| Plan Review Stops For Permit 16061205 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-08-12 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2016-08-12 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
|
Date |
2016-08-12 |
Time |
16:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-07-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-07-21 |
Time |
07:45 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2016-07-21 |
Time |
07:01 |
Sent To |
|
|
| Notes |
| 2016-07-21 07:38:55 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16061205 | | | ADD: 501 FLAGLER DR./ ????? SUITE NOR FLOOR LEVEL GIVEN | | | CONT: TBD | | | TEL: 904-419-1001 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: THURS. JULY 21/ 2016 | | | ACTION: DENIED | | | | | | 1) PLEASE PROVIDE EITHER THE SUITE NUMBER OR FLOOR THE | | | WORK COVERED UNDER THIS PERMIT WILL OCCUR. | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION 107.2.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED. | | | | | | 2) SHEET A02.01 SHOWS STAIRS 120, WITHIN THE WALL THERE | | | IS A NOTE # 7 INFILL WALL TO MATCH ADJACENT PARTITION. | | | THE PLAN DOES NOT INDICATE IF THIS IS A ONE HOUR OR TWO | | | HOUR RATED VERTICAL EXIT. | | | 2014 FBC-B 1022.2 CONSTRUCTION. ENCLOSURES FOR INTERIOR | | | EXIT STAIRWAYS AND RAMPS SHALL BE CONSTRUCTED AS FIRE | | | BARRIERS IN ACCORDANCE WITH SECTION 707 OR HORIZONTAL | | | ASSEMBLIES CONSTRUCTED IN ACCORDANCE WITH SECTION 711, | | | OR BOTH. INTERIOR EXIT STAIRWAY AND RAMP ENCLOSURES | | | SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 2 | | | HOURS WHERE CONNECTING FOUR STORIES OR MORE AND NOT | | | LESS THAN 1 HOUR WHERE CONNECTING LESS THAN FOUR | | | STORIES. | | | | | | 3) SHEET A2.01 STAIR 120 AND THE DOOR INTO THE STAIR. | | | IT IS UNKNOWN IF THERE IS ANOTHER FLOOR BENEATH THIS | | | FLOOR WHERE YOU EXIT THE STAIR ENCLOSURE OR IF THIS IS | | | THE FLOOR OF EXIT DISCHARGE. IF THIS IS THE FLOOR OF | | | EXIT DISCHARGE FROM THE VERTICAL EXIT THEN THE DOOR | | | SHOULD BE AN OUTSWING DOOR. 1008.1.2. | | | | | | 4) SHEET A2.01 STAIR DOOR 120 DOES NOT SHOW ANY FIRE | | | RATING SEE DOOR SCHEDULE ON SHEET A00.30. 2014 FBC-B | | | TABLE 716.5. | | | | | | 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2016-08-24 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-08-24 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-08-24 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2016-08-11 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-08-11 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-08-11 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2016-08-11 12:45:28 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 | | | COMMENTS: | | | | | | 1. PLEASE NOTE AND CLARIFY THAT THERE IS TWO EOR | | | SIGNING ELECTRICAL CONSTRUCTION DOCUMENTS SUBMITTED | | | UNDER REVIEW. HAVE EITHER ONE OR THE OTHER SIGN ALL | | | SHEETS RELATED TO ELECTRICAL DESIGN. ORIGINAL EOR WAS | | | BOBAK SHAHNAMI, NOW MANUEL HERNANDEZ IS SIGNING TOP | | | SHEET. FBC 105.3.1.2(5) FLORIDA STATUE. | | | 2. PLEASE FEEL FREE TO CONTACT ME SHOULD YOU HAVE ANY | | | QUESTIONS REGARDING THIS PROJECT. | | | | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-07-02 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-07-02 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-07-02 |
Time |
07:39 |
Sent To |
|
|
| Notes |
| 2016-07-02 07:57:52 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 NEC | | | COMMENTS: PROVISO | | | | | | 1. PLEASE PROVIDE LEGIBLE GENERAL NOTES ON SHEET E | | | 3.00. AND PROVIDE A GENERAL NOTE TO INDICATE REQUIRED | | | SEPARATE PERMIT FOR ALL LOW VOLTAGE SYSTEMS. | | | 2. PLEASE FEEL FREE TO CONTACT ME SHOULD YOU HAVE ANY | | | QUESTIONS REGARDING THIS PROJECT. | | | | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2016-08-08 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-08-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-08-08 |
Time |
16:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2016-07-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-07-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-07-15 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2016-07-15 16:29:34 | THIS RESUBMITTED PLAN WAS REVIEWED AND FAILED BY PETER | | | LEDUC, FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) SHEET 01.02 - DOOR 100 APPEARS TO BE INSTALLED INTO | | | A FIRE RATED WALL; HOWEVER, THE PLAN AND THE DOOR | | | SCHEDULE DOES NOT INDICATE ANY FIRE RATING. | | | | | | PLEASE CORRECT, VERIFY OR JUSTIFY. | | | | | | 2) SHEET E 0.01 - THERE IS NO INDICATION THAT THE FIRE | | | ALARM WORK SHALL BE SUBMITTED, INSTALLED AND TEST UNDER | | | SEPARATE SHOP DRAWINGS BY A CERTIFIED LIFE SAFETY | | | CONTRACTOR. | | | | | | 3) SHEET 00.30 - DOOR 104 HARDWARE IS INDICATED AS | | | KEYPAD LEVER. THIS DOOR SHALL NO BE LOCKED AGAINST | | | EGRESS AND SHALL COMPLY WITH NFPA 101, CHAPTER 7. | | | | | | 7.2.1.5 LOCKS, LATCHES, AND ALARM DEVICES. | | | 7.2.1.5.1 DOOR LEAVES SHALL BE ARRANGED TO BE OPENED | | | READILY FROM THE EGRESS SIDE WHENEVER THE BUILDING IS | | | OCCUPIED. | | | | | | 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE | | | OF A KEY, A TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR | | | OPERATION FROM THE EGRESS SIDE. | | | | | | PLEASE CONFIRMAND PROVIDE AN INDICATING NOTE. | | | | | | 4) SHEET 00.30 - DOOR 100 AND APPLICABLE HARDWARE IS | | | NOT INDICATED ON THE DOOR SCHEDULE. | | | | | | PLEASE CORRECT. | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2016-06-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-06-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-06-23 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2016-06-23 14:37:57 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | 1) THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | | | | 2) ANY AND ALL WORK ON THE FIRE ALARM AND FIRE | | | SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP | | | DRAWINGS AND BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | 3) ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | | AND COMPLETE PROTECTION IS RETURNED. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2016-08-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-08-24 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-08-23 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2016-08-23 13:53:39 | RESUB ROUTED TO VPEREZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-08-12 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2016-08-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2016-08-02 |
Time |
13:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-07-21 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2016-07-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-06-29 |
Time |
14:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-06-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-06-24 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-06-21 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2016-06-24 11:34:10 | 6/24/2016 PLANS SUBMITTED ARE A MISTAKE, THE SAME WORK | | | AS COVERED UNDER 16061205. I'VE SPOKE WITH ASHLEY | | | TAYLOR AT H&T CONSULANTS. THEY WILL RESUBMIT THE | | | CORRECT PLANS TO CONTINUE THE REVIEW. WE SHOULD KEEP | | | THE SUBMITTAL DATE OF JUNE 21/ 2016 ONCE THE CORRECTED | | | PLANS ARE RESUBMITTED. J. W. | | 2016-06-21 15:07:59 | B24 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2016-08-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-08-24 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-08-24 |
Time |
11:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-08-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-08-05 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-08-05 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2016-08-05 12:35:46 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #16061205 | | | 8/5/16 | | | | | | 1) COMMENT #9 FROM THE 1ST REVIEW STILL EXISTS- SHEETS | | | M0.01, M0.02, HAVE COPIED ELECTRONIC SEALS. ELECTRONIC | | | SEALS ARE FOR DIGITAL TRANSFER AND CANNOT BE USED TO | | | CERTIFY PAPER PLANS. PLEASE PROVIDE AN ORIGINAL RAISED | | | OR INK SEAL AS REQUIRED BY FORIDA STAUTE AND FAC | | | 61G1-23.002 | | | | | | 2) THERE ARE TWO DIFFERENT M0.01 PLAN SHEETS IN THE | | | SETS AND THE INDEX NUMBERS ON THE PLANS DO NOT MATCH | | | THE NUMBERS IN THE INDEX.- PLEASE CORRECT THESE | | | MISTAKES. | | | | | | 3) M2.00: THE SPACES SERVED FOR VAV 11 IN THE SCHEDULE | | | ARE NOT CORRECT. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-07-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-07-05 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-07-05 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2016-07-05 11:51:24 | 1ST REVIEW: FBC 2014 MECHANICAL, EXISTING BUILDING | | | PERMIT #16061205 | | | 7/5/16 | | | | | | 1) REFER TO SECTION 809.2 FBC-14 EXISTING BUILDING CODE | | | AND PROVIDE MINIMUM VENTILATION CALCULATIONS FOR ALL | | | ROOMS AND SPACES PER TABLE 403.3 FBC-14 MECHANICAL. | | | PROVIDE A SCHEDULE ON THE PLAMNS INDICATING THE | | | REQUIRED AND PROVIED CFMS OF O/A AIR. | | | | | | 2) SHEETS M0.01 & M2.00: PLEASE PLACE KEY NOTES AT EACH | | | VAV BOX LOCATION SHOWN ON THE PLANS TO CLARIFY THE | | | SCOPE OF WORK. | | | | | | 3) M2.00: MANY OF THE RETURN REGISTERS SHOWN ON THE | | | PLANS DO NOT HAVE LABELS OR CFM QUANTITIES NOTED- | | | PLEASE CORRECT. | | | | | | 4) M2.00: INDICATE HOW AIR IS BEING RETURNED FROM THE | | | VESTIBULE. | | | | | | 5) M2.00: BRANCH DUCT SIZES FOR VAV 9 NOT SHOWN. | | | | | | 6) M2.00: THE VAV SCHEDULE IS TITLED "EXISTING" HOWEVER | | | MANY OF THE BOXES ARE NEW- MPLEASE CORRECT. | | | | | | 7) M2.00: THE SPACES SERVED FOR VAV'S 20 & 21 ARE | | | REVERSED IN THE SCHEDULE. | | | | | | 8) M2.00: IDENTIFY THE SPACES BEING SERVED BY VAV'S 8 & | | | 12 ON THE PLAN. | | | | | | 9) THE MECHANICAL PLAN SHEETS HAVE COPIED ENGINEER'S | | | SEALS: ORIGINAL SIGNATURES AND SEALS ARE REQUIRED BY | | | FLORIDA STATUTE, AND SECTION 61G15-23.002 FLORIDA | | | ADMINISTRATIVE CODE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|