Plan Review Details - Permit 16070183
| Plan Review Stops For Permit 16070183 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2017-05-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-05-11 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-11 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2017-05-11 16:38:29 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16070183 | | | ADD: 518 S. DIXIE HWY. | | | CONT: ECONSTRUCTION LLC | | | TEL: 954-551-1475 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 5TH REVIEW | | | DATE: THURS. MAY 11/ 2017 | | | ACTION: BUILDING PROVISO | | | | | | 1) ) BUILDING PROVISO/ DEFERRED SUBMITTAL. 107.3.4.2. | | | THE DESIGNER OF RECORD HAS REQUESTED THE EXTERIOR | | | COMPONENTS AND CLADDING TO BE A DEFERRED SUBMITTAL. | | | 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS PROVIDED: NOA: 17-0222.14 & NOA 15-0129.05 | | | (C) PANEL WALLS: STOREFRONTS, WALL LOUVERS, EFIS | | | SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | | (G) PRE-ENGINEERED A/C STANDS PROVIDED: NOA: 16-0601.01 | | | | | | FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS WHICH | | | ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR | | | TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2017-05-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-05-10 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-10 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2017-05-10 12:01:17 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16070183 | | | ADD: 518 S. DIXIE HWY. | | | CONT: TBD / TO BE DETERMINED | | | TEL: 954-570-9500 | | | E-MAIL: BRIAN @ TBBG.NET | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 4TH REVIEW | | | DATE: WED. MAY 01/ 2017 | | | ACTION: | | | | | | 1A-E) COMPLETED. | | | | | | 1F) BUILDING PROVISO/ DEFERRED SUBMITTAL. 107.3.4.2. | | | THE DESIGNER OF RECORD HAS REQUESTED THE EXTERIOR | | | COMPONENTS AND CLADDING TO BE A DEFERRED SUBMITTAL. | | | 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | | (G) PRE-ENGINEERED A/C STANDS | | | | | | FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS WHICH | | | ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR | | | TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 2-9) COMPLIED. | | | | | | 10)4TH REVIEW!!!!!!! | | | 4X FEE NOTICE!!!!! FLORIDA STATUTE 553.80(2)(B) WITH | | | RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | WINDOW # 7 IS 4-0 WIDE X 3-4 TALL. IF THIS IS | | | CONSIDERED A DOUBLE CASEMENT WINDOW WITH THE EXTERIOR | | | FRAME ON BOTH SIDES OF THE WINDOW AND THE CENTER | | | VERTICAL MEMBER THE CLEAR WIDTH CANNOT BE 23.6 INCHES | | | AS STATED IN THE RESPONSE! IN THE JELD WEN SERIES | | | WINDOWS A OVERALL CASING (HORIZONTAL MEASUREMENT) 24 | | | 5/16 INCHES HAS A CLEAR FRAME SIZE OF 18 INCHES. | | | EMCOMPASS BY PELLA TO MEET THE MINIMUM REQUIREMENTS OF | | | A CLEAR OPENING OF CLEAR OPENING OF 24 INCHES IN | | | HEIGHT, 20 INCHES IN WIDTH AND THE 5.7 SQ. FT . TYPE E | | | WINDOW 3-0 FT WIDE X 3-5 FT IN HEIGHT. | | | | | | PLEASE PROVIDE THE SIZING CHART FROM ES CASEMENT | | | WINDOWS AND CIRCLE THE WINDOW SIZE AND THE CLEAR | | | OPENING SIZE, THE WIDTH REQUIREMENT, HEIGHT REQUIREMENT | | | AND MINIMUM CLEAR OPENING SIZE OF 5.7 SQUARE FEET. THIS | | | INCLUDES THE BOTH WINDOW TYPE 7 &8. | | | | | | | | | 3RD REVIEW COMMENT. SEMI- COMPLIED. EGRESS WINDOWS | | | CASEMENT SIZE 4-10X 3-4. NOTE WINDOW # 7 IS 4-0X3-4 | | | (DOUBLE CASEMENT WITH MULLION). PROVIDE DOCUMENTATION | | | THAT THE WINDOW WILL HAVE 20 INCHES IN CLEAR WIDTH WITH | | | 5.7 SQUARE FEET OF VENT. | | | | | | 10A) SHEET A-201 & A-202 PLEASE PROVIDE THE CLEAR | | | OPENING SIZE FOR THE WINDOWS (VENT) FOR COMPLIANCE | | | WITH: FBC-B 1029.2 MINIMUM SIZE. EMERGENCY ESCAPE AND | | | RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING | | | OF 5.7 SQUARE FEET. | | | | | | 10B) FBC-B 1029.2.1 MINIMUM DIMENSIONS. THE MINIMUM NET | | | CLEAR OPENING HEIGHT DIMENSION SHALL BE 24 INCHES (610 | | | MM). THE MINIMUM NET CLEAR OPENING WIDTH DIMENSION | | | SHALL BE 20 INCHES (508 MM). THE NET CLEAR OPENING | | | DIMENSIONS SHALL BE THE RESULT OF NORMAL OPERATION OF | | | THE OPENING. | | | | | | 10C) FBC-B 1029.3 MAXIMUM HEIGHT FROM FLOOR. EMERGENCY | | | ESCAPE AND RESCUE OPENINGS SHALL HAVE THE BOTTOM OF THE | | | CLEAR OPENING NOT GREATER THAN 44 INCHES (1118 MM) | | | MEASURED FROM THE FLOOR. | | | | | | 11) COMPLIED. SAFETY GLASS BATHROOM. | | | | | | 12)4TH REVIEW. ROOF PRESSURES ARE VERY LOW, THEY ARE TO | | | BE TAKEN FOR 10 SQ. FT. FOR ROOF FASTENERS. EVEN FOR A | | | B EXPOSURE TAKEN AT 21.5 FT. ELEVATION AT 10 SQ. FT. | | | THE ROOF PRESSURES ARE LOW. | | | ROOF ZONE # 1 INDICATES -19.9 PSF SHOULD BE -31.32 VASD | | | ROOF ZONE # 2 & 3 AT -35.7 PSF SHOULD BE -67.40 VASD | | | | | | 13) 2ND REQUEST, RESTROOM IS REQUIRED ON THE 1ST FLOOR | | | TENANT SPACE. . SHEET A-101 IS MISSING THE RESTROOM IN | | | THE GROCERY STORE/ CONVENIENCE STORE. PLEASE REVIEW | | | SECTION 1210.1 OF THE 2014 FBC-B AND 2902.1.. | | | | | | 14) COMPLIED. IMPACT FEES. | | | | | | 15) 4TH REQUEST. WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE VOIDED SHEETS & REPLACE | | | ANY PAGES AS NECESSARY. A TRANSMITTAL LETTER LISTING | | | THE ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION | | | OF THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2017-02-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-02-01 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-02-01 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2017-02-01 17:26:22 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16070183 | | | ADD: 518 S. DIXIE HWY. | | | CONT: ECONSTRUCTION LLC | | | TEL: 954-570-9500 | | | E-MAIL: BRIAN @ TBBG.NET | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: WED. FEB. 01/ 2017 | | | ACTION: DENIED | | | | | | 1A-E) COMPLETED. | | | | | | 1F) BUILDING PROVISO/ DEFERRED SUBMITTAL. 107.3.4.2. | | | THE DESIGNER OF RECORD HAS REQUESTED THE EXTERIOR | | | COMPONENTS AND CLADDING TO BE A DEFERRED SUBMITTAL. | | | 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | | (G) PRE-ENGINEERED A/C STANDS | | | | | | FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS WHICH | | | ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR | | | TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 2-9) COMPLIED. | | | | | | 10) SEMI- COMPLIED. EGRESS WINDOWS CASEMENT SIZE 4-10X | | | 3-4. NOTE WINDOW # 7 IS 4-0X4-3 (DOUBLE CASEMENT WITH | | | MULLION). PROVIDE DOCUMENTATION THAT THE WINDOW WILL | | | HAVE 20 INCHES IN CLEAR WIDTH WITH 5.7 SQUARE FEET OF | | | VENT. | | | | | | 10A) SHEET A-201 & A-202 PLEASE PROVIDE THE CLEAR | | | OPENING SIZE FOR THE WINDOWS (VENT) FOR COMPLIANCE | | | WITH: FBC-B 1029.2 MINIMUM SIZE. EMERGENCY ESCAPE AND | | | RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING | | | OF 5.7 SQUARE FEET. | | | | | | 10B) FBC-B 1029.2.1 MINIMUM DIMENSIONS. THE MINIMUM NET | | | CLEAR OPENING HEIGHT DIMENSION SHALL BE 24 INCHES (610 | | | MM). THE MINIMUM NET CLEAR OPENING WIDTH DIMENSION | | | SHALL BE 20 INCHES (508 MM). THE NET CLEAR OPENING | | | DIMENSIONS SHALL BE THE RESULT OF NORMAL OPERATION OF | | | THE OPENING. | | | | | | 10C) FBC-B 1029.3 MAXIMUM HEIGHT FROM FLOOR. EMERGENCY | | | ESCAPE AND RESCUE OPENINGS SHALL HAVE THE BOTTOM OF THE | | | CLEAR OPENING NOT GREATER THAN 44 INCHES (1118 MM) | | | MEASURED FROM THE FLOOR. | | | | | | 11) COMPLIED. SAFETY GLASS BATHROOM. | | | | | | | | | 12) ROOF PRESSURES ARE VERY LOW, THEY ARE TO BE TAKEN | | | FOR 10 SQ. FT. FOR ROOF FASTENERS. | | | | | | 13) NEW COMMENT. SHEET A-101 IS MISSING THE RESTROOM IN | | | THE GROCERY STORE/ CONVENIENCE STORE. PLEASE REVIEW | | | SECTION 1210.1 OF THE 2014 FBC-B AND 2902.1.. | | | | | | 14) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 15) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-12-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-12-03 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-12-03 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2016-12-03 11:02:28 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16070183 | | | ADD: 518 S. DIXIE HWY. | | | CONT: TBD / TO BE DETERMINED | | | TEL: 954-570-9500 | | | E-MAIL: BRIAN @ TBBG.NET | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: SAT. DEC. 03/ 2016 | | | ACTION: DENIED | | | | | | 1A)2ND REQUEST. THE BUILDING TYPE HAS NOT CHANGED, THE | | | RESPONSE INDICATES CHANGED FROM A BUILDING TYPE VA TO | | | VB. PLEASE PROVIDE WHAT YOU ARE DEFINING AS A | | | PROTECTED. THE DESIGNER OF RECORD CLASSIFIES THE TWO | | | BUILDINGS AS A SINGLE BUILDING ON THE SAME LOT, NOT | | | REQUIRING THE OPENINGS TO BE PROTECTED BETWEEN | | | BUILDINGS, OR ARE YOU REFERRING TO THE REQUIRED | | | PROTECTION PER TABLE 602, THE CLOSENESS TO THE PROPERTY | | | LINE OR THE 1ST FLOOR REAR EXITING AND THE CLOSENESS OF | | | THE 2ND BUILDING ON THE SAME LOT REQUIRING A CREATING | | | AN EXIT COURT IN COMPLIANCE WITH 2014 FBC-B 1027.4.2 | | | EGRESS COURT CONSTRUCTION AND OPENINGS. | | | 1ST ROUND COMMENT. | | | SHEET A-001 THE COVERSHEET INDICATES UNDER THE HEADING | | | OF KEY PROJECT DATA THIS BUILDING IS A CONSTRUCTION | | | TYPE (VB) PROTECTED. 107.2.1.3 ADDITIONAL INFORMATION | | | IS REQUIRED. NORMALLY THE TERM PROTECTED IS USED AS A | | | FIRE RATING OF STRUCTURAL MEMBERS, AS IN BUILDING TYPE | | | 1A, 1B, IIA, IIIA, IVA OR VA. | | | SEE TABLE 601 FOR FIRE RATINGS OF STRUCTURAL ELEMENTS. | | | | | | 1B) COMPLIED / 2 BUILDINGS ON THE SAME LOT. FBC-B | | | 503.1.2. | | | | | | 1C) 2ND REQUEST, THIS COMMENT DEALS WITH HORIZONTAL | | | FIRE BARRIER REQUIREMENTS!!!! PROVIDE AN FLOOR/CEILING | | | ASSEMBLY !!! THANK YOU. DON?T JUST PUT A FIRE RATING ON | | | THE PLANS SHOWING COMPLIANCE. | | | 1ST ROUND OF COMMENTS. | | | SHEET A-001 UNDER THE HEADING KEY PROJECT DATA DOES NOT | | | LIST THE REQUIREMENTS FOR SEPARATING OCCUPANCIES WITH | | | HORIZONTAL FIRE BARRIER REQUIREMENTS. SHEET A-101 | | | INDICATES 1 HOUR SEPARATION. SEE FBC-B SECTION 707.3.10 | | | FIRE AREAS. THE FIRE BARRIERS OR HORIZONTAL ASSEMBLIES, | | | OR BOTH. THE FIRE BARRIERS OR HORIZONTAL ASSEMBLIES, OR | | | BOTH, SEPARATING FIRE AREAS OF MIXED OCCUPANCIES SHALL | | | HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN THE | | | HIGHEST VALUE INDICATED IN TABLE 707.3.10 FOR THE | | | OCCUPANCIES UNDER CONSIDERATION, 2 HOUR FIRE RATING. | | | | | | 420.3 HORIZONTAL SEPARATION. FLOOR ASSEMBLIES | | | SEPARATING DWELLING UNITS IN THE SAME BUILDINGS, FLOOR | | | ASSEMBLIES SEPARATING SLEEPING UNITS IN THE SAME | | | BUILDING AND FLOOR ASSEMBLIES SEPARATING DWELLING OR | | | SLEEPING UNITS FROM OTHER OCCUPANCIES CONTIGUOUS TO | | | THEM IN THE SAME BUILDING SHALL BE CONSTRUCTED AS | | | HORIZONTAL ASSEMBLIES IN ACCORDANCE WITH SECTION 711. | | | | | | 1D) 2ND REQUEST. THE RESPONSE INDICATES A FIRE | | | SPRINKLER SYSTEM SHALL BE ADDED TO THE NEW APARTMENT ON | | | RCP SHEET A-104. PLEASE REFER BACK TO THE REQUIREMENTS | | | OF A LEVEL II ALTERATION UNDER 804.2.2. 804.2.2 | | | R-2, IN BUILDINGS WITH OCCUPANCIES IN GROUPS A, B, E, | | | F-1, H, I, M, R-1, R-2, R-4, S-1 AND S-2, WORK AREAS | | | THAT HAVE EXITS OR CORRIDORS SHARED BY MORE THAN ONE | | | TENANT OR THAT HAVE EXITS OR CORRIDORS SERVING AN | | | OCCUPANT LOAD GREATER THAN 30 SHALL BE PROVIDED WITH | | | AUTOMATIC SPRINKLER PROTECTION WHERE ALL OF THE | | | FOLLOWING CONDITIONS OCCUR: | | | (1.) THE WORK AREA IS REQUIRED TO BE PROVIDED WITH | | | AUTOMATIC SPRINKLER PROTECTION IN ACCORDANCE WITH THE | | | FLORIDA BUILDING CODE, BUILDING AS APPLICABLE TO NEW | | | CONSTRUCTION; AND | | | (2.) THE WORK AREA EXCEEDS 50 PERCENT OF THE FLOOR | | | AREA. | | | THIS ADDITION AND RENOVATION MEETS BOTH REQUIREMENTS, | | | THE R2 FIRE AREA NEW AND OLD MUST BE FIRE SPRINKLERED. | | | | | | 1ST ROUND COMMENT. SHEET A-001 UNDER THE HEADING KEY | | | PROJECT DATA INDICATES THE BUILDING IS NON-SPRINKLERED | | | BUILDING. THE 2014 EXISTING BUILDING CODE SECTION | | | 1102.3 FIRE PROTECTION SYSTEMS. EXISTING FIRE AREAS | | | INCREASED BY THE ADDITION SHALL COMPLY WITH CHAPTER 9 | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | 2014 FBC-B 903.2.8 GROUP R. AN AUTOMATIC SPRINKLER | | | SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3 SHALL | | | BE PROVIDED THROUGHOUT ALL BUILDINGS WITH A GROUP R | | | FIRE AREA. | | | | | | 1E) SEMI-COMPLIED. 2ND REVIEW PLEASE REVIEW SHEETS | | | A-202 VERSES A-507. SHEET A-507 IT STILL APPEARS THIS | | | IS AN OPEN STAIR WITH A GUARDRAIL BUT A-107 (2ND FLOOR) | | | & A-202 IT WOULD APPEAR THE OUTSIDE WALL IS A FULLY | | | ENCLOSED WALL WITH AN EXTERIOR EGRESS DOOR AT THE | | | BOTTOM OF THE STAIR WITH AN EXIT DOORWAY? REQUIRING | | | GUARDRAILS ON BOTH SIDES OF THE NEW STAIRWELL. 2014 | | | FBC-B 1009.15 HANDRAILS. STAIRWAYS SHALL HAVE HANDRAILS | | | ON EACH SIDE OF THE STAIR ENCLOSRE AND SHALL COMPLY | | | WITH SECTION 1012. | | | | | | 1ST ROUND COMMENTS. PLEASE PROVIDE A LIFE SAFETY PLAN. | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION 107.3.5 MINIMUM PLAN 107.3.5.1 | | | COMMERCIAL BUILDINGS: | | | | | | STAIRS CONSTRUCTION/GEOMETRY AND PROTECTION | | | GUARDS/ HANDRAILS/ DESIGN LOADS | | | | | | | | | | | | | | | 1F) BUILDING PROVISO/ DEFERRED SUBMITTAL. 107.3.4.2. | | | THE DESIGNER OF RECORD HAS REQUESTED THE EXTERIOR | | | COMPONENTS AND CLADDING TO BE A DEFERRED SUBMITTAL. | | | 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS WHICH | | | ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR | | | TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 2) SEMI-COMPLIED. SHEET A-103 NOW SHOWS THE OPENINGS ON | | | THE NORTH WALL HAVING GLASS BLOCK IN THE OPENINGS, THE | | | PLANS INDICATE THIS AS OPENING # 3, REPLACE WITH FIRE | | | RATED GLASS BLOCK MASONRY. THERE IS NO MENTION AS TO | | | THE REQUIRED FIRE RATING THAT IS REQUIRED. 706.6.1 | | | STEPPED BUILDINGS. | | | | | | 1ST ROUND OF COMMENTS. SHEET A-103 SHOWS A VERTICAL | | | ADDITION. AN ADDITION SHALL NOT CREATE OR EXTEND ANY | | | NONCONFORMITY IN THE EXISTING BUILDING TO WHICH THE | | | ADDITION IS BEING MADE WITH REGARD TO ACCESSIBILITY, | | | STRUCTURAL STRENGTH, FIRE SAFETY, MEANS OF EGRESS, OR | | | THE CAPACITY OF MECHANICAL, PLUMBING, OR ELECTRICAL | | | SYSTEMS. 2014 EXISTING BUILDING CODE. THE NORTH WALL OF | | | THE EXISTING 2 STORY IS LESS THAN 3 FEET FROM THE | | | PROPERTY LINE WALL. THE 2014 FBC-B TABLE 705.8 MAXIMUM | | | AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION | | | DISTANCE AND DEGREE OF OPENING PROTECTION. 0-3 FEET | | | THERE ARE NO OPENINGS ALLOWED. | | | | | | 2014 FBC-B 706.6.1 STEPPED BUILDINGS. WHERE A FIRE WALL | | | SERVES AS AN EXTERIOR WALL FOR A BUILDING AND SEPARATES | | | BUILDINGS HAVING DIFFERENT ROOF LEVELS, SUCH WALL SHALL | | | TERMINATE AT A POINT NOT LESS THAN 30 INCHES ABOVE THE | | | LOWER ROOF LEVEL, PROVIDED THE EXTERIOR WALL FOR A | | | HEIGHT OF 15 FEET ABOVE THE LOWER ROOF IS NOT LESS THAN | | | 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION FROM BOTH | | | SIDES WITH OPENINGS PROTECTED BY FIRE ASSEMBLIES HAVING | | | A FIRE PROTECTION RATING OF NOT LESS THAN 3/4 HOUR. | | | | | | THE DESIGNER OF RECORD MAY CLOSE THESE OPENINGS IN WITH | | | 1 HOUR FIRE RATED CONSTRUCTION AS PER TABLE 602 OF THE | | | FBC-B, INSTALL 3/4 HOUR FIRE RATED GLASS BLOCK, OR A 1 | | | HOUR FIRE SHUTTER ON THE EXTERIOR OF THE WALL. | | | | | | 3) SEMI- COMPLIED. THE DESIGNER OF RECORD NOW INDICATES | | | ON THE PLANS A 2 HOUR RATED CEILING ASSEMBLY BUT THERE | | | IS NO GYPSUM ASSOCIATION, OR UL LISTED ASSEMBLY IN THE | | | PLANS FOR THE RATING OF THE CEILING FOR EITHER 1 OR 2 | | | HOUR. THE CODE ONLY REQUIRES THE CEILING UNDER THE | | | STAIR TO BE 1 HOUR, THE DESIGNER CAN DESIGN TO THE MORE | | | STRINGENT 2 HOUR FIRE REQUIREMENT. | | | | | | 1ST ROUND OF COMMENTS. SHEET A-101 SHOWS UNDER THE | | | ENCLOSED STAIRWELL A CLOSET. THE PLANS DO NOT INDICATE | | | HOW COMPLIANCE WITH SECTION 1009.9.3 WILL BE OBTAINED. | | | 2014 FBC-B 1009.9.3 ENCLOSURES UNDER INTERIOR | | | STAIRWAYS. | | | THE WALLS AND SOFFITS WITHIN ENCLOSED USABLE SPACES | | | UNDER ENCLOSED AND UNENCLOSED STAIRWAYS SHALL BE | | | PROTECTED BY 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION | | | OR THE FIRE-RESISTANCE RATING OF THE STAIRWAY | | | ENCLOSURE, WHICHEVER IS GREATER. ACCESS TO THE ENCLOSED | | | SPACE SHALL NOT BE DIRECTLY FROM WITHIN THE STAIR | | | ENCLOSURE. | | | | | | 4-9) COMPLIED. | | | | | | 10) COMPLIED. EGRESS WINDOWS CASEMENT SIZE 4-10X 3-4. | | | | | | 11) 2ND REQUEST. WINDOW NEXT TO TUB IS INDICATED IN THE | | | RESPONSE SHALL BE CATEGORY II SAFETY GLASS, BUT THIS | | | STATEMENT IS NOT FOUND ON SHEET A-103 WINDOW # 9. ONLY | | | FROSTED GLASS. | | | | | | 1ST ROUND OF COMMENTS. | | | SHEET A-103 THE REAR APARTMENT WITH THE TUB NEXT TO THE | | | EXTERIOR WALL AND WINDOW, PLEASE PROVIDE SILL HEIGHT | | | AND COMPLIANCE WITH: FBC-B 2406.4.5 GLAZING AND WET | | | SURFACES. GLAZING IN WALLS, ENCLOSURES OR, BATHTUBS, | | | SHOWERS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS | | | LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE ANY | | | STANDING OR WALKING SURFACE SHALL BE CONSIDERED A | | | HAZARDOUS LOCATION. THIS SHALL APPLY TO SINGLE GLAZING | | | AND ALL PANES IN MULTIPLE GLAZING. | | | | | | 12)2ND REQUEST. SHEET S-102 THE MEAN ROOF HEIGHT IS | | | GIVEN AT < 15 FEET MEAN ROOF HEIGHT. IN SCALING THE | | | PLANS IT APPEARS THE ROOF HEIGHT IS 22 FEET AND THE TOP | | | OF PARAPET IS 24-9. PLEASE PROVIDE WHERE THE WINDOW, | | | DOOR AND ROOF PRESSURES CAN BE FOUND FOR ZONES 1,2,3,4 | | | & 5. PLEASE PROVIDE THEM IN VASD SINCE THE PRODUCT | | | APPROVALS ARE IN VASD. | | | | | | 1ST ROUND OF COMMENTS. NEITHER THE ELEVATION SHEETS NOR | | | THE STRUCTURAL SHEETS PROVIDE THE WIND DESIGN CRITERIA | | | NOR PRESSURES. | | | 2014 FBC-B 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | 2. RISK CATEGORY. | | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. | | | 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | | M2). | | | TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | | BUILDING. | | | 1609.3.1 WIND SPEED CONVERSION VULT TO VASD. | | | | | | 13) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 14) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-08-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-08-02 |
Time |
16:56 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2016-08-02 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2016-08-02 16:56:22 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16070183 | | | ADD: 518 S. DIXIE HWY. | | | CONT: TBD / TO BE DETERMINED | | | TEL: 954-570-9500 | | | E-MAIL: BRIAN @ TBBG.NET | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. AUGUST 02/ 2016 | | | ACTION: DENIED | | | | | | 1A) SHEET A-001 THE COVERSHEET INDICATES UNDER THE | | | HEADING OF KEY PROJECT DATA THIS BUILDING IS A | | | CONSTRUCTION TYPE (VB) PROTECTED. 107.2.1.3 ADDITIONAL | | | INFORMATION IS REQUIRED. NORMALLY THE TERM PROTECTED IS | | | USED AS A FIRE RATING OF STRUCTURAL MEMBERS, AS IN | | | BUILDING TYPE 1A, 1B, IIA, IIIA, IVA OR VA. | | | SEE TABLE 601 FOR FIRE RATINGS OF STRUCTURAL ELEMENTS. | | | | | | 1B) SHEET A-001 UNDER THE KEY PROJECT DATA DOES NOT | | | ADDRESS THE ISSUE OF THE CLOSENESS OF THE 2 BUILDINGS | | | ON THE SAME LOT AND ALLOWABLE OPENINGS VERSES ASSUMED | | | PROPERTY LINES VERSES 503.1.2 BUILDINGS ON THE SAME | | | LOT. FBC-B 503.1.2. | | | | | | 1C) SHEET A-001 UNDER THE HEADING KEY PROJECT DATA DOES | | | NOT LIST THE REQUIREMENTS FOR SEPARATING OCCUPANCIES | | | WITH HORIZONTAL FIRE BARRIER REQUIREMENTS. SHEET A-101 | | | INDICATES 1 HOUR SEPARATION. SEE FBC-B SECTION 707.3.10 | | | FIRE AREAS. THE FIRE BARRIERS OR HORIZONTAL ASSEMBLIES, | | | OR BOTH. THE FIRE BARRIERS OR HORIZONTAL ASSEMBLIES, OR | | | BOTH, SEPARATING FIRE AREAS OF MIXED OCCUPANCIES SHALL | | | HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN THE | | | HIGHEST VALUE INDICATED IN TABLE 707.3.10 FOR THE | | | OCCUPANCIES UNDER CONSIDERATION, 2 HOUR FIRE RATING. | | | | | | 420.3 HORIZONTAL SEPARATION. FLOOR ASSEMBLIES | | | SEPARATING DWELLING UNITS IN THE SAME BUILDINGS, FLOOR | | | ASSEMBLIES SEPARATING SLEEPING UNITS IN THE SAME | | | BUILDING AND FLOOR ASSEMBLIES SEPARATING DWELLING OR | | | SLEEPING UNITS FROM OTHER OCCUPANCIES CONTIGUOUS TO | | | THEM IN THE SAME BUILDING SHALL BE CONSTRUCTED AS | | | HORIZONTAL ASSEMBLIES IN ACCORDANCE WITH SECTION 711. | | | | | | 1D) SHEET A-001 UNDER THE HEADING KEY PROJECT DATA | | | INDICATES THE BUILDING IS NON-SPRINKLERED BUILDING. THE | | | 2014 EXISTING BUILDING CODE SECTION 1102.3 FIRE | | | PROTECTION SYSTEMS. EXISTING FIRE AREAS INCREASED BY | | | THE ADDITION SHALL COMPLY WITH CHAPTER 9 OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | 2014 FBC-B 903.2.8 GROUP R. AN AUTOMATIC SPRINKLER | | | SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3 SHALL | | | BE PROVIDED THROUGHOUT ALL BUILDINGS WITH A GROUP R | | | FIRE AREA. | | | | | | 1E) PLEASE PROVIDE A LIFE SAFETY PLAN. 2014 FLORIDA | | | BUILDING CODE W 2014 WEST PALM BEACH AMENDMENTS TO THE | | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION | | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | | | | | | | THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING | | | OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA | | | AND DOCUMENTS A LIFE SAFETY FLOOR PLAN WITH: | | | OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: | | | OCCUPANCY LOAD | | | GROSS | | | NET | | | MEANS OF EGRESS | | | EXIT ACCESS | | | EXIT | | | EXIT DISCHARGE | | | STAIRS CONSTRUCTION/GEOMETRY AND PROTECTION | | | GUARDS/ HANDRAILS/ DESIGN LOADS | | | DOORS PROVIDE DOOR SCHEDULE | | | EMERGENCY LIGHTING AND EXIT SIGNS | | | | | | 1F) THE DESIGNER OF RECORD HAS REQUESTED THE EXTERIOR | | | COMPONENTS AND CLADDING TO BE A DEFERRED SUBMITTAL. | | | 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS WHICH | | | ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR | | | TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 2) SHEET A-103 SHOWS A VERTICAL ADDITION. AN ADDITION | | | SHALL NOT CREATE OR EXTEND ANY NONCONFORMITY IN THE | | | EXISTING BUILDING TO WHICH THE ADDITION IS BEING MADE | | | WITH REGARD TO ACCESSIBILITY, STRUCTURAL STRENGTH, FIRE | | | SAFETY, MEANS OF EGRESS, OR THE CAPACITY OF MECHANICAL, | | | PLUMBING, OR ELECTRICAL SYSTEMS. 2014 EXISTING BUILDING | | | CODE. THE NORTH WALL OF THE EXISTING 2 STORY IS LESS | | | THAN 3 FEET FROM THE PROPERTY LINE WALL. THE 2014 FBC-B | | | TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS | | | BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING | | | PROTECTION. 0-3 FEET THERE ARE NO OPENINGS ALLOWED. | | | | | | 2014 FBC-B 706.6.1 STEPPED BUILDINGS. WHERE A FIRE WALL | | | SERVES AS AN EXTERIOR WALL FOR A BUILDING AND SEPARATES | | | BUILDINGS HAVING DIFFERENT ROOF LEVELS, SUCH WALL SHALL | | | TERMINATE AT A POINT NOT LESS THAN 30 INCHES ABOVE THE | | | LOWER ROOF LEVEL, PROVIDED THE EXTERIOR WALL FOR A | | | HEIGHT OF 15 FEET ABOVE THE LOWER ROOF IS NOT LESS THAN | | | 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION FROM BOTH | | | SIDES WITH OPENINGS PROTECTED BY FIRE ASSEMBLIES HAVING | | | A FIRE PROTECTION RATING OF NOT LESS THAN 3/4 HOUR. | | | | | | THE DESIGNER OF RECORD MAY CLOSE THESE OPENINGS IN WITH | | | 1 HOUR FIRE RATED CONSTRUCTION AS PER TABLE 602 OF THE | | | FBC-B, INSTALL 1 HOUR FIRE RATED GLASS BLOCK, OR A 1 | | | HOUR FIRE SHUTTER ON THE EXTERIOR OF THE WALL. | | | | | | 3) SHEET A-101 SHOWS UNDER THE ENCLOSED STAIRWELL A | | | CLOSET. THE PLANS DO NOT INDICATE HOW COMPLIANCE WITH | | | SECTION 1009.9.3 WILL BE OBTAINED. 2014 FBC-B 1009.9.3 | | | ENCLOSURES UNDER INTERIOR STAIRWAYS. | | | THE WALLS AND SOFFITS WITHIN ENCLOSED USABLE SPACES | | | UNDER ENCLOSED AND UNENCLOSED STAIRWAYS SHALL BE | | | PROTECTED BY 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION | | | OR THE FIRE-RESISTANCE RATING OF THE STAIRWAY | | | ENCLOSURE, WHICHEVER IS GREATER. ACCESS TO THE ENCLOSED | | | SPACE SHALL NOT BE DIRECTLY FROM WITHIN THE STAIR | | | ENCLOSURE. | | | | | | 4) SHEET A-101, A-103 & A-104 ALL SHOW A NEW EXTERIOR | | | STAIR. THE PLANS DO NOT SHOW COMPLIANCE WITH SECTION | | | 1026 OF THE 2014 FBC-B. 1026.6 EXTERIOR STAIRWAY AND | | | RAMP PROTECTION. | | | EXTERIOR EXIT STAIRWAYS AND RAMPS SHALL BE SEPARATED | | | FROM THE INTERIOR OF THE BUILDING AS REQUIRED IN | | | SECTION 1022.2. OPENINGS SHALL BE LIMITED TO THOSE | | | NECESSARY FOR EGRESS FROM NORMALLY OCCUPIED SPACES. | | | PLEASE ALSO SEE THE 2012 IBC COMMENTARY 1026.6 AND | | | FIGURE 1026.6(1) FOR ALLOWABLE OPENINGS AND REQUIRED | | | FIRE RATINGS. PLEASE NOTE THIS AFFECTS ALL OPENINGS 1ST | | | & 2ND FLOORS THAT ARE WITHIN 10 FEET OF THE STAIR& | | | LANDINGS ON BOTH BUILDINGS!!!!! | | | | | | 5) SHEET A-101: THE 2ND STORY R2 OCCUPANCY EGRESS STAIR | | | OPENS SWINGING OUT OVER THE PROPERTY LINE. | | | 3202.2 ENCROACHMENTS ABOVE GRADE AND BELOW 8 FEET IN | | | HEIGHT. DOORS AND WINDOWS SHALL NOT OPEN OR PROJECT | | | INTO THE PUBLIC RIGHT-OF-WAY. | | | | | | 6) SHEET A-101 THE NEW PROPOSED DELI DOES NOT SHOW ANY | | | EGRESS DOORS THAT OPEN ONTO DIXIE HWY. THERE IS A PAIR | | | OF DOORS OUT THE BACK OF THE PROPOSED DELI BUT WOULD | | | NEED TO MEET THE REQUIREMENTS FOR EGRESS COURTS, | | | SECTION FBC-B 1027.4.(1-5). | | | | | | 7) SHEET A-103 SHOWS A WALL TYPE LEGEND WITH VARIOUS UL | | | LISTINGS. PLEASE PROVIDE THE WHOLE UL LISTING SO THE | | | INSPECTORS WILL HAVE DOCUMENTATION IN THE FIELD WHAT | | | MAKES UP THE WALL ASSEMBLY. 703.2 FIRE-RESISTANCE | | | RATINGS. | | | | | | 8) THE 2ND FLOOR CORRIDOR WALLS WILL NEED TO SHOW | | | COMPLIANCE WITH 2014 FBC-B 1018.6 CORRIDOR CONTINUITY. | | | FIRE-RESISTANCE-RATED CORRIDORS SHALL BE CONTINUOUS | | | FROM THE POINT OF ENTRY TO AN EXIT, AND SHALL NOT BE | | | INTERRUPTED BY INTERVENING ROOMS. WHERE THE PATH OF | | | EGRESS TRAVEL WITHIN A FIRE-RESISTANCE-RATED CORRIDOR | | | TO THE EXIT INCLUDES TRAVEL ALONG UNENCLOSED EXIT | | | ACCESS STAIRWAYS OR RAMPS, THE FIRE RESISTANCE-RATING | | | SHALL BE CONTINUOUS FOR THE LENGTH OF THE STAIRWAY OR | | | RAMP AND FOR THE LENGTH OF THE CONNECTING CORRIDOR ON | | | THE ADJACENT FLOOR LEADING TO THE EXIT. | | | | | | 9) SHEET A-105 SHOWS ROOF TOP EQUIPMENT ON THE ROOF OF | | | THE SECOND STORY PLEASE SHOW COMPLIANCE WITH: FBC-B | | | 1509.6.4 EQUIPMENT AND APPLIANCES ON ROOFS OR ELEVATED | | | STRUCTURES. WHERE EQUIPMENT AND APPLIANCES REQUIRING | | | ACCESS ARE INSTALLED ON ROOFS OR ELEVATED STRUCTURES AT | | | A HEIGHT EXCEEDING 16 FEET (4877 MM), SUCH ACCESS SHALL | | | BE PROVIDED BY A PERMANENT APPROVED MEANS OF ACCESS, | | | THE EXTENT OF WHICH SHALL BE FROM GRADE OR FLOOR LEVEL | | | TO THE EQUIPMENT AND APPLIANCES? LEVEL SERVICE SPACE. | | | SUCH ACCESS SHALL NOT REQUIRE CLIMBING OVER | | | OBSTRUCTIONS GREATER THAN 30 INCHES (762 MM) HIGH OR | | | WALKING ON ROOFS HAVING A SLOPE GREATER THAN 4 UNITS | | | VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE). | | | PERMANENT LADDERS INSTALLED FOR ROOF TOP ACCESS. | | | | | | 10A) SHEET A-201 & A-202 PLEASE PROVIDE THE CLEAR | | | OPENING SIZE FOR THE WINDOWS (VENT) FOR COMPLIANCE | | | WITH: FBC-B 1029.2 MINIMUM SIZE. EMERGENCY ESCAPE AND | | | RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING | | | OF 5.7 SQUARE FEET. | | | | | | 10B) FBC-B 1029.2.1 MINIMUM DIMENSIONS. THE MINIMUM NET | | | CLEAR OPENING HEIGHT DIMENSION SHALL BE 24 INCHES (610 | | | MM). THE MINIMUM NET CLEAR OPENING WIDTH DIMENSION | | | SHALL BE 20 INCHES (508 MM). THE NET CLEAR OPENING | | | DIMENSIONS SHALL BE THE RESULT OF NORMAL OPERATION OF | | | THE OPENING. | | | | | | 10C) FBC-B 1029.3 MAXIMUM HEIGHT FROM FLOOR. EMERGENCY | | | ESCAPE AND RESCUE OPENINGS SHALL HAVE THE BOTTOM OF THE | | | CLEAR OPENING NOT GREATER THAN 44 INCHES (1118 MM) | | | MEASURED FROM THE FLOOR. | | | | | | 11) SHEET A-103 THE REAR APARTMENT WITH THE TUB NEXT TO | | | THE EXTERIOR WALL AND WINDOW, PLEASE PROVIDE SILL | | | HEIGHT AND COMPLIANCE WITH: FBC-B 2406.4.5 GLAZING AND | | | WET SURFACES. GLAZING IN WALLS, ENCLOSURES OR, | | | BATHTUBS, SHOWERS WHERE THE BOTTOM EXPOSED EDGE OF THE | | | GLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY | | | ABOVE ANY STANDING OR WALKING SURFACE SHALL BE | | | CONSIDERED A HAZARDOUS LOCATION. THIS SHALL APPLY TO | | | SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING. | | | | | | 12) NEITHER THE ELEVATION SHEETS NOR THE STRUCTURAL | | | SHEETS PROVIDE THE WIND DESIGN CRITERIA NOR PRESSURES. | | | 2014 FBC-B 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | 2. RISK CATEGORY. | | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. | | | 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | | M2). | | | TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | | BUILDING. | | | 1609.3.1 WIND SPEED CONVERSION VULT TO VASD. | | | | | | 13) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 14) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2017-05-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-05-10 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-05-10 |
Time |
12:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-12-01 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2016-12-01 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2016-12-01 |
Time |
10:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-07-13 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-07-13 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-07-12 |
Time |
18:50 |
Sent To |
|
|
| Notes |
| 2016-07-13 15:10:07 | 1ST ELECTRICAL REVIEW NOTES | | | REVIEWED FOR COMPLIANCE WITH: | | | 5TH EDITION FBC 2014 & NFPA 70 2011 (NEC) | | | | | | 1. PER FBC-B SECTION 1006.1 YOU ARE REQUIRED TO HAVE | | | ILLUMINATION FOR THE MEANS OF EGRESS. THIS ILLUMINATION | | | SHALL BE PROVIDED WITH EMERGENCY BACK-UP POWER AS | | | INDICATED IN FBC-B SECTION 1006.3. THIS INCLUDES BOTH | | | EXIT STAIRS AND ALL THE WAY TO THE PUBLIC WAY. | | | 2. FBC-EX SECTION 1101.2: THE EXTENT OF ALTERATIONS | | | BEING CONDUCTED PROMOTES ADDITIONAL LIFE SAFETY | | | REQUIREMENTS FOR FIRE SPRINKLER AND FIRE ALARM SYSTEMS. | | | SEE FIRE REVIEW FOR FURTHER DETAILS. | | | 3. NEC 110.26(D): ILLUMINATION SHALL BE PROVIDED ABOUT | | | ELECTRICAL EQUIPMENT. THIS MEANS THAT YOU SHALL PROVIDE | | | LIGHTING ADJACENT TO THE ELECTRICAL PANEL OF UNITS B & | | | C. | | | 4. PER FBC-B 714.3.2 EXCEPTIONS: 1.1 UNLESS YOU HAVE | | | SOLID NONCOMMUNICATING PARTITIONS, ALL ELECTRICAL BOXES | | | IN 2 HR. RATED WALLS SHALL BE PROTECTED WITH LISTED | | | FIRE STOPPING MATERIAL. | | | 5. NOTE WHETHER UNDER SEPARATE PERMIT OR OTHERWISE, THE | | | SERVICE CHANGE HAS TO BE MADE A PART OF THIS PROJECT AS | | | THE EXISTING SERVICE IS NONCOMPLIANT. | | | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | | GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2017-05-03 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-05-03 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-05-03 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2017-05-03 11:59:25 | 518 SOUTH DIXIE HIGHWAY | | | PERMIT #16070183 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | SHEET C-1: PER NFPA 24 SECTION 6.2.1 THE BACKFLOW | | | PREVENTER SHALL BE INSTALLED IN A FIRE-RATED ROOM | | | ACCESSIBLE FROM THE EXTERIOR. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-02-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-02-15 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2017-02-15 10:20:08 | 518 SOUTH DIXIE HIGHWAY | | | PERMIT #16070183 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | FIRE PROTECTION SPRINKLER PLANS REFERENCE THE CIVIL | | | PLANS FOR THE NEW UNDERGROUND FIRE MAIN AND BACKFLOW | | | PREVENTER; HOWERVER, NO CIVIL PLANS WERE SUBMITTED WITH | | | THIS DRAWING SET. | | | | | | FIRE SPRINKLER SYSTEM (BACKFLOW PREVENTER, FLOW | | | SWITCHES, TAMPER SWITCHES, MONITORING PANEL) NEEDS TO | | | BE COORDINATED WITH THE ELECTRICAL DESIGN. | | | | | | FIRE SPRINKLER SYSTEM SHALL BE MONITORED FOR CENTRAL | | | STATION SERVICE. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2016-12-02 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2016-12-02 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2016-12-02 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2016-12-02 15:11:07 | 518 SOUTH DIXIE HIGHWAY | | | PERMIT #16070183 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | THE PROPOSED TWO-FLOOR REHABILITATION OF THIS BUILDING | | | IS EXTENSIVE AND INCLUDES NEW ROOF MEMBRANES/CAPS, | | | WINDOW INFILL AND REPLACEMENT, STRUCTURAL WALL INFILL | | | AND REMOVAL, NEW EXIT DOORS, NEW FIRE RATED FLOOR | | | ASSEMBLY, ETC. IN MY OPINION, THIS SCOPE OF WORK | | | EXCEEDS 50% OF THE AREA OF THE BUILDING AND THEREFORE | | | WOULD REQUIRE SPRINKLERS TO PROTECT THE ENTIRE SECOND | | | FLOOR SEEING THAT ALL NEW APARTMENTS REQUIRE THE ENTIRE | | | BUILDING TO BE PROTECTED THROUGHOUT BY AN APPROVED, | | | SUPERVISED AUTOMATIC SPRINKLER SYSTEM PER SECTION | | | 30.3.5. ADDITIONALLY, THE NEWLY CREATED APARTMENT WILL | | | NOW SHARE EGRESS WITH THE EXISTING APARTMENTS. I | | | BELIEVE THE FOLLOWING SECTIONS SUPPORT MY OPINION: | | | | | | NFPA 101 SECTION 43.5.2.3 WHERE THE TOTAL AREA OF ALL | | | THE REHABILITATION WORK AREAS INCLUDED IN A | | | MODIFICATION EXCEEDS 50 PERCENT OF THE AREA OF THE | | | BUILDING, THE WORK SHALL BE CONSIDERED AS A | | | RECONSTRUCTION AND SHALL COMPLY WITH THE REQUIREMENTS | | | OF SECTION 43.6 FOR THE APPLICABLE OCCUPANCY, UNLESS | | | OTHERWISE SPECIFIED IN 43.5.2.4. | | | | | | NFPA 101 SECTION 43.6.4.1 IN A BUILDING WITH | | | REHABILITATION WORK AREAS INVOLVING OVER 50 PERCENT OF | | | THE AGGREGATE BUILDING AREA, AUTOMATIC SPRINKLER | | | SYSTEMS SHALL BE PROVIDED ON THE HIGHEST FLOOR | | | CONTAINING A REHABILITATION WORK AREA AND ON ALL FLOORS | | | BELOW IN ACCORDANCE WITH THE REQUIREMENTS OF OTHER | | | SECTIONS OF THIS CODE APPLICABLE TO NEW CONSTRUCTION | | | FOR THE OCCUPANCY. | | | | | | NFPA 101 SECTION 43.8.3 FIRE PROTECTION SYSTEMS. IN | | | OTHER THAN ONE- AND TWOFAMILY DWELLINGS, EXISTING | | | COMPARTMENT AREAS WITHOUT AN APPROVED SEPARATION FROM | | | THE ADDITION SHALL BE PROTECTED BY AN APPROVED | | | AUTOMATIC SPRINKLER SYSTEM WHERE THE COMBINED AREAS | | | WOULD BE REQUIRED TO BE SPRINKLERED BY THE PROVISIONS | | | APPLICABLE TO NEW CONSTRUCTION FOR THE OCCUPANCY. | | | | | | NFPA 101 TABLE 30.3.2.1.1 REQUIRES THE SECOND FLOOR | | | WASHER/DRYER LAUNDRY TO BE PROTECTED BY AUTOMATIC FIRE | | | SPRINKLERS OR BE SEPARATED FROM THE CORRIDOR WITH A | | | 1-HOUR FIRE BARRIER. | | | | | | THE NEWLY CREATED ENCLOSED EXIT STAIR IS NOT INCLUDED | | | IN THE MEPF DESIGN SHOWING LIGHTING, EMERGENCY | | | LIGHTING, FIRE SPRINKLERS ETC. | | | | | | THE FIRST FLOOR GROCERY/CONVENIENCE STORE LACKS | | | BUILDOUT DETAIL. IS THIS SPACE INTENDED TO BE A SHELL | | | SPACE WITHOUT OCCUPANCY? | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2016-07-14 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2016-07-14 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2016-07-14 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2016-07-14 13:18:21 | 518 SOUTH DIXIE HIGHWAY | | | PERMIT #16070183 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | NOTE: UNLESS NOTED OTHERWISE, ALL FIRE/LIFE SAFETY | | | REVIEW COMMENTS REFERENCE NFPA 101-THE LIFE SAFETY CODE | | | (2012 EDITION WITH FLORIDA AMENDMENTS.) | | | | | | GENERARL: THE BUILDING IS FUNCTIONING AS A MULTIUSE | | | OCCUPANCY. INDICATE IF THE BUILDING IS DESIGNED FOR | | | MIXED USE (NON-SEPARATED) OR SEPARATED USE PER SECTION | | | 6.1.14.2.1 OF NFPA 101 FLORIDA EDITION 2012. FOR | | | NON-SEPARATED MIXED USE OCCUPANCIES, THE MOST STRINGENT | | | FIRE AND LIFE SAFETY REQUIREMENTS OF EACH OCCUPANCY | | | SHALL APPLY TO THE BUILDING. | | | | | | GENERAL: PROVIDE A LIFE SAFETY PLAN SHOWING ALL | | | OCCUPANCY TYPES, OCCUPANT LOADS, FIRE RATED WALLS, | | | EXITS, EXIT SIGNS, EMERGENCY LIGHTING, TRAVEL | | | DISTANCES, COMMON PATH OF TRAVEL ETC. | | | | | | GENERAL: PROVIDE A DETAILED SITE. | | | | | | GENERAL: PROVIDE AN EXTERIOR KEY SAFE TO ALLOW | | | EMERGENCY RESPONDERS NON-FORCIBLE ENTRY INTO THE | | | BUILDING DURING NON-BUSINESS HOURS. A KEY SAFE CAN BE | | | ORDERED FROM WWW.KNOXBOX.COM. | | | | | | GENERAL: STRUCTURES WITH LIGHT FRAME FLOOR/ROOF TRUSS | | | CONSTRUCTION SHALL BE IDENTIFIED WITH A SIGN AFFIXED TO | | | THE BUILDING. THE SIGN SHALL FEATURE A MALTESE CROSS | | | 8-INCHES WIDE AND 8-INCHES TALL AND BE OF A BRIGHT RED | | | REFLECTIVE COLOR AND BEAR THE APPROPRIATE LETTER R/F/RF | | | DESIGNATION PER FLORIDA STATUTE 633.027 AND FLORIDA | | | ADMINISTRATIVE CODE 69A-60.0081. | | | | | | GENERAL: PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT | | | DOORS WITH EXIT SIGNS. | | | | | | GENERAL: PER NPFA 1 SECTION 8.3.2.4, EACH FIRE BARRIER | | | SHALL BE PERMANENTLY IDENTIFIED WITH SIGNS OR | | | STENCILING READING FIRE BARRIER-PROTECT ALL OPENINGS. | | | CHARACTERS SHALL BE AT LEAST 4-INCHES IN HEIGHT AND | | | HALF-INCH IN WIDTH. IDENTIFICATION SHALL BE SPACED NOT | | | MORE THAN 15 FEET ON CENTER. | | | | | | GENERAL: PER SECTION 7.2.2.6.3 THE OUTSIDE STAIRS MAY | | | NEED TO BE PROTECTED FROM FIRE EXPOSURE DEPENDING UPON | | | OPENING PROTECTIVES AND SPRINKLER PROTECTION OF | | | ADJACENT BUILDING. | | | | | | GENERARL: NO STAIR OR HANDRAIL DETAILS SUBMITTED. | | | HANDRAILS ARE REQUIRED ON BOTH SIDES OF THE STAIR. | | | HANDRAILS SHALL BE LOCATED NOT LESS THAN 34 INCHES AND | | | NOT MORE THAN 38 INCHES ABOVE THE SURFACE OF THE TREAD, | | | MEASURED VERTICALLY TO THE TOP OF THE RAIL FROM THE | | | LEADING EDGE OF THE TREAD. HANDRAIL ENDS SHALL BE | | | RETURNED TO THE WALL OR FLOOR OR SHALL TERMINATE AT | | | NEWEL POSTS. HANDRAIL CROSS SECTION SHALL HAVE A | | | DIAMETER OF NOT LESS THAN 1.25 INCHES AND NOT MORE THAN | | | 2 INCHES. STAIR RISERS SHALL BE BETWEEN 4 INCHES AND 7 | | | INCHES IN HEIGHT. STAIRS SHALL BE SLIP RESISTANT AND | | | HAVE A MINIMUM TREAD DEPTH OF 11 INCHES AND PREVENT THE | | | ACCUMULATION OF WATER. | | | | | | SHEET A-001: PROJECT DATA INDICATES THIS BUILDING IS | | | NOT PROTECTED BY AUTOMATIC FIRE SPRINKLERS. ALL NEW | | | APARTMENTS REQUIRE THE ENTIRE BUILDING TO BE PROTECTED | | | THROUGHOUT BY AN APPROVED, SUPERVISED AUTOMATIC | | | SPRINKLER SYSTEM PER SECTION 30.3.5. PER SECTION | | | 43.8.1.2, AN ADDITION SHALL NOT CREATE OR EXTEND ANY | | | NONCONFORMITY WITH REGARD TO FIRE SAFETY OR THE MEANS | | | OF EGRESS IN THE EXISTING BUILDING FOR WHICH THE | | | ADDITION IS CONSTRUCTED. FOR ISSUANCE OF A GENERAL | | | BUILDING PERMIT, SECTION 105.3.1.2(2) OF THE FLORIDA | | | BUILDING CODE REQUIRES SEALED FIRE PROTECTION | | | CONSTRUCTION DOCUMENTS FOR THE DESIGN OR ALTERATION OF | | | 50 OR MORE AUTOMATIC FIRE SPRINKLERS. PER FLORIDA | | | ADMINISTRATIVE CODE SECTION 61G15-32.004, FIRE | | | PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | | | | SHEET A-103: NO DOOR SCHEDULE PROVIDED. PER SECTION | | | 30.3.6.2.1 DOORS THAT OPEN ONTO EXIT ACCESS CORRIDORS | | | SHALL HAVE NOT LESS THAN A 20-MINUTE FIRE PROTECTION | | | RATING AND SHALL BE SELF CLOSING AND SELF LATCHING. | | | | | | SHEET E1.1 & E1.2: NO INTERIOR OR EXTERIOR STAIR | | | LIGHTING PROVIDED. PER SECTION 7.8.1.3 THE FLOORS AND | | | OTHER WALKING SURFACES WITHIN AN EXIT AND WITHIN THE | | | PORTIONS OF THE EXIT ACCESS AND EXIT DISCHARGE | | | DESIGNATED SHALL BE ILLUMINATED AS FOLLOWS: | | | (1) DURING CONDITIONS OF STAIR USE, THE MINIMUM | | | ILLUMINATION FOR STAIRS SHALL BE AT LEAST 10 FT-CANDLE | | | (108 LUX), MEASURED AT THE WALKING SURFACES. | | | | | | A THOROUGH AND COMPLETE PLAN REVIEW CANNOT BE COMPLETED | | | AT THIS TIME DUE TO LACK OF INFORMATION SUBMITTED ON | | | THE PLANS. ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED DURING PLAN RESUBMISSION. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-05-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-04-28 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-03-03 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2017-03-03 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-01-27 |
Time |
13:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-12-19 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-12-19 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-11-29 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-08-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-08-17 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-07-06 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2017-05-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-05-10 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-10 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2017-05-10 09:09:21 | PALM BEACH COUNTY IMPACT FEE OFFICE | | | DATE: 05/09/2017 | | | MU-17-12820 | | | SQUARE FEET: 841 SQ. FT. | | | AMOUNT PAID: 7146.85 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2017-02-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-02-01 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-02-01 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2017-02-01 17:27:06 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2016-12-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-12-03 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-12-03 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2016-12-03 11:03:27 | IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2016-08-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-08-02 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-08-02 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2016-08-02 16:56:34 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-02-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-02-02 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-02-02 |
Time |
14:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-12-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-12-05 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-12-05 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2016-12-05 11:24:59 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #16070183 | | | 12/5/16 | | | | | | 1) THE ENERGYGAUGE COMPLIANCE SUBMITTAL SHOWS | | | COMPLIANCE DATA FOR ONLY ONE SYSTEM, HOWEVER THE | | | EQUIPMENT SCHEDULE ON MO.2 SHOWS 6 SYSTEMS. | | | | | | 2) THERE IS MISSING INFORMATION ON PAGE 1 OF THE | | | ENERGYGAUGE SUBMITTAL: OWNER'S NAME, BUILDER'S NAME, | | | PERMIT OFFICE, JURISDICTION, AND SIGNATURE OF THE | | | OWNER/AGENT. SEE ALSO PAGE 2 FOR MISSING INFORMATION | | | REQUIRED UNDER PROJECT. | | | | | | 3) THE SPECS FOR VENTING THE DRYER ON MO.2 ARE NOT | | | LEGIBLE- PLEASE PROVIDE CLEAR LEGIBLE SPECIFICATIONS. | | | | | | 4) PROVIDE GUARDS AT THE ROOF EDGES WHERE ROOFTOP | | | EQUIPMENT IS CLOSER THAN THE MINIMUM 10' REQUIRED. SEE | | | 1ST REVIEW COMMENT #8. | | | | | | 5) CLARIFY HOW OUTDOOR AIR WILL BE PROVIDED TO THE | | | APARTMENTS. THERE ARE NO CALCULATIONS OR METHODS SHOWN | | | ON THE PLANS- SEE SECTION 401.2. | | | | | | 6) THE MECHANICAL ENGINEER OF RECORD HAS INDICATED WIND | | | LOAD ENGINNERING AND THE NOA FOR INSTALLATION OF THE | | | ROOFTOP CONDENSERS IS TO BE A DEFERRED SUBMITTAL. | | | PLEASE NOTE THE FOLLOWING: | | | | | | 1) DEFERRED SUBMITTAL: 107.3.4.2 DEFERRED SUBMITTALS. | | | FOR THE PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS | | | ARE DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE | | | NOT SUBMITTED AT THE TIME OF THE | | | APPLICATION AND THAT ARE TO BE SUBMITTED TO THE | | | BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL | | | OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF | | | THE BUILDING OFFICIAL. THE REGISTERED DESIGN | | | PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE | | | DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR | | | REVIEW BY THE BUILDING OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | 2) DEFERRED SUBMITTAL. 2010 FBC 107.3.4.1 PRODUCT | | | APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY THE | | | DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-07-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-07-15 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-07-15 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2016-07-15 10:11:59 | 1ST REVIEW MECHANICAL | | | PERMIT #16070183 | | | 7/15/16 | | | | | | 1) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | | NEW MINI-SPLIT SYSTEMS- SECTION C403.2.1 FBC-14 ENERGY | | | CONSERVATION. | | | | | | 2) PROVIDE ENERGY CALCULATIONS IN COMPLIANCE WITH | | | SECTION C101.4.3 & C401.2 FBC-14 ENERGY CONSERVATION. | | | | | | 3) PROVIDE AN EXHAUST VENTILATION CALCULATION FOR THE | | | DRYER AND SUBMIT MANUFACTURER'S SPECIFICATIONS- SECTION | | | 504.5, 504.6.4. INDICATE THE TYPE OF EXHAUST DUCT WORK | | | AND GAUGE OF STEEL | | | | | | 4) PROVIDE UL LISTED FIRESTOPPING ASSEMBLIES FOR AC | | | REFRIGERANT AND CONDENSATE PIPING PENETRATING | | | FIRE-RATED FLOOR/CEILING AND WALL ASSEMBLIES. | | | | | | 5) INDICATE THE TYPE AND THICKNESS OF REFRIGERANT AND | | | CONDENSATE PIPING INSULATION ON THE PLAN, AND PROVIDE A | | | SUBMITTAL. | | | | | | 6) M0.1: PROVIDE THE WIND LOAD DESIGN CRITERIA AND | | | COMPLETE DETAILS FOR ATTACHMENT AND ANCHORING OF THE | | | CONDENSER UNITS AND ROOF STAND. SUBMIT A FL. PRODUCT | | | APPROVAL FOR THE STAND WITH APPROVAL SIGNATURE BY THE | | | DESIGN PROFESSIONAL OF RECORD. PLEASE CIRCLE, | | | HIGHLIGHT, OR OTHERWISE MARK ALL APPLICABLE DETAILS, | | | NOTES, DESIGN PRESSURES SHOWN ON THE DOCUMENT- SECTION | | | 301.15. | | | | | | 7) IT APPEARS THAT A PERMANENT LADDER WILL BE REQUIRED | | | TO PROVIDE ACCESS TO THE ROOFTOP MECHANICAL EQUIPMENT. | | | REFER TO SECTION 306.5 AND SHOW THE LOCATION OF THE | | | LADDER, AND PROVIDE CONSTRUCTION DETAILS. | | | | | | 8) THERE ARE NO DIMESIONS ON THE ELEVATION DRAWINGS OR | | | PARAPET SECTIONS TO INDICATE THE HEIGHT OF THE PARAPET | | | ABOVE THE FINISHED ROOF SURFACE. PLEASE REVIEW AND | | | PROVIDE GUARDS AT THE ROOF EDGES WHERE NECESSARY AS | | | REQUIRED BY SECTION 304.11. | | | | | | 9) CLARIFY HOW ACCESS FOR MAINTENANCE AND REPLACEMENT | | | OF THE DRYER MAKEUP AIR MOTORIZED DAMPER WILL BE | | | PROVIDED- SEE SECTION 306.1. | | | | | | 10) SHEET A-105 SHOWS A MECHANICAL CHASE MOST LIKELY | | | FOR A KITCHEN EXHAUST DUCT. PLEASE NOTE THAT THE DUCT | | | MUST BE INSPECTED BEFORE BEING ENCLOSED IN THE CHASE, | | | AND A UL APPROVED FIRESTOPPING ASSEMBLY WILL BE | | | REQUIRED WHERE THE DUCT EXITS THE BOTTOM OF THE CHASE | | | AT CEILING LEVEL. PLEASE ALSO NOTE THAT GREASE DUCTS | | | REQUIRE AN 18" CLEARANCE TO COMBUSTIBLES PER SECTION | | | 506.3.6. | | | | | | 11) PLEASE PROVIDE A RESPONSE NARRATIVE FROM THE DESIGN | | | PROFESSIONAL ADDRESSING ALL OF THE COMMENTS LISTED | | | ABOVE, A) ALL MECHANICAL EQUIPMENT AND APPLIANCE | | | SUBMITTALS SHALL BEAR THE APPROVAL SIGNATURE OF THE | | | DESIGN PROFESSIONAL OF RECORD. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2017-02-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-02-09 |
Time |
17:48 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-02-09 |
Time |
15:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2016-12-13 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-12-13 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-12-12 |
Time |
17:04 |
Sent To |
|
|
| Notes |
| 2016-12-13 10:29:17 | 2ND REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | | | ORIGINAL COMMENTS: | | | | | | NOT COMPLIED 1) INDICATE THE OCCUPANCY GROUPS ON THE | | | PLAN IN ACCORDANCE WITH CHAPTER 3 OF FBC. | | | | | | NOT COMPLIED 2) SUBMIT AN EXISTING FIRST FLOOR PLAN. | | | WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | NOT COMPLIED 3) SHT. A-103. SHOW THE WIDTH OF THE | | | SHOWERS. COMPLY WITH FPC SEC.417.4 | | | | | | NOT COMPLIED 6) THE BACKFLOW PREVENTERS SHALL BE | | | LOCATED AT THE WATER METERS PER THE CWP CROSS | | | CONNECTION CONTROL MANUAL. | | | NOT COMPLIED 7) THE PLAN CALLS OUT A 2 INCH UNDERGROUND | | | COLD WATER LINE BUT THE LINE IS LABELED AS A CONDENSATE | | | DRAIN. CLARIFY. THERE IS NOTES REMAINING ON CONDENSATE | | | LINE WHICH ARE CALLING IT A COLD WATER LINE. | | | NOT COMPLIED 8) SHT. A101 CALLS OUT FOR THE EXISTING | | | GREASE TRAP TO BE REPLACED OR RELOCATED & SHT.P1.1 | | | INDICATES IT IS TO REMAIN. WHICH IS IT? CLARIFY. | | | | | | NEW COMMENTS: | | | | | | 1. SHT A-101 IS THE BATHROOM EXISTING IF IT IS NEW OR | | | RELOCATED PROVIDE PLUMBING RISER. AND NOTE ON PLAN. WPB | | | AMEND TO FBC 107.3.5.1.3(13) | | | | | | 2. PROVIDE MOUNTING DETAILS FOR GRAB BARS TO COMPLY | | | WITH. FBC ACC 604.5.1/ | | | 604.5.2 /609.4 | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-08-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-08-17 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-08-17 |
Time |
06:10 |
Sent To |
|
|
| Notes |
| 2016-08-17 10:34:01 | 1) INDICATE THE OCCUPANCY GROUPS ON THE PLAN IN | | | ACCORDANCE WITH CHAPTER 3 OF FBC. | | | 2) SUBMIT AN EXISTING FIRST FLOOR PLAN. WPB AMEND. TO | | | FBC SEC. 107.2.1. | | | 3) SHT. A-103. SHOW THE WIDTH OF THE SHOWERS. COMPLY | | | WITH FPC SEC.417.4 | | | 4) ACCESS SHALL BE PROVIDED TO THE SHUTOFF VALVES FOR | | | THE STACKED WASHER/DRYER UNITS. FPC SEC.606.3. | | | 5) SHT.P1.1 - THE PLANS CALL OUT NEW 1 INCH COLD WATER | | | PIPE IN CEILING BUT THE LINE IS LABELED AS A CONDENSATE | | | LINE. THIS OCCURS IN SVERAL PLACES. CLARIFY. | | | 6) THE BACKFLOW PREVENTERS SHALL BE LOCATED AT THE | | | WATER METERS PER THE CWP CROSS CONNECTION CONTROL | | | MANUAL. | | | 7) THE PLAN CALLS OUT A 2 INCH UNDERGROUND COLD WATER | | | LINE BUT THE LINE IS LABELED AS A CONDENSATE DRAIN. | | | CLARIFY. | | | 8) SHT. A101 CALLS OUT FOR THE EXISTING GREASE TRAP TO | | | BE RREPLACED OR RELOCATED & SHT.P1.1 INDICATES IT IS TO | | | REMAIN. WHICH IS IT? CLARIFY. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-08-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
kmartin |
Date |
2017-08-30 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2017-08-17 10:49:59 | PROVISO | | | 1. A MINIMUM OF TWO BICYCLE PARKING SPACES SHALL BE | | | PROVIDED ONSITE FOR NEW UNITS. | | | 2. A MINIMUM TWO CAR PARKING SPACES SHALL BE PROVIDED | | | FOR NEW UNITS. | | | 3. A TROLLEY CONTRIBUTION FEE WILL BE ESTABLISHED AT | | | THE TIME OF CO ISSUANCE. | | | | | | FOR MORE INFORMATION, PLEASE CONTACT KEVIN MARTIN | | | -URBAN DESIGN PLANNER AT [email protected]. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2017-03-03 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-03-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
kmartin |
Date |
2017-03-03 |
Time |
10:36 |
Sent To |
I |
|
| Notes |
| 2017-03-03 10:36:46 | PROVISO: PARKING REQUIREMENTS FOR ADDITIONAL UNITS MUST | | | BE MET BEFORE CERTIFICATE OF OCCUPANCY IS ISSUED. | | | | | | FOR MORE INFORMATION PLEASE CONTACT KEVIN MARTIN, URBAN | | | DESIGN PLANNER AT (561) 822-1426 OR [email protected]. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2016-12-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2016-12-19 |
Time |
|
Sent To |
|
|
| Notes |
| 2016-12-19 14:27:24 | PROVISO: PARKING REQUIREMENTS FOR ADDITIONAL UNITS MUST | | | BE MET BEFORE CERTIFICATE OF OCCUPANCY IS ISSUED. | | | | | | FOR MORE INFORMATION PLEASE CONTACT KEVIN MARTIN, URBAN | | | DESIGN PLANNER AT (561) 822-1426 OR [email protected]. | | 2016-12-13 12:12:12 | ROUTED TO KEVIN MARTIN |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-08-01 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2016-08-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
kmartin |
Date |
2016-08-01 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2016-08-01 11:37:50 | PROVISO: PARKING REQUIREMENTS FOR ADDITIONAL UNITS MUST | | | BE MET BEFORE CERTIFICATE OF OCCUPANCY IS ISSUED. | | | | | | FOR MORE INFORMATION PLEASE CONTACT KEVIN MARTIN, URBAN | | | DESIGN PLANNER AT (561) 822-1426 OR [email protected]. |
|
|
|