Plan Review Details - Permit 16060125
Plan Review Stops For Permit 16060125
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-09-21 Cont ID  
Sent By jwitmer Date 2016-09-21 Time 15:38 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-06-22 Cont ID  
Sent By jwitmer Date 2016-06-22 Time   Rev Time 0.00
Received By jwitmer Date 2016-06-22 Time 10:24 Sent To  
Notes
2016-06-22 10:27:53BUILDING PLAN REVIEW
 W. P. B. REVISION: 16060125
 W. P. B. PERMIT: 15060530 BLOWER BUILDING
 ADD: 4395 EASLEY ST.
 CONT: POOLE KENT.
 TEL: (561)997-8070 NO NEW TEL.
 E-MAIL:[email protected] NO NEW E-MAIL
 ADDRESS
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 1ST REVIEW
 DATE: WED. JUNE 22/ 2016
 ACTION: DENIED
  
 1) CALCULATIONS FOR PRESTRESS HOLLOW CODE PLANK &
 DOUBLE TEE DESIGN BY P. E. JONN MCGREW SUBMITTED
 ELECTRONICALLY DO NOT HAVE AN ELECTRONIC SIGNATURE.
 PLEASE NOTE IF PAPER CALCULATIONS WILL NEED TO BE
 SUBMITTED THEY MUST BE IN COMPLIANCE WITH:
 FL. ADMIN. S. 61G15-23.002(2) FL. ADMIN. CODE. A COVER
 SHEET OR INDEX SHEET FOR ENGINEERING SPECIFICATIONS MAY
 BE USED AND THAT SHEET MUST BE SIGNED IN RESPONSIBLE
 CHARGE OF THE PRODUCTION & PREPARATION OF EACH SECTION
 OF THE ENGINEERING SPECIFICATION WITH SUFFICIENT
 INFORMATION ON THE COVER SHEET OR INDEX LISTING HOW
 MANY PAGES ARE COVERED UNDER THE COVER SHEET OR INDEX
 SHEET.
 OR INCOMPLIANCE WITH:
 FL. ADMIN. S. 61G15-23.005 PROCEDURES FOR SIGNING AND
 SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. (2) A
 PROFESSIONAL ENGINEER UTILIZING A DIGITAL SIGNATURE TO
 SEAL ENGINEERING WORK SHALL HAVE THEIR IDENTITY
 AUTHENTICATED BY A CERTIFICATION AUTHORITY AND SHALL
 ASSURE THAT THE DIGITAL SIGNATURE IS:
 (A) UNIQUE TO THE PERSON USING IT;
 (B) CAPABLE OF VERIFICATION;
 (C) UNDER THE SOLE CONTROL OF THE PERSON USING IT;
 (D) LINKED TO A DOCUMENT IN SUCH A MANNER THAT THE
 ELECTRONIC SIGNATURE IS INVALIDATED IF ANY DATA IN
 THE DOCUMENT ARE CHANGED.
  
 2) THE PRESTRESS HOLLOW CODE PLANK & DOUBLE TEE DESIGN
 BY P. E. JONN MCGREW A DELEGATE ENGINEER SHALL FORWARD
 THE DELEGATED ENGINEERING DOCUMENTS TO THE ENGINEER OF
 RECORD FOR REVIEW. FL. S.
 61G-15-30.006 (3).
  
 3) THE PLANS SUBMITTED FOR PRESTRESS HOLLOW CODE PLANK
 & DOUBLE TEE DESIGN ARE NOT SIGNED NOR SEALED THEY ALSO
 STATE THE PLANS ARE PRELINARY BUT NOT REVIEWED BY
 NEITHER THE STRUCTURAL ENGINEER OR THE ARCHITECT.
  
 FL ADMIN CODE 61G15-23.002 ENGINEERS EFFECTIVE DATE
 05/06/2009. (2)(A) EVERY SHEET OF PLANS AND PRINTS
 WHICH MUST BE SEALED UNDER THE PROVISIONS OF CHAPTER
 471, F.S., SHALL BE SEALED, SIGNED AND DATED BY THE
 PROFESSIONAL ENGINEER IN RESPONSIBLE CHARGE.
  
 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING
 ELECTRONICALLY TRANSMITTED PLANS, SPECIFICATIONS,
 REPORTS OR OTHER DOCUMENTS (ELECTRONIC SEALS).
 (3) (3) THE AFFIXING OF AN ELECTRONIC SIGNATURE TO
 ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR OTHER
 DOCUMENTS AS PROVIDED HEREIN SHALL CONSTITUTE THE
 SIGNING AND SEALING OF SUCH ITEMS.
 (A) A DIGITALLY CREATED SEAL AS SET FORTH IN RULE
 61G15-23.002, F.A.C. MAY BE PLACED WHERE IT WOULD
 APPEAR IF THE ITEM WERE BEING PHYSICALLY SIGNED, DATED
 AND SEALED.
 (B) THE DATE THAT THE ELECTRONIC SIGNATURE IS TO BE
 PLACED INTO THE DOCUMENT MUST APPEAR ON THE DOCUMENT IN
 ACCORDANCE WITH SUBSECTION 61G15-23.001(5), F.A.C. AND
 WHERE IT WOULD APPEAR IF THE ITEM WERE BEING PHYSICALLY
 SIGNED, DATED AND SEALED.
 (C) A SCANNED, FACSIMILE, DIGITALLY CREATED OR COPIED
 IMAGE OF THE LICENSEE?S SIGNATURE SHALL NOT BE USED ON
 ELECTRONICALLY SIGNED AND SEALED ENGINEERING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
 (D) THE ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR
 OTHER DOCUMENTS BEING ELECTRONICALLY SIGNED AND SEALED
 SHALL INCLUDE TEXT TO INDICATE THE FOLLOWING AND PLACE
 IT WHERE AN ORIGINAL SIGNATURE WOULD APPEAR IF THE ITEM
 WERE BEING PHYSICALLY SIGNED, DATED AND SEALED:
 1. THE SAME INFORMATION REQUIRED BY SUBSECTION
 61G15-23.002(2), F.A.C. IF A DIGITALLY CREATED SEAL IS
 NOT USED,
 2. THE ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED
 USING A SHA-1 AUTHENTICATION CODES; AND,
 3. PRINTED COPIES OF THE DOCUMENT ARE NOT CONSIDERED
 SIGNED AND SEALED AND ALL SHA-1 AUTHENTICATION CODE
 MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
 (E) FORMATTING OF SEALS AND TEXT SIMILAR TO THAT
 DEPICTED BELOW MAY BE USED.
 1. WHEN A DIGITALLY CREATED SEAL IS USED:
  
 THE DELEGATE ENGINEER SHALL FORWARD THE DELEGATED
 ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR
 REVIEW. FL. S. 61G-15-30.006 (3).
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC...
  
  
  
  
  
2016-06-22 10:24:32 
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-09-15 Cont ID  
Sent By   Date 2016-09-15 Time   Rev Time 0.00
Received By cpuell Date 2016-09-15 Time 14:43 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-07-05 Cont ID  
Sent By lmarchan Date 2016-07-05 Time 14:44 Rev Time 0.00
Received By lmarchan Date 2016-06-17 Time 10:07 Sent To  
Notes
***NONE***