Plan Review Details - Permit 16061157
Plan Review Stops For Permit 16061157
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-07-14 Cont ID  
Sent By cthroop Date 2016-07-14 Time 08:34 Rev Time 0.00
Received By cthroop Date 2016-07-14 Time 08:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-06-28 Cont ID  
Sent By cthroop Date 2016-06-28 Time 10:13 Rev Time 0.00
Received By cthroop Date 2016-06-28 Time 10:13 Sent To  
Notes
2016-06-28 10:18:00BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 ACTION: DENIED
 DATE: 6/28/16
  
 1. CANNOT READ PLAN PG SP1.
 2. SPECIFY CONCRETE STRENGTH FOR FOUNDATION.
 3. SPECIFY LENGTH OF ANCHOR BOLTS AT FOUNDATION.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-07-13 Cont ID  
Sent By mvaldes Date 2016-07-13 Time 18:32 Rev Time 0.00
Received By mvaldes Date 2016-07-13 Time 09:04 Sent To B
Notes
2016-07-13 18:32:53ROUTED TO CHRIS THROOP.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-06-23 Cont ID  
Sent By mvaldes Date 2016-06-23 Time 14:00 Rev Time 0.00
Received By mvaldes Date 2016-06-23 Time 14:00 Sent To  
Notes
2016-06-23 14:02:39REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
 - C405.2.4 EXTERIOR LIGHTING CONTROLS. (PROVISO)
 LIGHTING NOT DESIGNATED FOR DUSK-TO-DAWN OPERATION
 SHALL BE CONTROLLED BY EITHER A COMBINATION OF A
 PHOTOSENSOR AND A TIME SWITCH, OR AN ASTRONOMICAL TIME
 SWITCH. LIGHTING DESIGNATED FOR DUSK-TO-DAWN OPERATION
 SHALL BE CONTROLLED BY AN ASTRONOMICAL TIME SWITCH OR
 PHOTOSENSOR.
 ALL TIME SWITCHES SHALL BE CAPABLE OF RETAINING
 PROGRAMMING AND THE TIME SETTING DURING LOSS OF POWER
 FOR A PERIOD OF AT LEAST 10 HOURS.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-07-14 Cont ID  
Sent By cthroop Date 2016-07-14 Time 08:34 Rev Time 0.00
Received By cthroop Date 2016-07-12 Time 13:45 Sent To  
Notes
2016-07-12 13:46:44RESUB ROUTED TO MVALDES

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-06-28 Cont ID  
Sent By cthroop Date 2016-06-28 Time 10:13 Rev Time 0.00
Received By cthroop Date 2016-06-20 Time 10:13 Sent To  
Notes
2016-06-21 10:14:24ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 1 Status P Date 2016-06-22 Cont ID  
Sent By njwira Date 2016-06-22 Time 12:09 Rev Time 0.00
Received By njwira Date 2016-06-22 Time 12:09 Sent To E
Notes
2016-06-22 12:10:06ZBA3322