| Plan Review Stops For Permit 16070170 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-08-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-08-12 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-08-12 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-07-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-07-12 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-07-12 |
Time |
08:42 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-08-11 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-08-11 |
Time |
19:31 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-08-11 |
Time |
18:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-07-11 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-07-11 |
Time |
19:32 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-07-11 |
Time |
19:27 |
Sent To |
B |
|
| Notes |
| 2016-07-11 19:41:07 | REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | | | | - SINCE LIGHT NICHE IS OF CONDUCTIVE PROPERTIES A # 8 | | | AWG EQUIPMENT GROUNDING CONDUCTOR MUST BE ROUTED IN THE | | | RACEWAY AND A LISTED COMPOUND MUST BE APPLIED TO THE | | | FORMING SHELL LUG TERMINAL FOR THE BONDING CONNECTION | | | PREVENTING DETERIORATING EFFECT OF POOL WATER. NEC | | | 680.23 | | | | | | - ON THE ONE LINE DIAGRAM SPECIFY WHAT SIZE WIRE IS | | | FEEDING THE POOL EQUIPMENT PANEL AND THE OVERCURRENT | | | PROTECTION SIZE COMING FROM THE SERVICE PANEL. FBC 107, | | | NEC 215.5 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2016-07-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-07-20 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-07-20 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2016-07-20 14:26:13 | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-08-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-08-12 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-08-05 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2016-08-05 14:34:53 | RESUB ROUTED TO NJWIRA VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-07-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-07-20 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-07-06 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2016-07-07 10:40:25 | ROUTED TO ZONING |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-07-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-07-20 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-07-20 |
Time |
14:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2016-08-09 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2016-08-09 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-08-08 |
Time |
08:15 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2016-07-11 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2016-07-11 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-07-11 |
Time |
16:26 |
Sent To |
E |
|
| Notes |
| 2016-07-22 08:32:25 | TREE ALTERATION PERMIT NOT REQUIRED AFTER SPEAKING WITH | | | THE OWNER | | 2016-07-11 16:29:20 | 7/11/16- FAILED | | | | | | 1. TREE ALTERATION PERMIT REQUIRED TO REMOVE TREES. | | | 2. 7FT. 7IN. MEETS THE 5FT REAR SETBACK REQUIREMENT. | | | 3. 16FT 6IN MEETS THE 5FT. SIDE SETBACK. | | | 4. FENCE IS ALREADY BUILT. | | | 5. POOL EQUIPMENT IS NOT BUILT 4FT. INTO A SIDE | | | SETBACK. | | | | | | PLEASE CONTACT: | | | NATHAN WIRA | | | (561)822-1442 | | | [email protected] | | | |
|
|