Plan Review Details - Permit 16060733
Plan Review Stops For Permit 16060733
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-06-22 Cont ID  
Sent By cthroop Date 2016-06-22 Time 11:13 Rev Time 0.00
Received By cthroop Date 2016-06-22 Time 11:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-06-13 Cont ID  
Sent By skennedy Date 2016-06-13 Time 09:55 Rev Time 0.00
Received By skennedy Date 2016-06-13 Time 09:55 Sent To P
Notes
2016-06-13 10:02:461ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL
  
 553.792?BUILDING PERMIT APPLICATION TO LOCAL
 GOVERNMENT.?
 (1)?WITHIN 10 DAYS OF AN APPLICANT SUBMITTING AN
 APPLICATION TO THE LOCAL GOVERNMENT, THE LOCAL
 GOVERNMENT SHALL ADVISE THE APPLICANT WHAT INFORMATION,
 IF ANY, IS NEEDED TO DEEM THE APPLICATION PROPERLY
 COMPLETED IN COMPLIANCE WITH THE FILING REQUIREMENTS
 PUBLISHED BY THE LOCAL GOVERNMENT.
  
 YOUR APPLICATION IS INCOMPLETE AS NO PLAN IS PROVIDED
 RATHER ONLY A WRITTEN SCOPE OF WORK HAS BEEN PROVIDED.
 AT LEAST A SKETCH SHOWING THE FLOOR PLAN SHOULD BE
 INCLUDED TO ALLOW FOR DETERMINATION OF COMPLIANCE AS TO
 CLEARENCES OF FIXTURES.
  
 PROVIDE A PLAN PER FBC 107, MINIMUM PLAN REVIEW
 REQQUIREMENTS.
  
 ADDITIONALLY, PROVIDE A FLOORING UNDERLAYMENT SUBMITTAL
 TO INCLUDE PRODUCT TEST REPORTS TO DEMONSTRATE
 COMPLIANCE WITH FBC SECTIONS;
 603.1 FLAME SPREAD
 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2016-06-13 Cont ID  
Sent By skennedy Date 2016-06-13 Time 09:54 Rev Time 0.00
Received By skennedy Date 2016-06-13 Time 09:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-06-22 Cont ID  
Sent By cthroop Date 2016-06-22 Time 11:13 Rev Time 0.00
Received By cthroop Date 2016-06-21 Time 15:40 Sent To  
Notes
2016-06-21 15:40:43RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-06-14 Cont ID  
Sent By tklarge Date 2016-06-14 Time 04:23 Rev Time 0.00
Received By tklarge Date 2016-06-13 Time 09:54 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2016-06-13 Cont ID  
Sent By skennedy Date 2016-06-13 Time 09:55 Rev Time 0.00
Received By skennedy Date 2016-06-13 Time 09:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-06-22 Cont ID  
Sent By tklarge Date 2016-06-22 Time 08:58 Rev Time 0.00
Received By tklarge Date 2016-06-22 Time 08:52 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-06-14 Cont ID  
Sent By tklarge Date 2016-06-14 Time 04:22 Rev Time 0.00
Received By tklarge Date 2016-06-14 Time 04:11 Sent To  
Notes
2016-06-14 04:22:531) SUBMIT A SET OF PLANS THAT CLEARLY SHOWS THE
 LOCATION IN THE UNIT WHERE THE WORK IS BEING DONE.WPB
 AMEND. TO FBC SEC. 107.2.1.
 2) THE TUB FAUCET VALVE SHALL BE BALANCED - PRESSURE,
 THERMOSTATIC OR COMBINATION BALANCED-PRESSURE /
 THERMOSTATIC VALVE THAT COMPLIES WITH ASSE 1016 OR ASME
 A112.18.1.THE MAXIMUM TEMPERATURE OF THE WATER SHALL BE
 LIMITED TO 120 DEGREES F.2014 FPC SEC.424.3.
 3) IF A WATER - TEMPERATURE LIMITING DEVICE IS USED IT
 SHALL CONFORM TO ASSE 1070 OR CSA B125.3. 2014 FPC
 SEC.424.5.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  