Plan Review Details - Permit 16061261
| Plan Review Stops For Permit 16061261 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-07-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-07-01 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-07-01 |
Time |
12:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-06-30 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-06-30 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-06-30 |
Time |
16:20 |
Sent To |
B |
|
| Notes |
| 2016-06-30 17:03:17 | REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | | | | - WATER SKIMMER DEVICE MUST COMPLY WITH NEC 680.26(C) | | | POOL WATER BONDING. ( RED LINED ON PLANS ) | | | | | | AN INTENTIONAL BOND OF A MINIMUM CONDUCTIVE SURFACE | | | AREA OF 5800 MM2 (9 IN.2) SHALL BE INSTALLED IN CONTACT | | | WITH THE POOL WATER. | | | THIS BOND SHALL BE PERMITTED TO CONSIST OF PARTS THAT | | | ARE REQUIRED TO BE BONDED IN 680.26(B). |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2016-06-30 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-06-30 |
Time |
05:35 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-06-30 |
Time |
05:35 |
Sent To |
|
|
| Notes |
| 2016-06-30 05:36:45 | GAS PLAN REVIEW | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-07-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-07-01 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-06-22 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2016-06-22 13:40:41 | ROUTED TO ZONING |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-06-30 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2016-06-30 |
Time |
05:34 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-06-30 |
Time |
05:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-06-23 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2016-06-23 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-06-23 |
Time |
13:12 |
Sent To |
P |
|
| Notes |
| 2016-06-23 13:13:24 | 6/23/16- PASSED | | | | | | 1. POOL EQUIPMENT MEETS SETBACK REQUIREMENTS 4FT. FROM | | | THE SIDE PROPERTY LINE. | | | 2. POOL SIDE SETBACK IS 33FT. AND 30FT. MEETING THE | | | 5FT. SETBACK REQUIREMENT. | | | 3. POOL REAR SETBACK IS 5FT. POOL ACTUAL SETBAK IS | | | 23FT. MEETING THIS REQUIREMENT. | | | | | | NATHAN WIRA |
|
|
|