Plan Review Details - Permit 16061207
Plan Review Stops For Permit 16061207
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-08-18 Cont ID  
Sent By tklarge Date 2016-08-18 Time 06:35 Rev Time 0.00
Received By tklarge Date 2016-08-18 Time 06:24 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-06-24 Cont ID  
Sent By   Date 2016-06-24 Time 06:29 Rev Time 0.00
Received By jwitmer Date 2016-06-23 Time 16:46 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-07-21 Cont ID  
Sent By mvaldes Date 2016-07-21 Time 11:46 Rev Time 0.00
Received By mvaldes Date 2016-07-21 Time 10:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-06-22 Cont ID  
Sent By mvaldes Date 2016-06-22 Time 18:27 Rev Time 0.00
Received By mvaldes Date 2016-06-22 Time 17:15 Sent To  
Notes
2016-06-22 18:29:47JOB PERMIT NUMBER: 16061207
 JOB ADDRESS: 501 S FLAGLER DR
 WEST PALM BEACH FLORIDA
 DATE: JUNE 22 2016
  ELECTRICAL PLAN REVIEW COMMENTS
  
 THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION
 HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF
 THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC,
 (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST
 PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF
 SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED.
  
 - SITE LIGHTING, FIRE ALARM, ACCESS CONTROL, AND LOW
 VOLTAGE (TELEPHONE, DATA, & CAMERAS) SHALL BE SUBMITTED
 UNDER A SEPARATE PERMIT WITH SEPARATE SHOP DRAWINGS.
 - SHEET E0.03 FOR PROPER CODE REQUIREMENT REFERENCING
 THE APPLICABLE WIND LOAD DESIGN IS 170 MPH VERIFY FBC-
 1603.1.4
 - SHEET 3.00 CONFERENCE ROOM AND COLLABORATION TABLES
 DATA & POWER OUTLETS, RACEWAY OR ENCLOSURES SHALL BE
 SEPARATE UNLESS SAME INSULATION VOLTAGE RATING OF
 CONDUCTORS IS USED NEC 300.3(C)(1). BARRIERS MAY BE
 INSTALLED IN BOXES IN ACCORDANCE WITH NEC 725 ARTICLES.
 - SHEET 3.00 EMPLOYEE SOCIAL CENTER SHALL HAVE GFCI
 PROTECTION ON ALL RECEPTACLES WITHIN 6? OF THE
 COUNTER-TOP SINK. NEC 210.8(B)(5) MARK ON PLANS.
 - GENERAL COMMENT, WORKING CLEARANCE AND ILLUMINATION
 IN THE ELECTRICAL ROOM SHALL COMPLY WITH NEC 110.26 AND
 CHECKED AT THE TIME OF INSPECTION. LIGHTING MANDATORY
 CONTROLS, ENERGY ALLOWANCE LEVELS, AND EMERGENCY
 ILLUMINATION ARE IN COMPLIANCE WITH THE FBC, NEC,
 FBC-E.
 - PANEL SCHEDULE TO INCLUDE AIC AND SCR OF ELECTRICAL
 EQUIPMENT NEC 110.10, 110.9. ADD A NOTE IN THE RISER
 DIAGRAM FOR ARC-FLASH WARNING LABELS & AVAILABLE FAULT
 CURRENT MARKINGS. BOTH IDENTIFICATION PLAQUES SHALL BE
 SUITABLE FOR THE ENVIRONMENT INVOLVED NEC 110.16,
 110.24
  
 PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE
 MENTIONED DEFICIENCIES.
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE
 LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE
 STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD
 INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE
 OR ACTION TO SAME. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE
 PREVIOUSLY REVIEWED SHEETS FOR COMPARISON.
 CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 FBC 2014 5TH ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2016-06-23 Cont ID  
Sent By wjolin Date 2016-06-23 Time 12:10 Rev Time 0.00
Received By wjolin Date 2016-06-23 Time 11:58 Sent To  
Notes
2016-06-23 12:10:19501 SOUTH FLAGLER DRIVE
 PERMIT #16061207
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE
 INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER
 SYSTEM AND/OR FIRE ALARM SYSTEM.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-08-18 Cont ID  
Sent By tklarge Date 2016-08-18 Time 06:35 Rev Time 0.00
Received By tklarge Date 2016-08-16 Time 16:13 Sent To  
Notes
2016-08-16 16:13:17RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-08-06 Cont ID  
Sent By tklarge Date 2016-08-06 Time 06:33 Rev Time 0.00
Received By tklarge Date 2016-07-19 Time 13:21 Sent To  
Notes
2016-07-20 13:21:53B32

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-06-24 Cont ID  
Sent By   Date 2016-06-24 Time 06:29 Rev Time 0.00
Received By cpuell Date 2016-06-21 Time 14:56 Sent To  
Notes
2016-06-21 14:56:59B26

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-07-21 Cont ID  
Sent By jvalido Date 2016-07-21 Time 10:24 Rev Time 0.00
Received By jvalido Date 2016-07-21 Time 09:55 Sent To  
Notes
2016-07-21 10:26:35ROUTE TO MARIO V.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-06-22 Cont ID  
Sent By jvalido Date 2016-06-22 Time 13:58 Rev Time 0.00
Received By jvalido Date 2016-06-22 Time 09:51 Sent To  
Notes
2016-06-22 13:58:07CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 (1) VAV #8 ON SHEET M2.00 DOES NOT MEET THE CFM SUPPLY
 OUTLET QUANTITIES.
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2016-08-18 Cont ID  
Sent By tklarge Date 2016-08-18 Time 06:24 Rev Time 0.00
Received By tklarge Date 2016-08-18 Time 06:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2016-08-06 Cont ID  
Sent By tklarge Date 2016-08-06 Time 06:33 Rev Time 0.00
Received By tklarge Date 2016-08-06 Time 06:18 Sent To  
Notes
2016-08-06 06:33:301) SHT. A11.02 - DETAIL #2 - THE SINK IN THE SOCIAL
 CENTER SHALL BE LOCATED A MAXIMUM OF 34 INCHES ABOVE
 THE FINISHED FLOOR PER FBC-ACCESS. SECS.212, 606.
 2) WHERE THE HORIZONTAL BRANCH IS LOCATED MORE THAN
 FOUR BRANCH INTERVALS FROM THE TOP OF THE STACK, THE
 HORIZONTAL BRANCH SHALL BE PROVIDED WITH A RELIEF VENT
 THAT SHALL CONNECT TO A VENT STACK OR STACK VENT PER
 2014 FBC-PLUMBING SEC.918.3.1. INDICATE ON THE PLANS
 WHAT FLOOR THIS SUITE IS ON AND HOW MANY FLOORS ARE IN
 THIS BUILDING.
 3) HOT OR TEMPERED WATER SHALL BE SUPPLIED TO THE SINK
 IN THE SOCIAL CENTER PER 2014 FBC-PLUMBING SEC.607.1.
 4) SUBMIT A WATER AND SANITARY RISER PER WPB AMEND. TO
 FBC. SEC. 107.3.5.1.3.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-06-23 Cont ID  
Sent By gearl Date 2016-06-23 Time   Rev Time 0.00
Received By gearl Date 2016-06-23 Time 13:45 Sent To  
Notes
2016-06-23 13:45:16NEED TO SHOW SANITARY PIPING AND WATER PIPING ON
 DRAWING FOR SOCIAL ROOM AREA