Plan Review Details - Permit 16060021
Plan Review Stops For Permit 16060021
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-09-13 Cont ID  
Sent By jwitmer Date 2016-09-13 Time 11:36 Rev Time 0.00
Received By jwitmer Date 2016-09-13 Time 11:09 Sent To  
Notes
2016-09-13 11:09:47BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16060021
 ADD: 513 SAPODILLA
 CONT: NUJAK CONSTRUCTION
 TEL: 561-320-2566
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 5TH REVIEW
 DATE: TUES. SEPT. 09/13/2016
 ACTION: BUILDING PROVISO
  
 HISTORIC 2 STORY R-3 SINGLE FAMILY RESIDENCE
  
 1) BUILDING PROVISO: DEFERRED SUBMITTAL: 2014 FBC-B
 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1
 COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY
 AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF
 PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE
 PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES
 (E) SHUTTERS
 (F) SKYLIGHTS
 (G) PRE-ENGINEERED A/C STANDS
 FOR ALL PRODUCTS WITH GLAZING, PLEASE IDENTIFY THE
 OPENING WIDTH & HEIGHT, TYPE OF GLAZING, MULLION
 INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE
 PRESSURES FOR EACH OPENING SIZE.
  
 DEFERRED SUBMITTAL 107.3.4.1 THOSE PRODUCTS WHICH ARE
 REGULATED BY DCA RULE 9N-3 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-08-23 Cont ID  
Sent By jwitmer Date 2016-08-23 Time 13:45 Rev Time  
Received By jwitmer Date 2016-08-23 Time 11:25 Sent To  
Notes
2016-08-23 13:42:06 
 BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16060021
 ADD: 513 SAPODILLA
 CONT: NUJAK CONSTRUCTION
 TEL: 561-320-2566
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 4TH REVIEW
 DATE: TUES. AUG. 23/ 2016
 ACTION:
  
 HISTORIC 2 STORY R-3 SINGLE FAMILY RESIDENCE
  
 1) 4TH REVIEW/ REQUEST. PLEASE NOTE THE MINIMUM WINDOW
 SIZE FOR A SINGLE HUNG WINDOW IS:
 1ST FLOOR 37X59 5.33 SQ. FT.
 2ND FLOOR 37X63 5.78 SQ. FT.
 AT LEAST ONE WINDOW IN EACH BEDROOM SHALL COMPLY WITH:
 2014 FBC-B 1029.2 MINIMUM SIZE. EMERGENCY ESCAPE AND
 RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING
 OF 5.7 SQUARE FEET (0.53 M2).
 EXCEPTION: THE MINIMUM NET CLEAR OPENING FOR GRADE
 FLOOR EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE 5
 SQUARE FEET (0.46 M2).
  
 FBC-B 1029.2.1 MINIMUM DIMENSIONS. THE MINIMUM NET
 CLEAR OPENING HEIGHT DIMENSION SHALL BE 24 INCHES (610
 MM). THE MINIMUM NET CLEAR OPENING WIDTH DIMENSION
 SHALL BE 20 INCHES (508 MM). THE NET CLEAR OPENING
 DIMENSIONS SHALL BE THE RESULT OF NORMAL OPERATION OF
 THE OPENING.
  
 FBC-B 1029.3 MAXIMUM HEIGHT FROM FLOOR. EMERGENCY
 ESCAPE AND RESCUE OPENINGS SHALL HAVE THE BOTTOM OF THE
 CLEAR OPENING NOT GREATER THAN 44 INCHES (1118 MM)
 MEASURED FROM THE FLOOR.
  
  
 2)BUILDING PROVISO: DEFERRED SUBMITTAL: 2014 FBC-B
 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1
 COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY
 AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF
 PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE
 PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES
 (E) SHUTTERS
 (F) SKYLIGHTS
 (G) PRE-ENGINEERED A/C STANDS
 FOR ALL PRODUCTS WITH GLAZING, PLEASE IDENTIFY THE
 OPENING WIDTH & HEIGHT, TYPE OF GLAZING, MULLION
 INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE
 PRESSURES FOR EACH OPENING SIZE.
  
 DEFERRED SUBMITTAL 107.3.4.1 THOSE PRODUCTS WHICH ARE
 REGULATED BY DCA RULE 9N-3 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-08-04 Cont ID  
Sent By vperez Date 2016-08-04 Time 09:19 Rev Time 0.00
Received By vperez Date 2016-08-04 Time 09:19 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2016-08-26 Cont ID  
Sent By destabro Date 2016-08-26 Time 08:43 Rev Time 0.00
Received By destabro Date 2016-08-26 Time 08:43 Sent To B
Notes
2016-08-26 08:43:528/26/16- APPROVED BY HPD, RETURNED TO BOX C26.DLE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-09-13 Cont ID  
Sent By jwitmer Date 2016-09-13 Time 11:38 Rev Time 0.00
Received By jwitmer Date 2016-09-08 Time 15:41 Sent To  
Notes
2016-09-09 15:42:02RESUB ROUTED TO CCOLE
 *TRAVELLING WITH 16030064*

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-09-08 Cont ID  
Sent By ccole Date 2016-09-08 Time 08:08 Rev Time 0.00
Received By ccole Date 2016-07-29 Time 14:41 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2016-09-13 Cont ID  
Sent By ccole Date 2016-09-13 Time 15:26 Rev Time 0.00
Received By ccole Date 2016-09-13 Time 15:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-09-09 Cont ID  
Sent By ccole Date 2016-09-09 Time 16:47 Rev Time 0.00
Received By ccole Date 2016-09-09 Time 16:47 Sent To  
Notes
2016-09-09 16:52:183RD REVIEW FBC-2014 MECHANICAL
 PERMIT #16060021
 9/9/16
  
 1) THE ARCHITECT OF RECORD HAS PLACED HIS SIGNATURE BUT
 NOT HIS SEAL ON SHEET M1.3- REFER TO SECTION
 61G1-16.003 FAC AND PROVIDE THE SEAL.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-09-08 Cont ID  
Sent By ccole Date 2016-09-08 Time 08:08 Rev Time 0.00
Received By ccole Date 2016-09-08 Time 08:08 Sent To  
Notes
2016-09-08 08:08:374TH REVIEW FBC-2014 MECHANICAL
 PERMIT #16030064
 8/30/16
  
 1) THE MECHANICAL PLANS FOR THE SINGLE FAMIY HOME WERE
 NOT RESUBMITTED. PLEASE PROVIDE THE PLANS.
  
 2) SHEET M2.1: THE ENGINEER'S TITLE BLOCK HAS BEEN
 PLACED ON THE PLAN. IN ACCORDANCE WITH SECTION
 61G1-23.002 FLORIDA ADMINISTRATIVE CODE, THE ENGINEER
 MUST PLACE HIS SIGNATURE AND SEAL ON THE PLAN, OR
 REMOVE THE TITLE BLOCK IF THE ARCHITECT OF RECORD IS
 SIGNING OFF.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-08-23 Cont ID  
Sent By gjohnson Date 2016-08-23 Time 09:48 Rev Time 0.00
Received By gjohnson Date 2016-08-23 Time 09:48 Sent To  
Notes
2016-08-23 09:49:08 
 PROVISO: SEPARATE PERMIT REQUIRED FOR THE BACKFLOWS ON
 FIRE SPRINKLER LINE AND POTABLE WATER METERS FOR
 APARTMENT BUILDING.
 1. THE AMES 3000SS BACK FLOW THAT IS SPACED OUT FOR THE
 FIRE LINE DOES NOT MEET THE LEAD FREE REQUIREMENTS PER
 THE UNIVERSITY OF SOUTHERN CALIFORNIA?S ( USC ) LIST OF
 APPROVED DEVICES.
  
 DOCUMENTATION REQUIRED FOR BACKFLOW PREVENTION DEVICE
 PERMITS
  
 EFFECTIVE DATE: JANUARY 4TH, 2016
  
 THE PERMIT APPLICATION SHALL BE SUBMITTED WITH THE
 FOLLOWING DOCUMENTATION:
  
 1) TWO COPIES OF THE MANUFACTURER?S SPECIFICATIONS FOR
 THE BACKFLOW PREVENTER. THE MAKE, MODEL AND SIZE OF THE
 DEVICE SHALL BE NOTED IN THE DESCRIPTION OF WORK
 SECTION ON THE PERMIT APPLICATION.
  
 2) ALL BACKFLOW DEVICES MUST BE LEAD FREE.
  
 3) ALL BACKFLOW DEVICES MUST BE ON THE UNIVERSITY OF
 SOUTHERN CALIFORNIA?S ( USC ) LIST OF APPROVED DEVICES.
 4) CONTACT FIELD CUSTOMER SERVICE AT 561-822-2240 TO
 CONFIRM IF THE DEVICE YOU ARE PURCHASING MEETS THE
 CITY?S REQUIREMENTS.
 5) BACKFLOW PREVENTION DEVICES SHALL BE LOCATED
 IMMEDIATELY AFTER THE METER AND MUST BE TESTED AND
 CERTIFIED BY THE CITY OF WEST PALM BEACH UTILITIES
 DEPARTMENT. PLEASE CONTACT THE CITY OF WEST PALM BEACH
 PUBLIC UTILITIES CENTRAL OPERATIONS AT 561-822-2210 TO
 ARRANGE FOR THE UTILITIES DEPARTMENT TO CERTIFY THE
 DEVICE.
 NOTE: THE PERMIT CARD AND MANUFACTURER?S SPECIFICATIONS
 SHALL BE ON THE JOBSITE FOR INSPECTION.
 PLEASE REFER TO THE ATTACHED DOCUMENT FOR INFORMATION
 REGARDING THE CITY OF WEST PALM BEACH APPROVED
 CONTRACTOR?S LIST FOR CERTIFYING / RECERTIFYING
 BACKFLOW DEVICES.
 THE ESTIMATED REVIEW TIME FOR THESE PERMITS IS
 APPROXIMATELY 72 HOURS.
 THE CITY OF WEST PALM BEACH CROSS CONNECTION CONTROL
 MANUAL CAN BE FOUND AT :
 HTTP://WPB.ORG/UTILITIES/BACKFLOW
 UNIVERSITY OF SOUTHERN CALIFORNIA WEBSITE ADDRESS:
 WWW.USC.EDU/DEPT/FCCCHR
 QUESTIONS REGARDING PERMITTING REQUIREMENTS MAY BE
 DIRECTED TO:
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2016-08-22 Cont ID  
Sent By   Date 2016-08-22 Time   Rev Time 0.00
Received By kmartin Date 2016-08-19 Time 09:50 Sent To  
Notes
2016-08-22 09:11:30PROVISO
 PERMIT DOES NOT INCLUDE PARKING IMPROVEMENTS.
  