Plan Review Details - Permit 16070170
Plan Review Stops For Permit 16070170
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-08-12 Cont ID  
Sent By cthroop Date 2016-08-12 Time 09:59 Rev Time 0.00
Received By cthroop Date 2016-08-12 Time 09:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-07-12 Cont ID  
Sent By cthroop Date 2016-07-12 Time 08:42 Rev Time 0.00
Received By cthroop Date 2016-07-12 Time 08:42 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-08-11 Cont ID  
Sent By mvaldes Date 2016-08-11 Time 19:31 Rev Time 0.00
Received By mvaldes Date 2016-08-11 Time 18:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-07-11 Cont ID  
Sent By mvaldes Date 2016-07-11 Time 19:32 Rev Time 0.00
Received By mvaldes Date 2016-07-11 Time 19:27 Sent To B
Notes
2016-07-11 19:41:07REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
  
 - SINCE LIGHT NICHE IS OF CONDUCTIVE PROPERTIES A # 8
 AWG EQUIPMENT GROUNDING CONDUCTOR MUST BE ROUTED IN THE
 RACEWAY AND A LISTED COMPOUND MUST BE APPLIED TO THE
 FORMING SHELL LUG TERMINAL FOR THE BONDING CONNECTION
 PREVENTING DETERIORATING EFFECT OF POOL WATER. NEC
 680.23
  
 - ON THE ONE LINE DIAGRAM SPECIFY WHAT SIZE WIRE IS
 FEEDING THE POOL EQUIPMENT PANEL AND THE OVERCURRENT
 PROTECTION SIZE COMING FROM THE SERVICE PANEL. FBC 107,
 NEC 215.5

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2016-07-20 Cont ID  
Sent By gjohnson Date 2016-07-20 Time 14:24 Rev Time 0.00
Received By gjohnson Date 2016-07-20 Time 14:24 Sent To  
Notes
2016-07-20 14:26:13A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE
 REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK.
 PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT
 SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE
 SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC.
 107.2.1.
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-08-12 Cont ID  
Sent By cthroop Date 2016-08-12 Time 09:58 Rev Time 0.00
Received By cthroop Date 2016-08-05 Time 14:34 Sent To  
Notes
2016-08-05 14:34:53RESUB ROUTED TO NJWIRA VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-07-20 Cont ID  
Sent By gjohnson Date 2016-07-20 Time 14:28 Rev Time 0.00
Received By gjohnson Date 2016-07-06 Time 10:39 Sent To  
Notes
2016-07-07 10:40:25ROUTED TO ZONING

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-07-20 Cont ID  
Sent By gjohnson Date 2016-07-20 Time 14:26 Rev Time 0.00
Received By gjohnson Date 2016-07-20 Time 14:26 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2016-08-09 Cont ID  
Sent By njwira Date 2016-08-09 Time 15:36 Rev Time 0.00
Received By njwira Date 2016-08-08 Time 08:15 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2016-07-11 Cont ID  
Sent By njwira Date 2016-07-11 Time 16:26 Rev Time 0.00
Received By njwira Date 2016-07-11 Time 16:26 Sent To E
Notes
2016-07-22 08:32:25TREE ALTERATION PERMIT NOT REQUIRED AFTER SPEAKING WITH
 THE OWNER
2016-07-11 16:29:207/11/16- FAILED
  
 1. TREE ALTERATION PERMIT REQUIRED TO REMOVE TREES.
 2. 7FT. 7IN. MEETS THE 5FT REAR SETBACK REQUIREMENT.
 3. 16FT 6IN MEETS THE 5FT. SIDE SETBACK.
 4. FENCE IS ALREADY BUILT.
 5. POOL EQUIPMENT IS NOT BUILT 4FT. INTO A SIDE
 SETBACK.
  
 PLEASE CONTACT:
 NATHAN WIRA
 (561)822-1442
 [email protected]
  