Review Stop G GAS REVIEW
Rev No 2 Status P Date 2016-06-21 Cont ID  
Sent By tklarge Date 2016-06-21 Time 08:46 Rev Time 0.00
Received By tklarge Date 2016-06-21 Time 06:35 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2016-06-08 Cont ID  
Sent By tklarge Date 2016-06-08 Time 06:26 Rev Time 0.00
Received By tklarge Date 2016-06-08 Time 05:29 Sent To  
Notes
2016-06-08 06:19:451) SHT.P300 - CLARIFY THE TOTAL BTU LOAD FOR THE GAS
 SYSTEM. WHAT IS 115E0? I CALCULATE 1,118,000 BTU'S.
 PLACE THIS ON THE PLANS.
 2) THE GAS PLAN REFERENCES TABLE 402.1 (1 ) OF THE FUEL
 GAS CODE. THERE IS NO SUCH TABLE IN THE GAS CODE. PLACE
 THE CORRECT TABLE NUMBER ON THE PLANS.
 3) SHOW THE CORRESPONDING EHD NUMBER OF THE CORRUGATED
 STAINLESS STEEL TUBING NEXT TO THE TUBING SIZE ON THE
 PLANS FOR EACH PIPE SIZE SHOWN. WPB AMENDMENTS TO FBC
 SEC.107.2.1.
 4) THE PLAN SHOWS A 1 INCH GALVANIZED LINE SUPPLYING 2
 TANKLESS WATER HEATERS AND THE POOL HEATER. THIS LINE
 IS SEVERELY UNDERSIZED IF THIS IS LESS THAN A 2 PSI
 SYSTEM. SUBMIT THE NUMBER OF THE CORRECT SIZING TABLE
 AND PSI OF THE SYSTEM FOR THE GALVANIZED PIPE.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-06-21 Cont ID  
Sent By tklarge Date 2016-06-21 Time 08:46 Rev Time 0.00
Received By tklarge Date 2016-06-17 Time 10:18 Sent To  
Notes
2016-06-20 10:19:13RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-06-08 Cont ID  
Sent By tklarge Date 2016-06-08 Time 06:26 Rev Time 0.00
Received By tklarge Date 2016-06-07 Time 16:32 Sent To  
Notes
2016-06-07 16:33:31TKLARGE'S DESK