| Plan Review Stops For Permit 16060079 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-09-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-09-07 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-09-07 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2016-09-07 13:34:33 | WINDOWS ON SEPERATE PERMIT - 16050105 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-07-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-07-15 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-07-15 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2016-07-15 09:32:35 | SEPERATE WINDOW PERMIT ON-FILE - 16050105 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-09-07 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-09-07 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-09-07 |
Time |
13:51 |
Sent To |
M |
|
| Notes |
| 2016-09-07 13:57:56 | REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | PASSED WITH THE FOLLOWING PROVISO | | | | | | 1] A SWITCHED CONTROLLED LIGHTING OUTLET SHALL BE | | | INSTALLED IN THE ATTIC ENTRANCE NEAR THE VICINITY OF | | | ANY SERVICING EQUIPMENT IF PRESENT. NEC 210.70(3) |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-06-06 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-06-06 |
Time |
18:39 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-06-06 |
Time |
18:14 |
Sent To |
|
|
| Notes |
| 2016-06-06 18:40:04 | JOB PERMIT NUMBER: 16060079 | | | JOB ADDRESS: 2601 TECUMSEH DR | | | WEST PALM BEACH FLORIDA | | | DATE: JUNE 6 2016 | | | ELECTRICAL PLAN REVIEW COMMENTS | | | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF | | | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, | | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | | | | - EXISTING BEDROOM # 2 IS MISSING A SMOKE ALARM | | | FBC-R314.3(LOCATION) ?OUTSIDE AREAS DIRECTLY OUTSIDE | | | THE VICINITY OF A BEDROOM MIGHT REQUIRE CARBON MONOXIDE | | | DETECTORS IF A GAS APPLIANCE IS AVAILABLE, FIREPLACE | | | WITHIN THE DWELLING UNIT, OR AN ATTACHED GARAGE IS | | | PRESENT. THE COMBO ALARM SHALL BE WITHIN 10? OF ECH | | | SLEEPING ROOM. PLEASE VERIFY ? FBC-R315.1 | | | - NEC 406.11 TAMPER-RESISTANT RECEPTACLES IN DWELLING | | | UNITS. IN ALL AREAS SPECIFIED IN 210.52, ALL 125-VOLT, | | | 15 AND 20 AMPERE RECEPTACLES SHALL BE LISTED TAMPER | | | RESISTANT RECEPTACLES. | | | - FBC-E R402.4.8 RECESSED LIGHTING. RECESSED LIGHTING | | | INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE IC | | | RATED AND BE SEALED TO LIMIT AIR LEAKAGE BETWEEN | | | CONDITIONED & UNCONDITIONED SPACES. | | | | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | | MENTIONED DEFICIENCIES. | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | | STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD | | | INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE | | | OR ACTION TO SAME. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS FOR COMPARISON. | | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | FBC 2014 5TH ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-09-14 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2016-09-14 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2016-09-12 |
Time |
12:20 |
Sent To |
|
|
| Notes |
| 2016-09-12 12:20:20 | ROUTED TO JORGE VALIDO |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-09-08 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-09-08 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-08-24 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-07-27 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-07-27 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-06-02 |
Time |
13:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2016-09-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-09-07 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-09-07 |
Time |
13:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2016-07-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-07-15 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-07-15 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2016-07-15 09:34:14 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER ? PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | DATE: 7/15/16 | | | | | | 1. STATE EXISTING SQ. FOOTAGE AND ADDITIONAL SQ. | | | FOOTIAGE ON PLANS. | | | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2016-09-13 |
|
|
Cont ID |
|
| Sent By |
jvalido |
Date |
2016-09-13 |
Time |
18:37 |
Rev Time |
0.00 |
| Received By |
jvalido |
Date |
2016-09-13 |
Time |
18:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-09-07 |
|
|
Cont ID |
|
| Sent By |
jvalido |
Date |
2016-09-07 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
jvalido |
Date |
2016-09-07 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2016-09-07 17:16:17 | CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA | | | BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION | | | | | | 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS | | | | | | | | | (1) PROVIDE CORRECT TOTAL CFM VALUES FOR A/C SYSTEM #1. | | | AS PER PLANS EQUIPMENT SCHEDULE AND FBC ENERGY/HEAT | | | LOAD CALCULATIONS SYSTEM #1 AHU PROVIDES A TOTAL OF | | | 2000 CFM. AS PER THE PLANS NOTED SUPPLY OUTLET CFM, AHU | | | #1 TOTAL CFM IS 2450. THIS DOES NOT MATCH THE SUBMITTED | | | DOCUMENTS. | | | | | | (2) PROVIDE CORRECT TOTAL CFM VALUES FOR A/C SYSTEM #2. | | | AS PER PLANS EQUIPMENT SCHEDULE AND FBC ENERGY/HEAT | | | LOAD CALCULATIONS SYSTEM #1 AHU PROVIDES A TOTAL OF | | | 1400 CFM. AS PER THE PLANS NOTED SUPPLY OUTLET CFM, AHU | | | #1 TOTAL CFM IS1100. THIS DOES NOT MATCH THE SUBMITTED | | | DOCUMENTS. | | | | | | PROVIDE A BALANCED CFM AMOUNT FOR BOTH A/C SYSTEMS #1 | | | AND #2. | | | | | | JORGE VALIDO | | | WPB MECHANICAL INSPECTOR/PLANS EXAMINER | | | [email protected] | | | 561-805-6716 | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2016-07-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
jvalido |
Date |
2016-07-26 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2016-07-26 16:25:33 | CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA | | | BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION | | | | | | 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS | | | | | | 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS | | | SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | | THE BUILDING OFFICIAL MAY ESTABLISH THROUGH | | | DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS AND | | | SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS | | | RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH | | | THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR | | | OTHER ITEMS RELATED TO RECORDS MANAGEMENT. ELECTRONIC | | | MEDIA MUST BE COMPATIBLE WITH THE ARCHIVE REQUIREMENTS | | | OF FLORIDA STATUTES. | | | | | | (1) PROVIDE TWO SETS OF PLANS. | | | (2) PROVIDE AN EQUIPMENT SCHEDULE WITH ALL HVAC | | | EQUIPMENT. | | | (3) PROVIDE ALL SUPPLY AND RETURN GRILL SIZES. | | | (4) PROVIDE CFM VALUES FOR ALL SUPPLY DROPS. | | | (5) PROVIDE ALL SUPPLY DUCT SIZES. | | | (6) PROVIDE CONDENSER TIE DOWN SCHEDULE FOR ALL | | | EQUIPMENT. | | | | | | FLORIDA ENERGY CODE FBC 2014 | | | | | | (7) PROVIDE HEAT LOAD ASPER MANUAL D AND J. | | | (8) PROVIDE ENERGY CALCULATIONS FORM R405-2014. | | | (9) PROVIDE AHRI. | | | | | | JORGE VALIDO | | | WPB MECHANICAL INSPECTOR/PLANS EXAMINER | | | [email protected] | | | 561-805-6716 | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2016-07-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-07-15 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-07-15 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2016-07-15 09:35:40 | SEPERATE ROOFING PERMIT ON-FILE - 16050756 | | | | | | |
|
|