-07-21 Cont ID  
Sent By albarran Date 2016-07-21 Time 09:52 Rev Time 0.00
Received By albarran Date 2016-07-20 Time 16:30 Sent To  
Notes
2016-07-21 09:52:58ELECTRICAL REVIEW NOTES
 REVIEWED FOR COMPLIANCE WITH: 5TH EDITION FBC 2014 &
 NFPA 70 2011 (NEC)
  
 JOB NAME: NORTH AMERICAN TITLE COMPANY
 JOB ADDRESS: 8170 OKEECHOBEE BLVD. SUITE 8 & 9
 DESCRIPTION: TENNANT BUILD OUT
 MAST. PERMIT: 16070337
 REVISION/SUB-PERMIT:
  
 1. NEC 600.5 REQUIRED BRANCH CIRCUIT: EACH COMMERCIAL
 BUILDING AND EACH COMMERCIAL OCCUPANCY ACCESSIBLE TO
 PEDESTRIANS SHALL BE PROVIDED WITH AT LEAST ONE 20 AMP
 DEDICATED OUTLET IN AN ACCESSIBLE LOCATION AT EACH
 ENTRANCE TO EACH TENANT SPACE FOR SIGN OR OUTLINE
 LIGHTING. SERVICE HALLWAYS OR CORRIDORS SHALL NOT BE
 CONSIDERED ACCESSIBLE TO PEDESTRIANS. THE SIDE DOOR
 SHALL THEREFORE BE PROVIDED WITH A SIGN OUTLET AS WELL.
 2. PER FBC-EC405.7 ELECTRICAL POWER (MANDATORY):
 ACCORDING TO ASHRAE STANDARD 90.1, A MINIMUM OF 50% OF
 ALL 15 & 20 AMP, 125 V. RECEPTACLES SHALL BE
 AUTOMATICALLY CONTROLLED. SEE CODE FOR DETAILS.
 3. FBC.EC405.2.2.3 DAYLIGHT ZONE CONTROL: DAYLIGHT
 ZONES SHALL BE DESIGNED SUCH THAT LIGHTS IN THE
 DAYLIGHT ZONE ARE CONTROLLED INDEPENDENTLY OF GENERAL
 AREA LIGHTING AND ARE CONTROLLED IN ACCORDANCE WITH
 EITHER SECTION C405.2.2.3.1 OR SECTION
 C405.2.2.3.2.THEREFORE, LIGHTING CIRCUITS A10 & A8
 SHALL BE DESIGNATED DAYLIGHT ZONES FOR INDEPENDENT
 CONTROL.
 4. FBC-E405.5.2 INTERIOR LIGHTING POWER: THE TOTAL
 INTERIOR POWER ALLOWANCE IS DETERMINED ACCORDING TO THE
 APPLICABLE TABLES AS INDICATED IN THIS SECTION.
 THEREFORE, PROVIDE A LIGHT DENSITY ALLOWANCE CHART
 SHOWING COMPLIANCE WITH MINIMUM LIGHT ALLOWANCE
 REQUIREMENTS AS PRESCRIBED BY CODE.
 5. NEC 110.16 ARC-FLASH HAZARD WARNING: ELECTRICAL
 EQUIPMENT IN OTHER THAN DWELLING UNITS LIKELY TO
 REQUIRE SERVICE WHILE ENERGIZED SHALL BE FIELD MARKED
 TO WARN AGAINST POTENTIAL ARC-FAULT HAZARDS.
 6. NEC 408.4(B) ALL SWITCHBOARDS AND PANELBOARDS
 SUPPLIED BY A FEEDER IN OTHER THAN A ONE OR TWO FAMILY
 DWELLING SHALL BE MARKED TO INDICATE THE LOCATION AND
 TYPE OF THE SOURCE OF POWER.
 7. FBC-E C405.7.3 VOLTAGE DROP: FEEDERS & CUSTOMER
 OWNED SERVICE CONDUCTORS SHALL BE SIZED FOR A MAXIMUM
 OF 2% VOLTAGE DROP. SINCE THE DISTANCE BETWEEN THE MAIN
 AND THE PANELS IS NOT PROVIDED, VOLTAGE DROP
 CALCULATIONS SHALL BE INCLUDED ON PLANS.
  
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER
 WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD
 CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID
 AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE
 GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-09-21 Cont ID  
Sent By wjolin Date 2016-09-21 Time 13:23 Rev Time 0.00
Received By wjolin Date 2016-09-21 Time 13:18 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2016-07-14 Cont ID  
Sent By wjolin Date 2016-07-14 Time 16:40 Rev Time 0.00
Received By wjolin Date 2016-07-14 Time 15:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-10-26 Cont ID  
Sent By ccole Date 2016-10-26 Time 16:05 Rev Time 0.00
Received By ccole Date 2016-10-26 Time 12:02 Sent To  
Notes
2016-10-26 12:03:14CCOLE'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-10-25 Cont ID  
Sent By albarran Date 2016-10-25 Time 11:28 Rev Time 0.00
Received By albarran Date 2016-09-14 Time 10:26 Sent To  
Notes
2016-10-25 11:30:0710/25/16 COMPLETED THE REVIEW PROCESS. NEEDS MECHANICAL
 APPROVAL. CONTRACTOR NOTIFIED VIA EMAIL. FILE SENT TO
 LARGE DENIED DRAWER A. MA
2016-09-16 10:26:31B21

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-08-04 Cont ID  
Sent By jwitmer Date 2016-08-04 Time 08:15 Rev Time 0.00
Received By jwitmer Date 2016-07-12 Time 09:36 Sent To  
Notes
2016-07-13 09:36:14B31

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2016-08-04 Cont ID  
Sent By jwitmer Date 2016-08-04 Time 07:31 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2016-10-26 Cont ID  
Sent By ccole Date 2016-10-26 Time 16:09 Rev Time 0.00
Received By ccole Date 2016-10-26 Time 16:09 Sent To  
Notes
2016-10-26 16:11:29MECHANICAL PROVISO
 10/25/16
  
 REVISON REQUIRED TO INCREASE THE CAPACITIES OF THE HEAT
 STRIPS IN THE THE RTU'S BASED ON THE REVISED AC
 CALCULATIONS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-09-20 Cont ID  
Sent By ccole Date 2016-09-20 Time 15:06 Rev Time 0.00
Received By ccole Date 2016-09-20 Time 15:06 Sent To  
Notes
2016-09-20 15:09:412ND REVIEW FBC-2014 MECHANICAL
 PERMIT #16070337
 9/20/16
  
 1) THE OWNER/AGENT MUST SIGN THE SUBMITTED ENERGY
 COMPLIANCE FORM C402- SECTION C103.1.1.2 FBC-14 ENERGY
 COMPLIANCE
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-07-20 Cont ID  
Sent By ccole Date 2016-07-20 Time 06:53 Rev Time 0.00
Received By ccole Date 2016-07-19 Time 17:12 Sent To  
Notes
2016-07-20 07:11:251ST REVIEW MECHANICAL
 PERMIT #16070337
 7/20/16
  
 1) M1: PROVIDE A DUCT SMOKE DETECTOR IN THE RETURN AIR
 SYSTEM OF RTU-2.
  
 2) M1: & M2: REFER TO TABLE 403.3 AND PROVIDE AN
 EXHAUST VENTILATION CALCULATION FOR THE COPY ROOM, AND
 PROVIDE COMPLETE DETAILS FOR THE EXHAUST SYSTEM- SHOW
 LOCATION OF EXHAUST FAN(S), EXHAUST DUCT RUNS, AND
 PROVIDE FAN EQUIPMENT SCHEDULE(S).
  
 3) M2: AS NOTED IN THE RTU MOUNTING DETAIL, PLEASE
 PROVIDE COMPLETE STRUCTURAL DETAILS FOR ATTACHING THE
 RTU TO THE CURB AND THE CURB TO THE ROOF STRUCTURE-
 SECTION 301.15. SUBMIT MANUFACTURER'S SPECIFICATIONS
 FOR THE CURB ADAPTERS (REFERENCED ON M1) WITH SHOP
 DRAWING APPROVAL SIGNATURE BY THE EOR.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status P Date 2016-10-12 Cont ID  
Sent By shill Date 2016-10-12 Time 08:46 Rev Time 0.00
Received By shill Date 2016-10-12 Time 08:46 Sent To  
Notes
2016-10-12 08:51:14****PROVISO****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 THIS PROPERTY IS LOCATED IN SFHA ZONE AH, DFE MINIMUM
 OF 18.0 FEET
  
 A FORM BOARD SURVEY AND/OR ELEVATION CERTIFICATE IS
 REQUIRED PRIOR TO CONCRETE POUR
  
 A "FINISHED CONSTRUCTION" ELEVATION CERTIFICATE IS
 REQUIRED PRIOR TO C.O.
  
 PER FEMA: WHEN THE MAP JURISDICTION IS INCORRECT DUE TO
 ANNEXATION, SURVEYOR IS TO INCLUDE AN EXPLANATION IN
 THE COMMENTS.
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-09-19 Cont ID  
Sent By tklarge Date 2016-09-19 Time 06:06 Rev Time 0.00
Received By tklarge Date 2016-09-19 Time 05:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-08-01 Cont ID  
Sent By tklarge Date 2016-08-01 Time 06:02 Rev Time 0.00
Received By tklarge Date 2016-08-01 Time 05:35 Sent To  
Notes
2016-08-01 06:00:391) A SERVICE SINK IS REQD. PER TABLE 403.1 OF 2014
 FBC-PLUMBING. THE "SERVICE SINK" IN THE BREAK ROOM DOES
 NOT MEET THIS REQUIREMENT.
 2) SHT. A1.00 - THE MIRROR SHALL BE LOCATED A MAXIMUM
 OF 40 INCHES FROM THE FINISHED FLOOR TO THE BOTTOM OF
 THE REFLECTING SURFACE. FBC-ACCESS. SEC.603.3.
 3) THE TOILET PAPER DISPENSER SHALL BE LOCATED IN
 ACCORDANCE WITH FBC-ACCESS. SEC.604.9.6.
 4) THE BREAKROOM SINK SHALL COMPLY WITH 2014
 FBC-ACCESS. SEC. 606.2 - 606.5.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2016-10-04 Cont ID  
Sent By eschneid Date 2016-10-04 Time 11:45 Rev Time 0.50
Received By eschneid Date 2016-10-04 Time 11:45 Sent To  
Notes
2016-10-04 11:57:50 
  
  