Plan Review Details - Permit 16060841
Plan Review Stops For Permit 16060841
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-08-16 Cont ID  
Sent By jwitmer Date 2016-08-16 Time 14:41 Rev Time 0.00
Received By jwitmer Date 2016-08-16 Time 09:17 Sent To E
Notes
2016-08-16 14:45:19BUILDING PROVISO:
 NOTE DOOR 04 IS OK FOR CURRENT SWING AS SHOWN. PERMIT #
 16070444 IS FOR A TENANT DEMISSING WALL & TENANTCY WITH
 AN OCCUPANT LOAD OF LESS THAN 50 OCCUPANTS,
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-06-17 Cont ID  
Sent By jwitmer Date 2016-06-17 Time 09:03 Rev Time 0.00
Received By jwitmer Date 2016-06-17 Time 07:43 Sent To  
Notes
2016-06-17 09:03:26BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16060841
 ADD: 525 OKEECHOBEE BLVD. 17 FLOOR /COMMON CORRIDOR7
 TENAT DEMISSING WALLS
 CONT: HOLT LEE
 TEL: 954-725-4881
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRI. JUNE 17/ 2016
 ACTION: DENIED
  
 1) SHEETS A1.1 & A1.2 BOTH SHOW DOOR # 4 SWINGS AGAINST
 THE DIRECTION OF EGRESS TRAVEL. THIS TENANT SPACE IS
 APPROXIMATELY 6,500 SQ. FT. OR 65 OCCUPANTS MINIMUM,
 WITH ASSEMBLY USAGE COMPONENTS THE OCCUPANT LOAD COULD
 BE HIGHER. PLEASE SHOW COMPLIANCE WITH 2014 FBC-B
 SECTION 1008.1.2 DOOR SWING.
 DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL
 WHERE SERVING A ROOM OR AREA CONTAINING AN OCCUPANT
 LOAD OF 50 OR MORE PERSONS OR A GROUP H OCCUPANCY.
  
 2) SHEET A3.1 DETAIL A4 INDICATES A 1 HOUR FIRE WALL.
 THIS DETAIL DOES NOT INDICATE WHAT TYPE OF DECK IS
 ABOVE A B-DECK (CORRIGATED) OR A CONCRETE DECK? PLEASE
 PROVIDE THIS INFORMATION AND THE TOP PLATE ANCHORING
 DETAIL? 2014 FBC-B 707.8 JOINTS. JOINTS MADE IN OR
 BETWEEN FIRE BARRIERS, AND JOINTS MADE AT THE
 INTERSECTION OF FIRE BARRIERS WITH UNDERSIDE OF A
 FIRE-RESISTANCE RATED FLOOR OR ROOF SHEATHING, SLAB, OR
 DECK ABOVE SHALL COMPLY WITH SECTION 715.
  
 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-08-18 Cont ID  
Sent By albarran Date 2016-08-18 Time 09:50 Rev Time 0.00
Received By albarran Date 2016-08-17 Time 16:29 Sent To I
Notes
2016-08-18 09:51:43ALL PREVIOUSLY MENTIONED DEFICIENCIES HAVE BEEN
 SATISFACTORILY ADDRESSED.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-07-19 Cont ID  
Sent By vperez Date 2016-07-19 Time 12:10 Rev Time 0.00
Received By albarran Date 2016-06-27 Time 12:09 Sent To  
Notes
2016-07-19 14:18:27ELECTRICAL REVIEW NOTES
 REVIEWED FOR COMPLIANCE WITH: 5TH EDITION FBC 2014 &
 NFPA 70 2011 (NEC)
  
 JOB NAME: NEW COMMON CORRIDOR FOR 17TH FLOOR
 JOB ADDRESS: 525 OKEECHOBEE BLVD.
 DESCRIPTION: COMMERCIAL DEMO AND SUBSEQUENT ALTERATION
 ON TWO SEPARATE PERMITS.
 MAST. PERMIT: 16060841/16060841
 REVISION: N/A
  
 IN ADDITION TO THE PREVIOUS FIRE AND ELECTRICAL
 COMMENTS, PLEASE NOTE THE FOLLOWING:
 1. FBC-E405.7 REQUIRES AUTOMATIC RECEPTACLE CONTROL
 2. FBC.B1011 HAS SPECIFIC EXIT LIGHT REQUIREMENTS WHICH
 HAVE NOT BEEN MET.
 3. NEC 422.52 REQUIRES GFCI PROTECTION FOR DRINKING
 FOUNTAIN CIRCUITS. THE COVER SHEET INDICATES THAT A NEW
 ADA COMPLIANT WATER FOUNTAIN IS BEING INSTALLED, YET
 THERE IS NO MENTION OF THIS IN THE ELECTRICAL SHEETS OR
 THE ELECTRICAL PANEL SCHEDULES.
  
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER
 WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD
 CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID
 AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE
 GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  
  
  
2016-06-27 12:12:05INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011 NEC
 COMMENTS:
  
 1. ADDRESS FIRE COMMENT FOR AN ELECTRICAL APPROVAL.
 2. FURTHER COMMENTS MAY FOLLOW UPON RE-REVIEW. FEEL
 FREE TO CONTACT ME AT THE NUMBER BELOW SHOULD YOU HAVE
 ANY QUESTIONS OR CONCERN.
  
  
  
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-08-15 Cont ID  
Sent By pleduc Date 2016-08-15 Time   Rev Time 0.00
Received By pleduc Date 2016-08-15 Time 12:24 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2016-06-21 Cont ID  
Sent By pleduc Date 2016-06-21 Time   Rev Time 0.00
Received By pleduc Date 2016-06-21 Time 13:45 Sent To  
Notes
2016-06-21 14:27:59THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) SHEET A 1.1 - THE REMODEL CREATES A SIGNIFICANT
 CHANGE IN THE ELEVATOR LOBBY AREA. THERE IS NO
 INDICATION OF APPROVAL FROM THE ENGINEER OF RECORD OR
 OTHER QUALIFIED ENTITY REGARDING THE ELEVATOR LOBBY
 PROTECTION, ELEVATOR SHAFT PRESSURIZATION, SMOKE EVAC,
 SMOKE CONTROL OF THE EXISTING SYSTEMS AND THEIR EFFECT
 ON THE PROPOSED INSTALLATION.
  
 PLEASE PROVIDE A QUALIFIED AND COMPLIANT REVIEW OF THE
 EXISTING LIFE SAFETY SYSTEMS FEATURES OF THE ELEVATORS
 AND LOBBY AREA IN RELATION TO THE PROPOSED.
  
 2) SHEET A 1.1 - THE NEWLY CREATED ELEVATOR LOBBY
 CORRIDORS DO NOT INDICATE RATED OR SMOKE PARTITION
 WALLS. PLEASE PROVIDE A REVIEW INDICATING THE
 APPROPRIATE LIFE SAFETY FEATURE FOR THESE NEW WALLS.
  
 3) SHEET A 1.1 - DOOR # 4 IS INDICATED AND IS
 IN-SWINGING. IS THIS DOOR FUNCTIONING AS A REQUIRED
 EXIT?
  
 PLEASE PROVIDE A LIFE SAFETY PLAN OF THE ENTIRE SPACE
 AS THE EXISTING EXITS HAVE BEEN MODIFIED AND TO ENSURE
 PROPER OCCUPANCY LOAD EXIT REQUIREMENTS ARE MET PER
 NFPA 101, CHAPTER 7.
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-08-18 Cont ID  
Sent By albarran Date 2016-08-18 Time 09:54 Rev Time 0.00
Received By albarran Date 2016-08-08 Time 09:56 Sent To  
Notes
2016-08-18 09:55:128/18/16 PASSED ALL REVIEWS AND IS READY TO ISSUE.
 CONTRACTOR NOTIFIED VIA EMAIL. FILE SENT TO LARGE READY
 BIN "H". MA
2016-08-09 09:57:00B17
 *TRAVELLING WITH 16060842**

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-06-27 Cont ID  
Sent By vperez Date 2016-06-27 Time 12:12 Rev Time 0.00
Received By vperez Date 2016-06-27 Time 12:12 Sent To  
Notes
2016-06-14 13:06:42B17
 *TRAVELLING WITH 16060842*

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2016-06-17 Cont ID  
Sent By jwitmer Date 2016-06-17 Time 07:43 Rev Time 0.00
Received By jwitmer Date 2016-06-17 Time 07:43 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2016-06-20 Cont ID  
Sent By ccole Date 2016-06-20 Time 09:00 Rev Time 0.00
Received By ccole Date 2016-06-20 Time 09:00 Sent To  
Notes
***NONE***