Plan Review Details - Permit 16070093
Plan Review Stops For Permit 16070093
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-09-09 Cont ID  
Sent By cthroop Date 2016-09-09 Time 09:15 Rev Time 0.00
Received By cthroop Date 2016-09-09 Time 09:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-07-14 Cont ID  
Sent By mvaldes Date 2016-07-14 Time 19:38 Rev Time 0.00
Received By cthroop Date 2016-07-14 Time 08:24 Sent To Z
Notes
2016-07-14 08:29:22BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 ACTION: DENIED
 DATE: 7/14/16
  
 1. COMPONENTS AND CLADDING MATERIALS SUBJECT TO WIND
 LOADS SHALL COMPLY WITH CHPT. 16 FBC AND ASCE 7-10.
 PROVIDE WIND DESIGN LOADS FOR PROPOSED SIGN.
 2. LIST GOVERNING CODES (2014 FBC 5TH ED.) ON PLANS.
  
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
 2. RISK CATEGORY.
 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-09-08 Cont ID  
Sent By mvaldes Date 2016-09-08 Time 10:23 Rev Time 0.00
Received By mvaldes Date 2016-09-08 Time 10:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-07-13 Cont ID  
Sent By mvaldes Date 2016-07-13 Time 19:38 Rev Time 0.00
Received By mvaldes Date 2016-07-13 Time 19:29 Sent To B
Notes
2016-07-13 19:36:14REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
  
 - NEC 600.5 SIGN SHALL BE ON A DEDICATED 20 AMP BRANCH
 CIRCUIT IF EXISTING MARK ON PLANS.
  
 - NEC 600.6 PROVIDE A DISCONNECT WITHIN SIGHT OF THE
 SIGN. THIS APPLIES FOR BOTH NORTH AND SOUTH SIDE !
  
 - ALL GROUNDING AND BONDING SHALL BE IN ACCORDANCE WITH
 NEC 600.7. ( GENERAL COMMENT )
  
 - C405.2.4 EXTERIOR LIGHTING CONTROLS. LIGHTING NOT
 DESIGNATED FOR DUSK-TO-DAWN OPERATION SHALL BE
 CONTROLLED BY EITHER A COMBINATION OF A PHOTOSENSOR AND
 A TIME SWITCH, OR AN ASTRONOMICAL TIME SWITCH. LIGHTING
 DESIGNATED FOR DUSK-TO-DAWN OPERATION SHALL BE
 CONTROLLED BY AN ASTRONOMICAL TIME SWITCH OR
 PHOTOSENSOR.
 ALL TIME SWITCHES SHALL BE CAPABLE OF RETAINING
 PROGRAMMING AND THE TIME SETTING DURING LOSS OF POWER
 FOR A PERIOD OF AT LEAST 10 HOURS.
2016-07-13 10:53:13SENT TO ZONING FOR REVIEW

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-09-09 Cont ID  
Sent By cthroop Date 2016-09-09 Time 09:10 Rev Time 0.00
Received By cthroop Date 2016-08-19 Time 09:45 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-07-25 Cont ID  
Sent By eschneid Date 2016-07-25 Time 15:32 Rev Time 0.00
Received By eschneid Date 2016-07-05 Time 08:44 Sent To  
Notes
2016-07-06 08:44:38ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2016-09-02 Cont ID  
Sent By cthroop Date 2016-09-09 Time 09:10 Rev Time 0.25
Received By eschneid Date 2016-09-02 Time 08:53 Sent To E
Notes
2016-09-02 09:13:08NORTH SIGN
  
 SUITE #1 AND #2 SF COMBINED BY APPOVED MINOR AMENDMENT
 PB1399P
  
 PERMITTED SIGN: 46 SF
 PROPOSED SIGN: 46 SF
  
 SOUTH SIGN
  
 SUITE #1 AND #2 SF COMBINED BY APPOVED MINOR AMENDMENT
 PB1399P
  
 PERMITTED SIGN: 56 SF
 PROPOSED SIGN: 46 SF
  

Review Stop Z ZONING
Rev No 1 Status F Date 2016-07-25 Cont ID  
Sent By eschneid Date 2016-07-25 Time 13:18 Rev Time 0.50
Received By eschneid Date 2016-07-25 Time 13:18 Sent To  
Notes
2016-07-25 15:29:06FAILED
  
 NORTH SIGN
  
 1) THE SIGN BOX SHALL INCLUDE ALL OF THE FEATURES OF
 THE SIGN. THE PROVIDED PLAN FAILS TO INCLUDE THE TOP OF
 THE FLAME IN THE BOX. THE DIMENSION SHALL BE PROVIDED
 FOR THE HEIGHT OF THE FLAME.
  
 2) THE DIMENSION FOR THE AREA BETWEEN THE WORD "PIZZA"
 AND THE "U BUILD IT WE FIRE IT" SHALL BE INCLUDED SO
 THAT STAFF CAN VERIFY THE OVERALL SIGN SQUARE FOOTAGE.
  
 PERMITTED SIGN: 46 SF
 PROPOSED SIGN: UNKNOWN
  
 SOUTH SIGN
  
 1) THE SIGN BOX SHALL INCLUDE ALL OF THE FEATURES OF
 THE SIGN. THE PROVIDED PLAN FAILS TO INCLUDE THE TOP OF
 THE FLAME IN THE BOX. THE DIMENSION SHALL BE PROVIDED
 FOR THE HEIGHT OF THE FLAME.
  
 2) THE DIMENSION FOR THE AREA BETWEEN THE WORD "PIZZA"
 AND THE "U BUILD IT WE FIRE IT" SHALL BE INCLUDED SO
 THAT STAFF CAN VERIFY THE OVERALL SIGN SQUARE FOOTAGE.
  
 PERMITTED SIGN: 56 SF
 PROPOSED SIGN: UNKNOWN
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
  
2016-07-14 11:15:06ROUTED TO ERIC SCHNEIDER


Account Summary | Usage Policy | Privacy Policy