| 2016-07-05 12:06:29 | BUILDING PLAN REVIEW |
| | 2014 FLORIDA BUILDING CODE |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | BUILDING PLANS EXAMINER ? PX3169 |
| | CONSTRUCTION SERVICES DIVISION |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | DATE: 7/5/16 |
| | |
| | 1. REPAIR TO ROOF JOIST MAY REQUIRE A ROOFING PERMIT. |
| | IF ROOFING IS REPAIRED, PROVIDE PRODUCT APPROVALS FOR |
| | ROOF SYSTEM. |
| | 2. PLAN IS NOT CLEAR WHAT IS EXISTING AND WHAT WILL BE |
| | REPLACED. ARE ALL ELEMENTS OF TYP. WALL SECTION TO BE |
| | REPLACED? CONCRETE SLAB? (MISSING RE-INFORCING) 2X4 |
| | BOTTOM PLATE? SPACING OF 1/2" X 5" ANCH. BOLTS? PRODUCT |
| | TO BE USED FOR SUB-FLOORING? ROOF SHEATHING? WIND LOAD |
| | ENGINEERING AND FASTENER SCHEDULE. |
| | 3. WALL SECTION SHOWS 2X4 BOTTOM PLATE, 2X4 TOP PLATE |
| | AND 2X6 WALL STUDS. PLEASE CLARIFY. |
| | 4. PROVIDE FLOOR PLAN INDICATING THE LOCATION OF |
| | REPAIRS IN STRUCTURE. |
| | 5, PROVIDE SPAN OF NEW 2X6 FLOOR JOISTS. |
| | 6. PROVIDE DETAIL FOR EXTERIOR WALL SYSTEM. |
| | 7. CANNOT DETERMINE IF VALUE IS ADEQUATE. NEED |
| | ADDITIONAL INFORMATION. |
| | 8. PROVIDE SCOPE OF WORK CLEARLY IDENTIFYING WORK TO BE |
| | PERFORMED. |
| | 9. PROTECTION OF WOOD FLOOR JOIST PER R317.1 IF CRAWL |
| | SPACE IS LESS THAN 18". |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY |
| | REVIEWED SHEETS DETACHED. |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | CONSTRUCTION DOCUMENTS SHALL BE |
| | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. |
| | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY |
| | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK |
| | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE |
| | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, |
| | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING |
| | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL |
| | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, |
| | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS |
| | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH |
| | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES |
| | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE |
| | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE |
| | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, |
| | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE |
| | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE |
| | DESIGN. (SEE ALSO SECTION 107.3.5). |
| | |
| | |