| 2016-08-10 18:58:20 | NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW |
| | COMMENTS. |
| | CODE: FBC 5TH EDITION (2014) |
| | |
| | 1- AFTER PLANS ARE REVISED, PLEASE BRING THEM TO PALM |
| | BEACH COUNTY (2300 N. JOG RD) FOR IMPACT FEES |
| | ASSESSMENT. COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED |
| | LAND DEVELOPMENT CODE. (NOTE: THIS MAY BE DONE WHEN |
| | PERMIT IS READY TO BE ISSUED). |
| | |
| | 2- PROVIDE SOIL TEST REPORT (2 COPIES) AS REQUIRED BY |
| | SEC. R401.4 FBC-RESIDENTIAL, 5TH EDITION (2014). |
| | |
| | 3- ENERGY CALCULATIONS SUBMITTED: |
| | A) OWNER/AGENT TO CERTIFY BOTTOM OF FORM AS REQUIRED BY |
| | SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION |
| | (2014). |
| | |
| | B) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, |
| | INCLUDING OWNER NAME, BUILDER NAME, PERMIT OFFICE AND |
| | JURISDICTION NUMBER. SEC. R101.5.1.1.2 FBC-ENERGY |
| | CONSERVATION. |
| | |
| | C) CONDITIONED AREA SHOWN ON ITEM #6 DOESN'T MATCH |
| | CONDITIONED AREA SHOWN ON PLANS (EVEN INCLUDING THE |
| | GARAGE). INFORMATION ON PLANS AND ENERGY CALCULATIONS |
| | NEED TO BE COORDINATED. SEC. R103.2 FBC-ENERGY |
| | CONSERVATION. REVISE AS REQUIRED. |
| | |
| | D) ITEM #10 CALLS FOR VENTED ATTIC. ARCHITECTURAL PLANS |
| | DON'T SPECIFY VENTED ATTIC. INFORMATION ON PLANS AND |
| | ENERGY CALCULATIONS NEED TO BE COORDINATED. SEC. R103.2 |
| | FBC-ENERGY CONSERVATION. REVISE AS REQUIRED. |
| | |
| | E) FIRST FLOOR CEILING IS NOT WOOD TRUSSES AND |
| | ARCHITECTURAL PLANS DON'T SPECIFY INSULATION BETWEEN |
| | 1ST AND 2ND FLOOR. SEE PLANS AND SECTIONS. INFORMATION |
| | ON PLANS AND ENERGY CALCULATIONS NEED TO BE |
| | COORDINATED. SEC. R103.2 FBC-ENERGY CONSERVATION. |
| | REVISE CEILING INFORMATION ON PAGE 3 OF 6 AS REQUIRED. |
| | |
| | F) BUILDER TO COMPLETE THE EPL DISPLAY CARD AS REQUIRED |
| | BY SEC. R405.3 FBC-ENERGY CONSERVATION. |
| | |
| | G) COMPLETE THE INSPECTION CHECKLIST (TABLE 402.4.1.1 |
| | SUBMITTED) AS REQUIRED BY SEC. R405.4.2 FBC-ENERGY |
| | CONSERVATION. |
| | |
| | NOTE: LABEL FOR WINDOWS AND DOORS SHOWING THE U-FACTOR |
| | AND SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS |
| | WILL BE REQUIRED WHEN ENERGY CALCULATIONS ARE NOT USING |
| | THE SOFTWARE DEFAULT FACTOR FOR GLAZING. |
| | |
| | 4- PROPERTY IS LOCATED IN FLOOD ZONE A5. ELEVATION |
| | CERTIFICATES WILLL BE REQUIRED DURING CONSTRUCTION. |
| | CITY CODE SEC. 94-546 REQUIRES MIN. FINISHED FLOOR |
| | ELEVATION OF 7'-6". PLANS TO SPECIFY THE PROPOSED |
| | FINISHED FLOOR ELEVATION, INCLUDING LOWEST POINT OF THE |
| | GARAGE AND ELEVATION OF ALL EQUIPMENT.. CONSTRUCTION IN |
| | FLOOD ZONES NEED TO COMPLY WITH THE FLOOD RESISTANT |
| | CONSTRUCTION SEC. R322 OF FBC-RESIDENTIAL. N OTE: IF |
| | THE GARAGE FINISHED FLOOR (AT THE LOWEST POINT) IS LESS |
| | THAN 7'-6", THEN FLOOD VENTS WILL BE REQUIRED. SEE SEC. |
| | R322.2.2 FOR SPECIFICATIONS AND LOCATION. |
| | |
| | NOTE: PLEASE COORDINATE ELEVATION CERTIFICATES WITH |
| | SAMANTHA HILL TO AVOID DELAYS OR CONFLICTS AT |
| | (561)805-6712 OR [email protected] |
| | |
| | 5- COVER DRAWING: |
| | A) GENERAL NOTE #10 IS REFERENCING FBC 2007 WITH 2009 |
| | AMENDMENTS. THE CURRENT CODE IS THE FBC 5TH EDITION |
| | (2014). |
| | |
| | B) NOTE#10 STATES THAT ALL DESIGN LOADS NOT INDICATED |
| | ON DRAWINGS SHALL BE GOVERNED BY THE APPLICABLE |
| | BUILDING CODE. ALL DESIGN LOADS NEED TO BE SPECIFIC AND |
| | INDICATED ON THE CONSTRUCTION DRAWINGS WITHOUT CITING |
| | THE CODE AS A WHOLE OR IN PART. SEC. 107.2.1 CITY |
| | AMENDMENTS. REVISE AS REQUIRED. |
| | |
| | C) ENERGY CODE SECTION REFERENCED ON GENERAL NOTE #7 |
| | NEEDS TO BE UPDATED TO CURRENT CODE. SEE RESIDENTIAL |
| | SECTION OF FBC-ENERGY CONSERVATION, 5TH EDITION (2014) |
| | AND PROVIDE CORRECT SECTION. |
| | |
| | D) REVISE THE INDEX OF DRAWINGS. THERE IS NO SHEET |
| | A103. SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 6-SHEET A000: |
| | A) REVISE CONSTRUCTION TYPE. SEE TABLE 601 AND SEC. |
| | 602.5 OF FBC-BUILDING, 5TH EDITION (2014) FOR CORRECT |
| | TYPE OF CONSTRUCTION. |
| | |
| | B) REVISE OCCUPANCY GROUP AND RESIDENTIAL SECTION |
| | REFERENCED. SEE SEC. 310.5 OF FBC-BUILDING, 5TH EDITION |
| | (2014) AND EXCEPTION #1 OF SEC. 101.2 CITY AMENDMENTS. |
| | |
| | 7- SHEET A100: |
| | A) SPECIFY SELF CLOSING DEVICE FOR GARAGE DOOR LEADING |
| | FROM GARAGE TO MUD ROOM AREA (DOOR #121) AS REQUIRED BY |
| | SEC. R302.5.1 FBC-RESIDENTIAL. |
| | |
| | B) GUEST BATHROOM DOOR ON FIRST FLOOR NEEDS TO COMPLY |
| | WITH THE 29" MIN. CLEAR OPENING AS REQUIRED BY SEC. |
| | R320 FBC-RESIDENTIAL. REVISE SIZE OF DOOR AS REQUIRED. |
| | |
| | 8- SHEET A101: |
| | A) SIZE OF EGRESS WINDOWS FOR BEDROOMS #2, #3 AND #4 IS |
| | NOT CLEAR. THE WINDOW FRAME SIZE SPECIFIED ON THE |
| | WINDOW SCHEDULE ON SHEET A550 IS NOT LISTED ON THE |
| | SINGLE HUNG WINDOW PRODUCT APPROVAL SUBMITTED (NOA |
| | 15-0129.03). IF THIS IS A CUSTOM SIZED WINDOW, THEN |
| | PROVIDE MANUFACTURER'S CUT SHEETS SHOWING THAT THE |
| | SPECIFIED SIZE OF WINDOW COMPLY WITH ALL THE OPENING |
| | DIMENSIONS REQUIRED BY SEC. R310 FBC-RESIDENTIAL. ON |
| | THE OTHER HAND, DIMENSIONS SHOWN ON THE EGRESS WINDOW |
| | DRAWING ON SHEET A550 DON'T MATCH DIMENSIONS SHOWN ON |
| | THE WINDOW SCHEDULE AND WINDOW TYPE "C" DETAIL SHOWN ON |
| | THE SAME DRAWING. REVISE AS REQUIRED SO EGRESS |
| | REQUIREMENTS CAN BE VERIFIED. |
| | |
| | B) ATTIC ACCESS LOCATED IN THE MECHANICAL ROOM DOESN'T |
| | COMPLY WITH SEC. R807 FBC-RESIDENTIAL. ATTIC ACCESS |
| | SHALL BE LOCATED IN A HALLWAY OR OTHER READILY |
| | ACCESSIBLE LOCATION. THE MECHANICAL EQUIPMENT WIL BLOCK |
| | THE DIRECT ACCESS. REVISE AS REQUIRED. |
| | |
| | 9- ROOF PLANS DON'T SHOW ANY CRICKETS WHERE THE ROOF |
| | MEETS WALL BY THE GUEST SUITE WING. PROVIDE COMPLETE |
| | DETAILS AND SPECIFICATIONS SHOWING HOW DIVERTING WATER. |
| | SEC. R903.2.2 FBC-RESIDENTIAL. SEC. 107.2.1 CITY |
| | AMENDMENTS |
| | |
| | 10- PROVIDE DETAIL/SPECIFICATIONS FOR THE CEILING |
| | CONSTRUCTION ABOVE GARAGE SHOWING COMPLIANCE WITH TABLE |
| | R302.6 FBC-RESIDENTIAL. |
| | |
| | 11- ACCORDING TO SIZE OF WINDOWS SHOWN ON THE WINDOW |
| | SCHEDULE, WINDOW TYPES AND WINDOW SILL DETAIL SHOWN ON |
| | SHEET A550 IT LOOKS LIKE THE SECOND FLOOR WINDOWS NEED |
| | TO COMPLY WITH THE WINDOW FALL PROTECTION SEC. R312.2 |
| | FBC-RESIDENTIAL. PROVIDE COMPLETE DETAILS AND |
| | SPECIFICATIONS SHOWING COMPLIANCE. |
| | |
| | 12- SHEET A302: |
| | A) THERE ARE TWO DIFFERENT SPECIFICATIONS FOR THE SLOPE |
| | OF THE TERRACE DECK. THE REQUIRED SLOPE IS 1/4 PER |
| | FOOT. FOR DRAINAGE. SEC. R905.11.1 FBC-RESIDENTIAL. |
| | REVISE AS REQUIRED. SAME APPLIES TO SHEET A303. |
| | |
| | B) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE |
| | CONSTRUCTION OF THE TERRACE GUARDRAILS SHOWING |
| | COMPLIANCE WITH THE LIVE LOADS OF TABLE R301.5 AND SEC. |
| | R312.1 FBC-RESIDENTIAL. WROUGHT ALUMINUM NOTES ARE JUST |
| | CITING CODE SECTIONS. CODE SECTIONS CITED ARE |
| | INCORRECT. CITING THE CODE AS A WHOLE OR IN PART IS NOT |
| | ALLOWED (SEC. 107.2.1 CITY AMENDMENTS). REVISE AS |
| | REQUIRED AND PROVIDE COMPLETE DESIGN INFORMATION. NOTE: |
| | SHOP DRAWINGS WILL BE REQUIRED PRIOR TO |
| | FABRICATION/INSTALLATION TO AVOID CONFLICTS/DELAYS. |
| | SAME APPLIES TO SHEET A303. |
| | |
| | C) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE |
| | LOGGIA CEILING CONSTRUCTION. SEC. R301.1 |
| | FBC-RESIDENTIAL. |
| | |
| | 13- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE |
| | CONSTRUCTION OF THE STAIRWAY SHOWING COMPLIANCE WITH |
| | SEC. R311.7 FBC-RESIDENTIAL. SPECIFY RISERS AND TREADS. |
| | |
| | 14- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE |
| | CONSTRUCTION OF THE HANDRAILS AND INTERIOR GUARDRAILS |
| | SHOWING COMPLIANCE WITH TABLE R301.5 , SEC. R311.7.8 |
| | AND SEC. R312.1 FBC-RESIDENTIAL. |
| | |
| | 15- ALL STRUCTURAL PLANS TO HAVE ENGINEER'S ORIGINAL |
| | SEAL AND SIGNATURE (NO COPIES) AS REQUIRED BY CHAPTER |
| | 471 FLORIDA STATUTES. |
| | |
| | 16- SHEET S8: |
| | A) ACCORDING TO SEC. R301.2.1.4 FBC-RESIDENTIAL THIS |
| | BUILDING IS LOCATED IN EXPOSURE "D" NOT "C". REVISE THE |
| | WIND LOADING NOTES AS REQUIRED. |
| | |
| | B) REVISE THE COMPONENTS AND CLADDING DESIGN WIND |
| | PRESSURES TO CORRESPOND TO EXPOSURE "D" AS REQUIRED BY |
| | ITEM #16(A) ABOVE. NOTE: REVISE THE DOORS AND WINDOWS |
| | DESIGN PRESSURES SHOWN ON PLANS AND THE ROOF DESIGN |
| | PRESSURES SHOWN ON SHEET S6. |
| | (NOTE: PRODUCT APPROVALS WILL BE REVIEWED ONCE THE |
| | DESIGN PRESSURES ARE REVISED). |
| | |
| | C) CLARIFY WHY THE DESIGN PRESSURES SHOWN ON THE |
| | COMPONENTS AND CLADDING DESIGN WIND PRESSURES ARE LOWER |
| | WHEN THE WALL IS HIGHER. SEC. R301.1 FBC-RESIDENTIAL. |
| | |
| | 17- PROVIDE ICC EVALUATION REPORT. FOR THE ICYNENE FOAM |
| | INSULATION SPECIFIED ON PLANS SHOWING COMPLIANCE WITH |
| | SEC. R316 FBC-RESIDENTIAL. |
| | |
| | 18- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | FAC 61G20-3.002(33) FOR: |
| | A) METAL ROOFING AS SPECIFIED ON PLANS. PRODUCT |
| | APPROVAL FL7804-R8 SUBMITTED IS FOR CONCRETE TILES. |
| | |
| | B) WINDOW MULLIONS AS SHOWN ON PLANS. AND, SPECIFY |
| | MULLION SIZE TO VERIFY COMPLIANCE WITH THE CALCULATED |
| | DESIGN PRESSURES. |
| | |
| | C) HARDI PLANK SIDING AS SPECIFIED ON PLANS. |
| | |
| | D) INSWING FRENCH DOORS AS SHOWN ON PLANS FOR THE LOFT |
| | AREA. |
| | |
| | E) PRECAST LINTELS AS SPECIFIED ON PLANS. |
| | |
| | F) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON |
| | FRAMING PLANS AND ALL DETAILS. PROVIDE FLORIDA PRODUCT |
| | APPROVAL COVER PAGE AND PAGE SHOWING THE SPECIFIED |
| | CONNECTOR OR LIST THE FLORIDA PRODUCT APPROVAL NUMBER |
| | NEXT TO EACH SPECIFIED CONNECTOR. NOTE: REVISE THE |
| | FLORIDA PRODUCT APPROVAL NUMBER LISTED ON THE TRUSS |
| | CONNECTOR ON SHEET S3. FLORIDA PRODUCT APPROVALS |
| | FL3750.77 AND FL 3750.81 ARE NOT LISTED ON THE FLORIDA |
| | PRODUCT APPROVAL WEBSITE. REVISE AS REQUIRED. |
| | |
| | G) ENTRY DOOR WITH SIDELITES AS SHOWN ON PLANS. |
| | |
| | H) DOUBLE FRENCH DOORS WITH SIDELITES AS SHOWN ON |
| | PLANS. |
| | |
| | I) LAUNDRY EXTERIOR DOOR AS SHOWN ON PLANS AND DOOR |
| | SCHEDULE. |
| | |
| | J) SINGLE OUTSWING DOORS AS SHOWN ON PLANS AND DOOR |
| | SCHEDULE FOR HIS CLOSET AND STAIR HALL ON THE SECOND |
| | FLOOR. NOTE: ANDERSEN CORPORATION DOORS DWG AWD024 |
| | SUBMITTED DON'T HAVE A FLORIDA PRODUCT APPROVAL NUMBER |
| | OR MIAMI-DADE NOA NUMBER. . IF THERE IS NOT A FLORIDA |
| | PRODUCT APPROVAL OR MIAMI-DADE NOA, THEN MANUFACTURER |
| | MAY APPLY FOR LOCAL PRODUCT APPROVAL. COMPLETE ORIGINAL |
| | ENGINEER PACKAGE WILL BE REQUIRED FOR BUILDING OFFICIAL |
| | REVIEW AND APPROVAL. ADVISE IF APPLYING FOR LOCAL |
| | PRODUCT APPROVAL SO I CAN PROVIDE MORE INFORMATION |
| | ABOUT THE PROCEDURE. |
| | |
| | K) ROUND WINDOWS AS SPECIFIED ON PLANS. |
| | |
| | L) CLARIFY WHY SUBMITTING PRODUCT APPROVALS FOR SLIDING |
| | GLASS DOORS AND CASEMENT WINDOWS. . THERE ARE NOT |
| | CASEMENT WINDOWS OR SLIDING GLASS DOORS SPECIFIED ON |
| | PLANS. |
| | |
| | M) HURRICANE SHUTTERS AS SHOWN ON PLANS AND PROVIDE |
| | COMPLETE INSTALLATION SCHEDULE. SEE CITY SAMPLE OF |
| | INSTALLATION SCHEDULE OR PROVIDE ANY OTHER FORMAT THAT |
| | CONTAINS ALL THE REQUIRED INFORMATION. |
| | |
| | N) WATERPROOFING UNDERLAYMENT USED FOR THE MASTER AND |
| | POOL TERRACES. NEED PRODUCT THAT IS DESIGNED TO RECEIVE |
| | CAST STONE FLOORING AS SPECIFIED ON PLANS. NOTE: |
| | CLEARLY IDENTIFY WHICH APPROVED ASSEMBLY FROM THE |
| | SUBMITTED PRODUCT APPROVAL IS GOING TO BE USED TO |
| | VERIFY COMPLIANCE WITH THE CALCULATED DESIGN PRESSURES. |
| | |
| | 19- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL THE PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| | |
| | IMPORTANT: |
| | (1) ELEVATION CERTIFICATES WILL BE REQUIRED DURING |
| | CONSTRUCTION. NOTE: COORDINATE ALL ELEVATION |
| | CERTIFICATES WITH SAMANTHA HILL AT [email protected] OR |
| | (561)805-6724 TO AVOID CONFLICTS OR DELAYS. |
| | (2) SUBMIT SHOP DRAWINGS FOR THE DESIGNED FLOOR SYSTEM. |
| | PACKAGE TO BE APPROVED BY THE DESIGNER OF RECORD PRIOR |
| | TO SUBMITTAL TO THIS OFFICE. |
| | |
| | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO EXPEDITE THE REVIEW PROCESS. |
| | ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| | DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS |
| | FOR REFERENCE |
| | |