|
 |
 |
 |
 |
 |
Plan Review Details - Permit 16061600
| Plan Review Stops For Permit 16061600 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-08-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-08-05 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-08-05 |
Time |
13:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-07-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-07-01 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-07-01 |
Time |
15:10 |
Sent To |
HIST |
|
| Notes |
| 2016-07-01 15:11:50 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER ? PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | DATE: 7/1/16 | | | | | | 1. PROVIDE WIND LOADS FOR OPENINGS. | | | | | | 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | 2. RISK CATEGORY. | | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. | | | 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | | M2). | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-07-08 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2016-07-08 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2016-07-08 |
Time |
15:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-08-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-08-05 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-08-03 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2016-08-03 16:17:06 | RESUB ROUTED TO CTHROOP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-07-08 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-07-08 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-06-29 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2016-06-29 13:49:16 | BLDG -$5000 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |