Plan Review Details - Permit 16060298
Plan Review Stops For Permit 16060298
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-06-30 Cont ID  
Sent By cthroop Date 2016-06-30 Time 09:37 Rev Time 0.00
Received By cthroop Date 2016-06-30 Time 09:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-06-28 Cont ID  
Sent By skennedy Date 2016-06-28 Time 08:27 Rev Time 0.00
Received By cthroop Date 2016-06-27 Time 16:18 Sent To P
Notes
2016-06-28 08:31:56BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 DATE: 6/28/16
 ACTION: DENIED
  
 SUBMITTAL LACKS CLARITY. CANNOT DETERMINE SCOPE OF
 WORK.
 PROVIDE FLOOR PLAN WITH DEMENSIONS SIGNED BY DESIGNER.
 PROVIDE CLEARLY STATED SCOPE OF WORK SO A DETERMINATION
 CAN BE MADE AS TO THE LEVEL OF ALTERATION PROPOSED.
 NO REVIEW PERFORMED AT THIS TIME.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  
  
2016-06-27 16:39:07 
  
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2016-06-30 Cont ID  
Sent By cthroop Date 2016-06-30 Time 09:37 Rev Time 0.00
Received By cthroop Date 2016-06-30 Time 09:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-06-27 Cont ID  
Sent By skennedy Date 2016-06-27 Time 17:55 Rev Time 0.00
Received By mvaldes Date 2016-06-27 Time 17:55 Sent To B
Notes
2016-06-27 18:04:09REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
  
 - FBC 107.2.1 CLEARLRY DEFINE SCOPE OF WORK ?
 ALTERATION 1 OR 2 ? PROVIDE A FLOOR PLAN WITH
 ELECTRICAL INFORMATION.
  
 - IF WORK IN THE KITCHEN AND BATHROOMS IS BEING
 CONDUCTED THE FOLLOWING ARE THE MINIMUM REQUIREMENTS
 E3901.3
  
 SMALL APPLIANCE RECEPTACLES, E3901.6 BATHROOM,
 E3901.2.4 COUNTERTOP RECEPTACLES, E3902.1 BATHROOM
 RECEPTACLES
  
 E3902.6 KITCHEN RECEPTACLES.
2016-06-27 16:19:48NO ELECTRICAL SHOWN

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2016-06-27 Cont ID  
Sent By fmittner Date 2016-06-27 Time 13:41 Rev Time 0.00
Received By fmittner Date 2016-06-27 Time 13:41 Sent To P
Notes
2016-06-27 13:42:05SPOKE TO WARREN HAMMOND, CONFIRMED THIS IS LIMITED
 REPAIR TO ONLY DAMAGED PORTIONS REPLACEMENT WILL BE
 WITH IN KIND MATERIALS. WOOD FOR WOOD.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-06-30 Cont ID  
Sent By cthroop Date 2016-06-30 Time 09:36 Rev Time 0.00
Received By cthroop Date 2016-06-30 Time 09:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-06-30 Cont ID  
Sent By skennedy Date 2016-06-30 Time 08:18 Rev Time 0.00
Received By cpuell Date 2016-06-07 Time 14:20 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2016-06-30 Cont ID  
Sent By cthroop Date 2016-06-30 Time 09:37 Rev Time 0.00
Received By cthroop Date 2016-06-30 Time 09:37 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-06-29 Cont ID  
Sent By jvalido Date 2016-06-29 Time 15:56 Rev Time 0.00
Received By jvalido Date 2016-06-29 Time 15:51 Sent To  
Notes
2016-06-29 15:56:48CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 (1) PROVIDE MECHANICAL PLANS. SHOW ALL EXISTING AND NEW
 WORK.
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2016-06-27 Cont ID  
Sent By skennedy Date 2016-06-27 Time 16:18 Rev Time 0.00
Received By skennedy Date 2016-06-27 Time 16:18 Sent To  
Notes
2016-06-27 16:19:20NO MECHANICAL SHOWN

Review Stop P PLUMBING
Rev No 2 Status N Date 2016-06-30 Cont ID  
Sent By cthroop Date 2016-06-30 Time 09:37 Rev Time 0.00
Received By cthroop Date 2016-06-30 Time 09:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-06-28 Cont ID  
Sent By skennedy Date 2016-06-28 Time 14:26 Rev Time 0.00
Received By gjohnson Date 2016-06-27 Time 16:18 Sent To  
Notes
2016-06-28 14:40:521ST REVIEW
  
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
  
 PLUMBING COMMENTS:
  
  
 1. PLANS ARE UNCLEAR ON WHAT PLUMBING IS BEING DONE
 PLEASE CLARIFY SCOPE OF PLUMBING WORK.
 PROVIDE A PLAN THAT COMPLY S WITH WPB AMEND TO FBC SEC.
 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS
 SHALL BE DRAWN TO A MINIMUM 1/8 INCH
 SCALE UPON SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE
 MEDIUM. THE BUILDING OFFICIAL MAY
 ESTABLISH THROUGH DEPARTMENTAL POLICY, OTHER STANDARDS
 FOR PLANS AND SPECIFICATIONS, IN
 ORDER TO PROVIDE CONFORMITY TO ITS RECORD RETENTION
 PROGRAM. THIS POLICY MAY INCLUDE SUCH
 THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR
 OTHER ITEMS RELATED TO RECORDS
 MANAGEMENT. ELECTRONIC MEDIA MUST BE COMPATIBLE WITH
 THE ARCHIVE REQUIREMENTS OF
 FLORIDA STATUTES.
  
 2. PROVIDE PLUMBING RISER DIAGRAM. PER WPB AMEND TO FBC
 SEC. 107.3.5.3(11)
  
 DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND
 THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON
 RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.

Review Stop Z ZONING
Rev No 1 Status P Date 2016-06-27 Cont ID  
Sent By skennedy Date 2016-06-27 Time 16:18 Rev Time 0.00
Received By fmittner Date 2016-06-27 Time 13:41 Sent To  
Notes
***NONE***