Plan Review Details - Permit 16051166
| Plan Review Stops For Permit 16051166 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-10-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-10-13 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-10-13 |
Time |
08:47 |
Sent To |
ENG |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-06-13 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-06-13 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-06-13 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2016-06-13 09:51:52 | 1ST REVIEW: FBC 2014 5TH ED | | | | | | DENIED: SHOW ACCURATE INFORMATION PER FBC 107 | | | | | | THE PLAN INDICATES THE BUILDING IS A "RESIDENCE" | | | ALTHOUGH RECORDS INDICATE IT IS A MULTI FAMILY DWELLING | | | CONSISTING OF 3 OR 4 DWELLING UNITS. PLEASE ACCURATELY | | | REFLECT ON THE PLAN THE QUANTITY OF DEWLLING UNITS AND | | | USE OF THE STRUCTURE THE PARKING LOT IS INTENDED TO | | | SERVE. PLEASE ADDITIONALLY INDICATE IF YOU HAVE INTENT | | | TO UPGRADE AS TO ACCESSIBILITY CRITERIA WHICH MAY BE | | | APPLICABLE. WIL YOU BE PROVIDING AT LEAST ONE SPACE | | | COMPLYING WITH FBC-ACCESSIBILITY SECTION 502? | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2016-11-04 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2016-11-04 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2016-11-04 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2016-06-11 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2016-06-11 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2016-06-11 |
Time |
|
Sent To |
I |
|
| Notes |
| 2016-06-11 07:40:52 | REVIEW THE DIMENSIONS AS SHOWN. | | | 16FEET VS 18FEET (DETAIL VS SITE PLAN) 16' WITH A TWO | | | FOOT OVERHANG WOULD BE OK. | | | | | | WHEEL STOPS WOULD HAVE TO BE ANCHORED ON ASPHALT OR | | | CONCRETE SURFACE NOT IN LANDSCAPE AREA. YOUR DRAWING | | | DOES NOT SPECIFY PARKING SURFACE, CONCRETE OR ASPHALT? | | | | | | SHOW DETAIL OF PROPOSED APRON (REMOVING SIDEWALK TO | | | ACCESS PARKING? ) ANY PROPOSED DRIVEWAY APRON MUST BE | | | 6" THICK 3000 PSI CONCRETE. | | | | | | CITY STANDARD STRIPPING IS "DOUBLE STRIPE" WHITE NOT | | | SINGLE STRIPE. | | | | | | VERIFY DIMENSION FROM BACK OF SIDEWALK TO BUILDING | | | WALL. I BELIEVE IT MAY BE SMALLER THAN 19.96' AS SHOWN. | | | | | | IS YOUR PARKING OFF THE ALLEY OR 4TH STREET. | | | | | | "FIRE RATING" NOTE SHOULD BE EXCLUDED. | | | | | | PROVIDE ON PLAN "PERVIOUS AREA IN SQUARE FEET, | | | IMPERVIOUS AREA IN SQUARE FEET AND BUILDING AREA IN | | | SQUARE FEET" INCLUDE YOUR PROPOSED PARKING. | | | | | | THANK YOU! | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | PUBLIC WORKS DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-11-18 |
|
|
Cont ID |
|
| Sent By |
gdorsan |
Date |
2016-11-18 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
gdorsan |
Date |
2016-09-14 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2016-09-14 12:49:29 | RESUB ROUTED TO NJWIRA VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-06-13 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-06-13 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-05-26 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2016-05-27 12:57:57 | ROUTED TO ZONING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2016-09-19 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2016-09-19 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-09-15 |
Time |
09:27 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2016-06-08 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2016-06-08 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2016-06-08 |
Time |
09:23 |
Sent To |
B |
|
| Notes |
| 2016-06-08 09:25:21 | 6/8/16- FAILED | | | 1. NO ALTERATIONS IN THE NUMBER OF PARKING SPACES. | | | 2. PARKING MUST BE 18FT. IN DEPTH. DRAWINGS SHOW THE | | | DEPTH BEING 16FT. | | | | | | PLEASE CONTACT: | | | NATHAN WIRA | | | (561)822-1442 | | | [email protected] | | | |
|
|
|