Plan Review Details - Permit 16060079
Plan Review Stops For Permit 16060079
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-09-07 Cont ID  
Sent By cthroop Date 2016-09-07 Time 13:33 Rev Time 0.00
Received By cthroop Date 2016-09-07 Time 13:01 Sent To  
Notes
2016-09-07 13:34:33WINDOWS ON SEPERATE PERMIT - 16050105

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-07-26 Cont ID  
Sent By cthroop Date 2016-07-15 Time 09:23 Rev Time 0.00
Received By cthroop Date 2016-07-15 Time 09:23 Sent To  
Notes
2016-07-15 09:32:35SEPERATE WINDOW PERMIT ON-FILE - 16050105
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-09-07 Cont ID  
Sent By mvaldes Date 2016-09-07 Time 13:51 Rev Time 0.00
Received By mvaldes Date 2016-09-07 Time 13:51 Sent To M
Notes
2016-09-07 13:57:56REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
 PASSED WITH THE FOLLOWING PROVISO
  
 1] A SWITCHED CONTROLLED LIGHTING OUTLET SHALL BE
 INSTALLED IN THE ATTIC ENTRANCE NEAR THE VICINITY OF
 ANY SERVICING EQUIPMENT IF PRESENT. NEC 210.70(3)

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-06-06 Cont ID  
Sent By mvaldes Date 2016-06-06 Time 18:39 Rev Time 0.00
Received By mvaldes Date 2016-06-06 Time 18:14 Sent To  
Notes
2016-06-06 18:40:04JOB PERMIT NUMBER: 16060079
 JOB ADDRESS: 2601 TECUMSEH DR
 WEST PALM BEACH FLORIDA
 DATE: JUNE 6 2016
  ELECTRICAL PLAN REVIEW COMMENTS
 THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION
 HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF
 THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC,
 (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST
 PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF
 SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED.
  
 - EXISTING BEDROOM # 2 IS MISSING A SMOKE ALARM
 FBC-R314.3(LOCATION) ?OUTSIDE AREAS DIRECTLY OUTSIDE
 THE VICINITY OF A BEDROOM MIGHT REQUIRE CARBON MONOXIDE
 DETECTORS IF A GAS APPLIANCE IS AVAILABLE, FIREPLACE
 WITHIN THE DWELLING UNIT, OR AN ATTACHED GARAGE IS
 PRESENT. THE COMBO ALARM SHALL BE WITHIN 10? OF ECH
 SLEEPING ROOM. PLEASE VERIFY ? FBC-R315.1
 - NEC 406.11 TAMPER-RESISTANT RECEPTACLES IN DWELLING
 UNITS. IN ALL AREAS SPECIFIED IN 210.52, ALL 125-VOLT,
 15 AND 20 AMPERE RECEPTACLES SHALL BE LISTED TAMPER
 RESISTANT RECEPTACLES.
 - FBC-E R402.4.8 RECESSED LIGHTING. RECESSED LIGHTING
 INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE IC
 RATED AND BE SEALED TO LIMIT AIR LEAKAGE BETWEEN
 CONDITIONED & UNCONDITIONED SPACES.
  
 PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE
 MENTIONED DEFICIENCIES.
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE
 LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE
 STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD
 INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE
 OR ACTION TO SAME. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE
 PREVIOUSLY REVIEWED SHEETS FOR COMPARISON.
 CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 FBC 2014 5TH ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-09-14 Cont ID  
Sent By lmarchan Date 2016-09-14 Time 09:14 Rev Time 0.00
Received By lmarchan Date 2016-09-12 Time 12:20 Sent To  
Notes
2016-09-12 12:20:20ROUTED TO JORGE VALIDO

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-09-08 Cont ID  
Sent By cpuell Date 2016-09-08 Time 09:36 Rev Time 0.00
Received By cpuell Date 2016-08-24 Time 11:02 Sent To  
Notes
2016-08-25 11:02:42R27

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-07-27 Cont ID  
Sent By cpuell Date 2016-07-27 Time 09:26 Rev Time 0.00
Received By cpuell Date 2016-06-02 Time 13:39 Sent To  
Notes
2016-06-02 13:39:21R08

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2016-09-07 Cont ID  
Sent By cthroop Date 2016-09-07 Time 13:33 Rev Time 0.00
Received By cthroop Date 2016-09-07 Time 13:33 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-07-15 Cont ID  
Sent By cthroop Date 2016-07-15 Time 09:33 Rev Time 0.00
Received By cthroop Date 2016-07-15 Time 09:33 Sent To  
Notes
2016-07-15 09:34:14BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 ACTION: DENIED
 DATE: 7/15/16
  
 1. STATE EXISTING SQ. FOOTAGE AND ADDITIONAL SQ.
 FOOTIAGE ON PLANS.
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2016-09-13 Cont ID  
Sent By jvalido Date 2016-09-13 Time 18:37 Rev Time 0.00
Received By jvalido Date 2016-09-13 Time 18:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-09-07 Cont ID  
Sent By jvalido Date 2016-09-07 Time 17:30 Rev Time 0.00
Received By jvalido Date 2016-09-07 Time 16:59 Sent To  
Notes
2016-09-07 17:16:17CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
  
 (1) PROVIDE CORRECT TOTAL CFM VALUES FOR A/C SYSTEM #1.
 AS PER PLANS EQUIPMENT SCHEDULE AND FBC ENERGY/HEAT
 LOAD CALCULATIONS SYSTEM #1 AHU PROVIDES A TOTAL OF
 2000 CFM. AS PER THE PLANS NOTED SUPPLY OUTLET CFM, AHU
 #1 TOTAL CFM IS 2450. THIS DOES NOT MATCH THE SUBMITTED
 DOCUMENTS.
  
 (2) PROVIDE CORRECT TOTAL CFM VALUES FOR A/C SYSTEM #2.
 AS PER PLANS EQUIPMENT SCHEDULE AND FBC ENERGY/HEAT
 LOAD CALCULATIONS SYSTEM #1 AHU PROVIDES A TOTAL OF
 1400 CFM. AS PER THE PLANS NOTED SUPPLY OUTLET CFM, AHU
 #1 TOTAL CFM IS1100. THIS DOES NOT MATCH THE SUBMITTED
 DOCUMENTS.
  
 PROVIDE A BALANCED CFM AMOUNT FOR BOTH A/C SYSTEMS #1
 AND #2.
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2016-07-26 Time   Rev Time 0.00
Received By jvalido Date 2016-07-26 Time 16:23 Sent To  
Notes
2016-07-26 16:25:33CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA
 BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION
  
 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1
 INFORMATION ON CONSTRUCTION DOCUMENTS
  
 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS
 SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON
 SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM.
 THE BUILDING OFFICIAL MAY ESTABLISH THROUGH
 DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS AND
 SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS
 RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH
 THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR
 OTHER ITEMS RELATED TO RECORDS MANAGEMENT. ELECTRONIC
 MEDIA MUST BE COMPATIBLE WITH THE ARCHIVE REQUIREMENTS
 OF FLORIDA STATUTES.
  
 (1) PROVIDE TWO SETS OF PLANS.
 (2) PROVIDE AN EQUIPMENT SCHEDULE WITH ALL HVAC
 EQUIPMENT.
 (3) PROVIDE ALL SUPPLY AND RETURN GRILL SIZES.
 (4) PROVIDE CFM VALUES FOR ALL SUPPLY DROPS.
 (5) PROVIDE ALL SUPPLY DUCT SIZES.
 (6) PROVIDE CONDENSER TIE DOWN SCHEDULE FOR ALL
 EQUIPMENT.
  
 FLORIDA ENERGY CODE FBC 2014
  
 (7) PROVIDE HEAT LOAD ASPER MANUAL D AND J.
 (8) PROVIDE ENERGY CALCULATIONS FORM R405-2014.
 (9) PROVIDE AHRI.
  
 JORGE VALIDO
 WPB MECHANICAL INSPECTOR/PLANS EXAMINER
 [email protected]
 561-805-6716
  
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2016-07-26 Cont ID  
Sent By cthroop Date 2016-07-15 Time 09:34 Rev Time 0.00
Received By cthroop Date 2016-07-15 Time 09:34 Sent To  
Notes
2016-07-15 09:35:40SEPERATE ROOFING PERMIT ON-FILE - 16050756
  
  