| Plan Review Stops For Permit 16060202 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-08-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-08-05 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-08-05 |
Time |
17:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-06-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-06-22 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-06-22 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2016-06-22 11:01:18 | BUILDING PLAN REVIEW | | | W. P. B. REVISION: 16060202 | | | W. P. B. PERMIT: 16020738 | | | ADD: 501 VILLAGE BLVD. | | | CONT: MDS BUILDERS | | | TEL: 561-241-8990 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. JUNE 22/2016 | | | ACTION: DENIED | | | | | | 1) SHEET 015_A2.51 DOES NOT HAVE AN ELECTRONIC | | | SIGNATURE. 61G15-23.005 PROCEDURES FOR SIGNING AND | | | SEALING ELECTRONICALLY TRANSMITTED PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS (ELECTRONIC | | | SEALS). | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2016-09-12 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-09-12 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-09-12 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2016-09-12 16:40:24 | ALL PREVIOUSLY MENTIONED COMMENTS HAVE BEEN | | | SATISFACTORILY ADDRESSED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2016-09-07 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-09-07 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-08-30 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2016-08-30 14:59:38 | WITH REGARDS TO THE RESPONSE TO MY COMMENTS, I SPOKE | | | WITH GORDON SCOTT. HE CLAIMS THAT THE JOB IS IN THE | | | FINAL STAGES OF COMPLETION AND I DO NOT SEE RECORD OF | | | ANY ELECTRICAL INSPECTIONS. HE WILL RESEARCH THIS | | | FURTHER AND GET BACK TO ME. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2016-08-02 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-08-02 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-08-02 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2016-08-02 12:10:23 | ELECTRICAL REVIEW NOTES | | | REVIEWED FOR COMPLIANCE WITH: | | | 5TH EDITION FBC 2014 & NFPA 70 2011 (NEC) | | | | | | JOB NAME: | | | JOB ADDRESS: 501 VILLAGE BLVD. | | | DESCRIPTION: TENANT IMPROVEMENT | | | MAST. PERMIT:16020738 | | | REVISION: 16070202 | | | | | | WHILE CONDUCTING THE REVIEW OF THIS REVISION I NOTED | | | THAT IN ADDITION TO THE PREVIOUSLY MENTIONED FBC-E | | | LIGHTING CONTROL REQUIREMENTS, I MAY HAVE OVERLOOKED | | | THE DAYLIGHT ZONE LIGHTING CONTROLS AND THUS ADDRESS | | | THAT HERE. | | | SHEET E2.1 | | | 1. OFFICES 121, 151, 152, 153, ARE MISSING DAYLIGHT | | | ZONE CONTROL PER FBC-E405.2.0.3 | | | 2. CONFERENCE ROOMS 124, 125, 126, 154, ARE MISSING | | | DAYLIGHT ZONE CONTROL AS PER FBC-E405.2.2.3 | | | 3. VESTIBULE 100 IS MISSING DAYLIGHT ZONE CONTROL AS | | | PER FBC-E405.2.2.3 | | | 4. I CAN?T DETERMINE FROM THE FLOOR PLAN IF THE MAIN | | | WORK AREA 102 WILL HAVE WHAT IS CONSIDERED DAYLIGHT | | | ZONE, BUT IF SO, IT TOO WILL NEED DAYLIGHT ZONE CONTROL | | | AS INDICATED ABOVE. | | | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | | GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-06-29 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-06-29 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-06-28 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2016-06-29 09:24:49 | 1ST ELECTRICAL REVIEW NOTES | | | REVIEWED FOR COMPLIANCE WITH: | | | 5TH EDITION FBC 2014 & NFPA 70 2011 (NEC) | | | | | | 1. SHEET E0.1 UPLOADED TO DRAWINGS FOLDER DOES NOT | | | MATCH NARRATIVE. CONDUIT SIZES APPEAR AS ON THE | | | APPROVED PLANS. (FILENET) (NOTE: THERE IS A SHEET E0.1 | | | UPLOADED TO THE SUPPORTING DOCUMENTS FILE WITH ALL THE | | | CORRECTIONS TO MATCH THE NARRATIVE, BUT IT IS NOT | | | SIGNED). CORRECT AS INDICATED. | | | 2. ELIMINATE ALL THE UNNECESSARY CLOUDING FROM SHEETS | | | AND LEAVE ONLY THAT WHICH PERTAINS TO THE NARRATIVE. | | | ALL PRIOR CLOUDING SHOULD BE ON THE CURRENT APPROVED | | | SET OF PLANS. MAKE INDICATION ON THE NARRATIVE AS TO | | | WHICH REVISION ADDRESSES THE CHANGES AS NOT ALL | | | REVISIONS WERE MADE ON THE SAME DATE ON ALL RESPECTIVE | | | SHEETS. | | | 3. SHEET E3.2 HAS THE ADDITION OF A CAMERA NOT | | | ADDRESSED ON THE NARRATIVE IN ADDITION TO THE WORK | | | MENTIONED FOR THE IT ROOM. CORRECT ACCORDINGLY. | | | 4. INDICATE COMPLIANCE WITH NEC 760.41(B) FOR CIRCUITS | | | 20 & 22 OF PANEL THE FIRE ALARM BREAKERS IN PANEL ?L1B? | | | AT A MINIMUM WITH A NOTE ON THE PLANS. | | | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | | GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2016-06-24 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2016-06-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-06-20 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2016-06-24 12:00:07 | | | | | | | | | | | | | 1) SHEET A 250 - THERE IS AN INCORRECT REFERENCE TO THE | | | FIRE CODE. | | | | | | FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 72, 2010 EDITION. | | | | | | FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 10, 2010 EDITION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2016-09-13 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-09-13 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-09-12 |
Time |
16:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-09-09 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2016-09-09 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2016-08-10 |
Time |
14:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-08-05 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2016-08-05 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2016-07-27 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-07-05 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2016-07-05 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2016-06-16 |
Time |
07:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2016-09-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-09-13 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-09-13 |
Time |
09:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2016-08-04 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-08-04 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-08-04 |
Time |
10:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2016-06-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-06-23 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-06-23 |
Time |
16:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-06-23 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-06-23 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-06-23 |
Time |
16:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2016-09-13 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-09-13 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-09-13 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2016-09-13 09:19:17 | SIGNATURES VERIFIED ON THE MECHANICAL SHEETS. | | 2016-09-12 16:41:37 | SIGNATURES VERIFIED ON THE ELECTRICAL SHEETS. |
|
|