| Plan Review Stops For Permit 16061232 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-06-29 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2016-06-29 |
Time |
06:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-06-29 |
Time |
05:58 |
Sent To |
|
|
| Notes |
| 2016-06-29 06:18:26 | BUILDING PROVISO: | | | 2014 FBC-ACCESSIBILITY CODE 703.2 RAISED CHARACTERS. | | | RAISED CHARACTERS SHALL COMPLY WITH 703.2 AND SHALL BE | | | DUPLICATED IN BRAILLE COMPLYING WITH 703.3. RAISED | | | CHARACTERS SHALL BE INSTALLED IN ACCORDANCE WITH 703.4. | | | 703.4 INSTALLATION HEIGHT AND LOCATION. SIGNS WITH | | | TACTILE CHARACTERS SHALL COMPLY WITH 703.4. | | | | | | 703.4.1 HEIGHT ABOVE FINISH FLOOR OR GROUND. | | | TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES | | | (1220 MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND | | | SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST | | | TACTILE CHARACTER AND 60 INCHES (1525 MM) MAXIMUM ABOVE | | | THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE | | | BASELINE OF THE HIGHEST TACTILE CHARACTER. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2016-09-02 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-09-02 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-09-02 |
Time |
14:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-08-12 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-08-12 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-08-12 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2016-08-12 11:08:24 | PROVISO- APPROVED PENDING BELOW: | | | | | | NEED 1 MORE COPY OF NEW ELECTRICAL SHEET AND NEED TO | | | REMOVE VOID SHEET AND INSERT NEW ONE | | | | | | VAL PEREZ | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-07-05 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-07-05 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-07-02 |
Time |
12:05 |
Sent To |
|
|
| Notes |
| 2016-07-05 08:54:21 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 NEC | | | COMMENTS: | | | | | | 1. UPDATE ALL CODE REFERENCES SHOWN ON SHEET E.01 TO | | | SHOW FLORIDA BUILDING CODE 2014 5TH EDITION AND AS | | | STATED ABOVE. | | | 2. GENERAL NOTES- PROVIDE A BLOCK NOTE INDICATING THE | | | REQUIRED SEPARATE PERMITS AND DATA CUT SHEET SUBMITTALS | | | FOR GENERATOR ALL LOW VOLTAGE SYSTEMS TO INCLUDE, PHONE | | | AND DATA, SIGNAGE ETC. A NOTE WILL SUFFICE. | | | 3. PLEASE LABEL RECEPTACLE IN TO BE GFCI PROTECTED PER | | | NEC 210.8B5- IF WITHIN 6FT OF SINK ALL TO BE GFCI. | | | 4. PLEASE LABEL RECEPTACLE IN PREP AREA ALL TO BE GFCI | | | PROTECTED PER NEC 210.8B5- IF WITHIN 6FT OF SINK, ALL | | | TO BE GFCI. | | | 5. ADDRESS FIRE AND MECHANICAL COMMENTS RELATED TO THE | | | ELECTRICAL SCOPE OF WORK. | | | 6. PROVIDE MANUFACTURED DATA SHEETS FOR THE NEW | | | TANKLESS WATER HEATER SHOWN. FBC 107.3.5. ALSO SHOW ON | | | ELECTRICAL PANEL SCHEDULE CALCULATION. | | | 7. ALL NEW DEVICES TO REFLECT CIRCUIT DESIGNATIONS ID. | | | FBC 107.3.5 | | | 8. NOTE SHOWN IS MISLEADING, STATES THAT NO NEW WORK IS | | | BEING PERFORMED BUT NEW DEVICES SHOWN. PLEASE CORRELATE | | | NOTES. | | | 9. FURTHER COMMENTS MAY FOLLOW. PLEASE FEEL FREE TO | | | CONTACT ME SHOULD YOU HAVE ANY QUESTIONS REGARDING THIS | | | PROJECT. | | | | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2016-06-23 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2016-06-23 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2016-06-23 |
Time |
12:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2016-09-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-09-09 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-09-08 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2016-09-09 09:37:48 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
F |
Date |
2016-09-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-09-07 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-08-26 |
Time |
11:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-08-23 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-08-23 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-08-08 |
Time |
15:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-07-05 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-07-05 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-06-21 |
Time |
10:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2016-06-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-06-29 |
Time |
06:06 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-06-29 |
Time |
06:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2016-09-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-09-09 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-09-09 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2016-09-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-09-07 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-09-07 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2016-09-07 14:26:02 | 3RD REVIEW FBC-2014 MECHANICAL | | | PERMIT #16061232 | | | 9/7/16 | | | | | | 1) THE REVISED ENERGYGAUGE COMPLIANCE SUBMITTAL LISTS | | | DATA FOR TWO 4-TON AC SYSTEMS AT 16 AND 15 SEER, | | | HOWEVER THE REVISED HVAC PLAN INDICATES A 3-TON SYSTEM | | | AT 11.8 EER. PLEASE CORRECT AND NOTE THAT THE | | | OWNER/AGENT SHALL PROVIDE HIS/HER SIGNATURE AND DATE ON | | | THE CERTIFICATIONS PAGE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-08-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-08-16 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-08-16 |
Time |
13:54 |
Sent To |
P |
|
| Notes |
| 2016-08-16 14:14:01 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #16061232 | | | 8/16/16 | | | | | | 1) 2ND REQUEST FOR MINIMUM VENTILATION CALCULATIONS- | | | SEE COMMENT #1 FROM THE 1ST REVIEW. | | | | | | 2) THE ENERGYGAUGE CALCULATION SUBMITTAL IS A REDUCED | | | SIZE COPY, ALL ENERGY COMPLIANCE DOCUMENTS TO BE | | | SUBMITTED SHALL BE ORIGINAL COPIES, AND SHALL BEAR THE | | | ORIGINAL SIGNATURES AND REGISTRATION NUMBERS OF THE | | | DESIGN PROFESSIONALS- SECTION C103.1.1.1.2 FBC-14 | | | ENERGY CONSERVATION. ADDITIONALLY, THE BUILDING'S | | | OWNER, THE OWNER'S ARCHITECT, OR THE OTHER AUTHORIZED | | | AGENT LEGALLY DESIGNATED BY THE OWNER SHALL CERTIFY | | | THAT THE BUILDING IS IN COMPLIANCE BY PROVIDING | | | SIGNATURES- C103.1.1.2. | | | | | | 3) THE SUBMITTED HVAC LOAD ANALYSIS PREPARED BY KO | | | DESIGN IS FOR DULCE PECATTO INC. 2523 DUDLEY DR. IS NOT | | | FOR THIS PROPOSED PROJECT AT 4047 OKEECHOBEE RD. PLEASE | | | NOTE THAT ONLY THE DESIGN PROFESSIONAL OF RECORD OR THE | | | INSTALLING AC CONTRACTOR IS PERMITTED TO DESIGN AC | | | PLANS AND SPECIFICATIONS PER SECTION 105.3.1.2 FBC-14 | | | BUILDING. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-06-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-06-24 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-06-24 |
Time |
12:08 |
Sent To |
|
|
| Notes |
| 2016-06-24 12:15:24 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #16061232 | | | 6/24/16 | | | | | | 1) REFER TO SECTION 809.2 FBC-14 EXISTING BUILDING CODE | | | AND PROVIDE: | | | | | | A) MINIMUM VENTILATION CALCULATIONS FOR ALL ROOMS AND | | | SPACES PER TABLE 403.3 FBC-14 MECHANICAL. | | | | | | B) AC COOLING AND HEATING CALCULATIONS. BECAUSE OF THE | | | CHANGE IN USE OF THE SPACE RESULTING IN AN INCREASED | | | OCCUPANT LOAD, AND THE ADDITION OF HEAT PRODUCING | | | APPLIANCES AND EQUIPMENT, IT NEEDS TO BE VERIFIED THAT | | | THE EXISTING AC SYSTEM HAS THE CAPACITY TO HANDLE THE | | | INCREASED LOADS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2016-09-06 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-09-06 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-09-06 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2016-09-06 09:30:34 | PLUMBING PROVISO | | | 1. PROVIDE MANUFACTURE INSTALLATION GUIDE FOR GREASE | | | INTERCEPTOR. REQUIRED FOR FINAL INSPECTION. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2016-08-23 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-08-23 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-08-23 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2016-08-23 16:00:35 | 2NDT REVIEW | | | | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | | | | PLUMBING COMMENTS: 2ND REQUEST | | | | | | 1. A GREASE INTERCEPTOR IS REQUIRED FOR 3 COMP SINK AND | | | MOP SINK. PER FBC PL SEC. 1003.3.1 | | | 2. THE 3 COMP SINK SHALL DRAIN INDIRECTLY INTO SANITARY | | | SYSTEM. FBC PL SEC. 802.1.8 FOOD UTENSILS, DISHES, POTS | | | AND PANS SINKS. | | | SINKS USED FOR THE WASHING, RINSING OR SANITIZING OF | | | UTENSILS, DISHES, POTS, PANS OR SERVICE WARE USED IN | | | THE PREPARATION, SERVING OR EATING OF FOOD SHALL | | | DISCHARGE INDIRECTLY THROUGH AN AIR GAP OR AN AIR BREAK | | | TO THE DRAINAGE SYSTEM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-07-05 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-07-05 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-07-05 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2016-07-05 15:41:23 | 1ST REVIEW | | | | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | | | | PLUMBING COMMENTS: | | | 1. A GREASE INTERCEPTOR IS REQUIRED FOR 3 COMP SINK AND | | | MOP SINK. PER FBC PL SEC. 1003.3.1 | | | 2. THE 3 COMP SINK SHALL DRAIN INDIRECTLY INTO SANITARY | | | SYSTEM. FBC PL SEC. 802.1.8 FOOD UTENSILS, DISHES, POTS | | | AND PANS SINKS. | | | SINKS USED FOR THE WASHING, RINSING OR SANITIZING OF | | | UTENSILS, DISHES, POTS, PANS OR SERVICE WARE USED IN | | | THE PREPARATION, SERVING OR EATING OF FOOD SHALL | | | DISCHARGE INDIRECTLY THROUGH AN AIR GAP OR AN AIR BREAK | | | TO THE DRAINAGE SYSTEM. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-08-12 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2016-08-12 |
Time |
14:57 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2016-08-12 |
Time |
14:57 |
Sent To |
|
|
| Notes |
|
|