Plan Review Details - Permit 16061279
Plan Review Stops For Permit 16061279
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-09-01 Cont ID  
Sent By   Date 2016-09-01 Time 07:59 Rev Time 0.00
Received By jwitmer Date 2016-09-01 Time 07:12 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-07-06 Cont ID  
Sent By jwitmer Date 2016-07-06 Time 10:28 Rev Time  
Received By jwitmer Date 2016-07-06 Time 09:00 Sent To  
Notes
2016-07-06 10:35:21BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16061279
 ADD: 4375 EASLEY DR.
 CONT: TBD/ TO BE DETERMINED
 TEL: ???????????????? NO CONTACT INFO.
 E-MAIL: ?????????????? NO CONTACT INSO.
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. JULY 06/2016
 ACTION: DENIED
  
 1) SHEET S1.3 SHOWS A HAND RAIL WITH MULTIPLE STEPS AND
 WHAT APPEARS THE GRADE GREATER THAN 30 INCHES WITH NO
 GUARD RAIL. PLEASE PROVIDE A SECTION THROUGH THE PLANS
 WHERE THIS HANDRAIL IS TO BE INSTALLED AND WHY THERE IS
 NOT A GUARDRAIL INCOMPLIANCE WITH THE 2014 FBC-B
 SECTION 1013.2 WHERE REQUIRED.
 GUARDS SHALL BE LOCATED ALONG OPEN-SIDED WALKING
 SURFACES, INCLUDING MEZZANINES, EQUIPMENT PLATFORMS,
 STAIRS, RAMPS AND LANDINGS THAT ARE LOCATED MORE THAN
 30 INCHES (762 MM) MEASURED VERTICALLY TO THE FLOOR OR
 GRADE BELOW AT ANY POINT WITHIN 36 INCHES (914 MM)
 HORIZONTALLY TO THE EDGE OF THE OPEN SIDE. GUARDS SHALL
 BE ADEQUATE IN STRENGTH AND ATTACHMENT IN ACCORDANCE
 WITH SECTION 1607.8.
  
 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2016-07-01 Cont ID  
Sent By Mgonzale Date 2016-07-01 Time   Rev Time 1.00
Received By mgonzale Date 2016-07-01 Time   Sent To Z
Notes
2016-07-01 10:58:17NO CONFLICT WITH CITY UTILITIES.
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 PUBLIC WORKS DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-09-01 Cont ID  
Sent By   Date 2016-09-01 Time 08:00 Rev Time 0.00
Received By lmarchan Date 2016-08-19 Time 12:35 Sent To  
Notes
2016-08-22 12:35:55RESUB ROUTED TO JROACH VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-07-06 Cont ID  
Sent By jwitmer Date 2016-07-06 Time 10:28 Rev Time 0.00
Received By jwitmer Date 2016-06-22 Time 10:09 Sent To Z
Notes
2016-07-05 17:55:307/5 TO JW DESK
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2016-08-31 Cont ID  
Sent By jroach Date 2016-08-31 Time 14:08 Rev Time 0.00
Received By jroach Date 2016-08-31 Time 14:08 Sent To B
Notes
2016-08-23 13:39:28ROUTED TO JOHN ROACH

Review Stop Z ZONING
Rev No 1 Status P Date 2016-06-28 Cont ID  
Sent By jwitmer Date 2016-07-06 Time 10:29 Rev Time 0.00
Received By jroach Date 2016-06-28 Time 09:51 Sent To ENG
Notes
***NONE***