Plan Review Details - Permit 16061408
| Plan Review Stops For Permit 16061408 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-07-08 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-07-08 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-07-08 |
Time |
11:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-06-28 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2016-06-28 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2016-06-28 |
Time |
17:08 |
Sent To |
|
|
| Notes |
| 2016-06-28 17:18:37 | ****CORRECTIONS**** | | | | | | ART LANGE - BUILDING INSPECTOR | | | 561-805-6667 [email protected] | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION/ FRC FLORIDA | | | RESIDENTIAL CODE 2015 5TH EDITION | | | | | | | | | | | | | | | 1. DESIGN PROFESSIONAL | | | FBC-107.1 GENERAL - FAC 61G1-16.004 - A TITLE BLOCK | | | MUST APPEAR ON ALL ARCHITECTURAL OR INTERIOR DESIGN | | | DRAWINGS AND SPECIFICATION IDENTIFICATION SHEETS THAT | | | ARE REQUIRED TO BE SIGNED AND SEALED. THE TITLE BLOCK | | | MUST, AT A MINIMUM, CONTAIN THE FOLLOWING INFORMATION: | | | (1) FIRM NAME, ADDRESS, AND TELEPHONE NUMBER. | | | (2) FIRM LICENSE NUMBER. | | | (3) NAME OR IDENTIFICATION OF PROJECT. | | | (4) DATE PREPARED. | | | (5) A SPACE FOR THE SIGNATURE AND DATED SEAL. | | | (6) THE PRINTED NAME AND THE LICENSE/REGISTRATION | | | NUMBER OF THE PERSON SEALING THE DOCUMENT. | | | (7) THE DATE OF PLANS REVISION, IF THE PLANS ARE | | | REVISED. | | | (8) FOR THE PURPOSES OF THIS RULE, FIRM IS DEFINED TO | | | BE A CORPORATION, LIMITED LIABILITY COMPANY, | | | PARTNERSHIP, PERSON PRACTICING UNDER A FICTITIOUS NAME, | | | OR PERSON PRACTICING ARCHITECTURE OR INTERIOR DESIGN IN | | | HIS OR HER OWN NAME. | | | | | | 2. PROVIDE DESIGN CRITERIA ON PLANS FBC 3105.3, FBC | | | 3105.4 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-06-28 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2016-06-28 |
Time |
17:18 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2016-06-24 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2016-06-27 09:38:33 | ROUTED TO ZONING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2016-07-08 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2016-07-07 |
Time |
13:22 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2016-06-29 |
Time |
15:48 |
Sent To |
B |
|
| Notes |
| 2016-07-08 09:10:53 | AWNINGS COMPLY WITH APPROVED TOO JAY'S MINOR PD | | | AMENDMENT. | | | | | | THE SIGNAGE ON THE AWNINGS REQUIRES A SEPARATE PERMIT | | | WITH PLANS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2016-06-28 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2016-06-28 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-06-28 |
Time |
16:03 |
Sent To |
B |
|
| Notes |
| 2016-06-28 16:07:21 | 6/28/16- FAILED | | | | | | ZONE: PALM BEACH OUTLET MALL PLANNED DEVELOPMENT. | | | | | | 1. AWNING CANNOT EXCEED 4FT. ON A VARIENCE THIS AWNING | | | IS 11FT. 4 AND 7/8IN. EXCEEDING THE MAXIMUM LIMIT OF AN | | | AWNING. | | | 2. CANOPY IS 3FT. 6IN. MEETS THE 4FT. MAXIMUM LIMIT ON | | | A CANOPY. | | | 3. WALL SIGN IS IN THE CORRECT LOCATION. | | | | | | PLEASE CONTACT: | | | NATHAN WIRA | | | (561)822-1442 | | | [email protected] | | | |
|
|
|