Plan Review Details - Permit 16070096
Plan Review Stops For Permit 16070096
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-09-12 Cont ID  
Sent By jwitmer Date 2016-09-12 Time 12:29 Rev Time 0.00
Received By jwitmer Date 2016-09-12 Time 11:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-08-05 Cont ID  
Sent By jwitmer Date 2016-08-05 Time 10:54 Rev Time 0.00
Received By jwitmer Date 2016-08-05 Time 09:12 Sent To  
Notes
2016-08-05 10:54:17BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16070096
 ADD: 838 ADAMS ST.
 CONT: LAGASSE POOL CONSTRUCTION
 TEL: 954-587-1000
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 1ST REVIEW
 DATE: FRI. AUGUST 05/2016
 ACTION: DENIED
  
 1) SHEET 2 OF 7 THE LEFT SIDE OF THE SHEET, INFORMATION
 HAS BEEN CUT OFF. 107.2.1.3 ADDITIONAL INFORMATION IS
 REQUIRED.
  
 2) SHEET 3 OF 7 INDICATES THE AREA OF THE POOL TO BE
 1397 SQ. FT./ WHEREAS SHEET A-1.00 SHOWS A SQ. FOOTAGE
 OF 1737 SQ. FT. DISCREPANCY IN PLANS 107.2.1.3
 ADDITIONAL INFORMATION REQUIRED.
  
 3) SHEET A-1.00 FOR THE OCCUPANT LOAD OF THE POOL DECK
 IS 3387 SQ. FT. /30 = 113 OCCUPANTS. PLEASE REVIEW THE
 2014 FBC-B TABLE 1004.1.2 POOL DECKS ARE TAKEN AT 15
 SQ. FT. 3387/15 = 226 OCCUPANTS.
  
 4) SHEET 5 OF 7 SCHEMATIC PLAN WITH NOTES L & M LINES
 TO AND FROM HEATER. PLEASE SUBMIT THE MANUFACTURERS
 SPECIFICATIONS FOR THE POOL HEATER. THE HEATER SHALL
 COMPLY WITH THE 2014 FBC-ENERGY CODE C404.7.
  
 5) PLEASE PROVIDE WHERE COMPLIANCE WITH THE 2014
 FBC-ENERGY CODE C404.7.2 A TIME CLOCK OR OTHER METHOD
 THAT WILL AUTOMATICALLY TURN OFF AND ON THE HEATER.
  
 6) PLEASE ALSO SHOW COMPLIANCE WITH THE 2014 FBC-ENERGY
 CODE HEATED SWIMMING POOLS SHALL BE EQUIPPED WITH A
 VAPOR-RETARDANT COVER ON OR AT THE WATER SURFACE OR A
 LIQUID COVER OR OTHER MEANS PROVEN TO REDUCE HEAT LOSS.
  
 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-09-07 Cont ID  
Sent By mvaldes Date 2016-09-07 Time 19:30 Rev Time 0.00
Received By mvaldes Date 2016-09-07 Time 18:26 Sent To B
Notes
2016-09-08 08:28:49ROUTED TO JW

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-07-21 Cont ID  
Sent By mvaldes Date 2016-07-21 Time 10:22 Rev Time 0.00
Received By mvaldes Date 2016-07-21 Time 08:59 Sent To  
Notes
2016-07-21 10:41:48JOB PERMIT NUMBER: 16070096
 JOB ADDRESS: 838 ADAMS STREET
 WEST PALM BEACH FLORIDA
 DATE: JULY 21 2016
  ELECTRICAL PLAN REVIEW COMMENTS
  
 THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION
 HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF
 THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC,
 (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST
 PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF
 SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED.
  
 - PROVIDE MANUFACTURE SPECS ON ALL ASSOCIATED POOL
 EQUIPMENT SUCH AS HEATERS, POOL LIGHTS, CHLORINATOR,
 MOTOR PUMPS, AND ETC. FBC 107 MINIMUM PLAN REVIEW
 - IN ADDITION TO BONDING THE LIGHT NICHE TO THE
 EQUIPOTENTIAL GRID A # 8 AWG ?INSULATED? EQUIPMENT
 GROUNDING CONDUCTOR SHALL BE RAN INSIDE THE PVC CONDUIT
 EXTENDING DIRECTLY FROM THE FORMING SHELL AND A LISTED
 COMPOUND SHALL BE PLACED ON THE BONDING CONNECTION FOR
 ANY DETERIORATING EFFECT. NEC 680.23(2)(B)
 - IF POOL HEATERS ARE BEING INSTALLED PLEASE MODIFY ONE
 LINE DIAGRAM AND PANEL SCHEDULE IN ADDITION A TIME
 SWITCH CONTROL DEVICE SHALL BE INSTALLED PER FBC E
 SECTION C404.7.2
 - ADD A NOTE REFERENCING BONDING OF POOL WATER NEC
 680.26(C). IF A SEPARATE DEVICE IS BEING INSTALLED A
 MINIMUM OF 9?? SQUARED SURFACE AREA MUST BE COVERED BY
 POOL WATER.
 - SITE LIGHTING SHALL BE UNDER A SEPARATE PERMIT,
 INCLUDE EXTERIOR LIGHTING CONTROLS, PHOTOMETRICS ( FOOT
 CANDLE ILLUMINATION ), WIRE & BREAKER SIZE AND POWER
 SOURCE DIAGRAM.
  
 PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE
 MENTIONED DEFICIENCIES.
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE
 LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE
 STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD
 INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE
 OR ACTION TO SAME.
 ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO THE
 SUBMITTAL AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARISON.
 CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 FBC 2014 5TH ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2016-07-20 Cont ID  
Sent By tklarge Date 2016-07-20 Time 12:15 Rev Time 0.00
Received By tklarge Date 2016-07-20 Time 12:15 Sent To  
Notes
2016-07-20 12:16:27GAS PLAN REVIEW
 A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE
 REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK.
 PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT
 SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE
 SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC.
 107.2.1.
  
 GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL
 GAS SEC. 301.3.
  
 A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-09-20 Cont ID  
Sent By lmarchan Date 2016-09-20 Time 14:49 Rev Time 0.00
Received By lmarchan Date 2016-09-12 Time 09:58 Sent To  
Notes
2016-09-13 09:59:16RESUB ROUTED TO NJWIRA VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-09-12 Cont ID  
Sent By   Date 2016-09-12 Time 12:29 Rev Time 0.00
Received By lmarchan Date 2016-08-22 Time 13:09 Sent To  
Notes
2016-08-23 13:09:20RESUB ROUTED TO NJWIRA VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-08-05 Cont ID  
Sent By jwitmer Date 2016-08-05 Time 10:54 Rev Time 0.00
Received By jwitmer Date 2016-07-05 Time 10:48 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2016-09-20 Cont ID  
Sent By tklarge Date 2016-09-20 Time 06:30 Rev Time 0.00
Received By tklarge Date 2016-09-20 Time 05:52 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2016-09-07 Cont ID  
Sent By tklarge Date 2016-09-07 Time 06:47 Rev Time 0.00
Received By tklarge Date 2016-09-02 Time 06:02 Sent To  
Notes
2016-09-07 06:18:141) SHT. P-1.00 SHOWS THE POOL DRAIN DISCHARGING TO A
 CATCH BASIN.POOL WATER SHALL NOT DRAIN TO THE SANITARY
 OR THE STORM DRAINAGE SYSTEM PER CITY OF WPB CODE OF
 ORDINANCES ART. III, SEC.90-126 (B) (5) & ART. V,
 SEC.90-203 (A). 2ND REQUEST.
 2) THE AREA OF THE POOL ON SHT.A-1.00 IS SSHOWN AS 1737
 SQ. FT. AND SHT.3 SHOWS 1397 SQ. FT. CLARIFY. 2ND
 REQUEST.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-07-20 Cont ID  
Sent By tklarge Date 2016-07-20 Time 12:14 Rev Time 0.00
Received By tklarge Date 2016-07-18 Time 14:17 Sent To  
Notes
2016-07-20 06:39:451) A MINIMUM FOUR FEET HIGH FENCE SHALL SURROUND THE
 EQUIPMENT AREA PER 2014 FBC SEC. 454.1.5.1.
 2) SUBMIT MANUFACTURER'S SPECIFICATION SHEETS FOR THE
 MAIN DRAINS. WPB AMEND. TO FBC SEC. 107.2.1.
 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE PUMPS
 INCLUDING THE PUMP CURVE. WPB AMEND. TO FBC SEC.
 107.2.1.
 4) SUBMIT SPECIFICATIONS FOR THE CHLORINE FEEDER, PH
 FEEDER, & SALT CHLORINATOR. WPB AMEND. TO FBC SEC.
 107.2.1.
 5) THE PLANS REFER TO A POOL HEATER. SUBMIT
 MANUFACTURER'S SPECIFICATIONS FOR THE POOL HEATER. THE
 HEATER SHALL COMPLY WITH 2014 FBC-ENERGY SEC. C404.7.
 6) SHT. 3 CALLS OUT 6 INCH MAIN DRAINS BUT SHT. 4 SHOWS
 ONE OF THE MAIN DRAINS AS 4 INCH. CLARIFY.
 7) SHOW COMPLIANCE WITH 2014 FBC SEC.454.1.6.5.7.
 PROPORTIONING VALVES ARE REQUIRED ON RETURN, MAIN DRAIN
 AND SURFACE OVERFLOW LINES.
 8) SHT. 3 OF 7 LISTS THE WIDTH OF THE POOL AS 26 FEET,
 8 INCHES BUT SHT. 2 OF 7 HAS A MEASUREMENT OF 35 FEET,
 8 INCHES. I COULD NOT FIND THE 26 FEET, 8 INCH
 DIMENSION ON THE PLAN. CLARIFY
 REVIEW NOT COMPLETE.
 9) IF THE POOL IS GREATER THAN 30 FEET WIDE, THE POOL
 SHALL HAVE EITHER FLOOR INLETS ONLY OR A COMBINATION OF
 FLOOR AND WALL INLETS PER 2014 FBC SEC.454.1.6.5.9.4.
 10) IF A POOL HEATER IS BEING INSTALLED, A TIME SWITCH
 OR OTHER METHOD THAT CAN AUTOMATICALLY TURN OFF AND ON
 HEATERS COMPLYING WITH 2014 FBC-ENERGY SEC.C404.7.2
 SHALL BE INSTALLED.
 11) HEATED SWIMMING POOLS SHALL BE EQUIPPED WITH COVERS
 COMPLYING WITH 2014 FBC-ENERGY SEC.C404.7.3.
 12) THE FILTRATION SYSTEM FOR SWIMMING POOLS SHALL BE
 CAPABLE OF MEETING ALL OTHER REQUIREMENTS OF THESE
 RULES WHILE PROVIDING A FLOW RATE OF AT LEAST 0.75 GPM
 FOR EACH LIVING UNIT AT NONTRANSIENT UNIT. CONFIRM
 COMPLIANCE. 2014 FBC SEC.454.1.1.1.
 13) THE POOL WATER SHALL NOT DRAIN TO THE SANITARY OR
 STORM DRAINAGE SYSTEM PER CITY ORDINANCE SEC. 90-126 (
 B ) ( 5 ) & 90-203, 90-205.
 14) POOLS EQUIPPED WITH HEATERS SHALL HAVE A FIXED
 THERMOMETER MOUNTED IN THE POOL RECIRCULATION LINE
 DOWNSTREAM FROM THE HEATER OUTLET PER 2014 FBC
 SEC.454.1.6.5.14.
 15) PIPING AND INFLUENT, EFFLUENT AND BYPASS VALVES
 WHICH ALLOW ISOLATION OR REMOVAL OF THE HEATER FRROM
 THE SYSTEM SHALL BE PROVIDED. 2014 FBC
 SEC.454.1.6.5.14.
 16) ALL CHEMICALS SHALL BE FED INTO THE RETURN LINE
 AFTER THE PUMP, HEATER AND FILTERS IN ACCORDANCE WITH
 2014 FBC SEC.454.1.6.5.16.
 17) A ROOM OR SPACE SHALL BE PROVIDED FOR CHEMICALS TO
 BE STORED IN ACCORDANCE WITH 2014 FBC SEC. 454.1.3.3.4.
 18) VAK PAK SHEET ( 5 OF 7) REFERS TO AP 16C. WHAT IS
 THIS? I COULD NOT FIND ANY INFORMATION ON THIS ON THE
 VAK PAK WEBSITE. CLARIFY/SUBMIT SPECIFICATIONS.
 19) THE AUTOFILL FOR THE COLLECTOR TANK SHALL BE
 EQUIPPED WITH A BACKFLOW PREVENTION DEVICE. 2014 FBC
 SEC. 454.1.6.3.
 20) SHT. 3 OF 7 SHOWS THE BATHING LOAD AS 23 PERSONS
 AND SHT. A-1.00 SHOWS THE POOL OCCUPANT LOAD AS 35.
 CLARIFY.ALSO THE AREA OF THE POOL IS SHOWN AS 1737 SQ.
 FT. ON A-1.00 AND SHT.3 OF 7 SHOWS 1397 SQ. FT.
 CLARIFY.
 21) INDICATE THE TERMINATION POINT OF THE FLOOR DRAIN
 IN THE VAK PAK ENCLOSURE. A TRAP PRIMER WILL BE
 REQUIRED IF CONNECTED TO THE SANITARY SYSTEM.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop Z ZONING
Rev No 4 Status P Date 2016-09-20 Cont ID  
Sent By njwira Date 2016-09-20 Time 14:25 Rev Time 0.00
Received By njwira Date 2016-09-20 Time 14:25 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2016-09-15 Cont ID  
Sent By njwira Date 2016-09-15 Time 16:39 Rev Time 0.00
Received By njwira Date 2016-09-13 Time 14:22 Sent To P
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2016-08-29 Cont ID  
Sent By njwira Date 2016-08-29 Time 16:06 Rev Time 0.00
Received By njwira Date 2016-08-24 Time 13:46 Sent To P
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2016-07-07 Cont ID  
Sent By jwitmer Date 2016-08-05 Time 10:54 Rev Time 0.00
Received By njwira Date 2016-07-07 Time 15:26 Sent To  
Notes
2016-07-08 09:27:21POOL BOX
2016-07-07 15:27:407/7/16- FAILED
  
 1. NEED A COPY OF A SURVEY SHOWING WHERE THE POOL AND
 POOL EQUIPMENT IS LOCATED IN RELATION TO THE SETBACK
 REQUIREMENTS.
  
 PLEASE CONTACT:
 NATHAN WIRA
 (561)822-1442
 [email protected]
  