Plan Review Details - Permit 16051166
Plan Review Stops For Permit 16051166
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-10-13 Cont ID  
Sent By cthroop Date 2016-10-13 Time 08:56 Rev Time 0.00
Received By cthroop Date 2016-10-13 Time 08:47 Sent To ENG
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-06-13 Cont ID  
Sent By skennedy Date 2016-06-13 Time 09:28 Rev Time 0.00
Received By skennedy Date 2016-06-13 Time 09:28 Sent To  
Notes
2016-06-13 09:51:521ST REVIEW: FBC 2014 5TH ED
  
 DENIED: SHOW ACCURATE INFORMATION PER FBC 107
  
 THE PLAN INDICATES THE BUILDING IS A "RESIDENCE"
 ALTHOUGH RECORDS INDICATE IT IS A MULTI FAMILY DWELLING
 CONSISTING OF 3 OR 4 DWELLING UNITS. PLEASE ACCURATELY
 REFLECT ON THE PLAN THE QUANTITY OF DEWLLING UNITS AND
 USE OF THE STRUCTURE THE PARKING LOT IS INTENDED TO
 SERVE. PLEASE ADDITIONALLY INDICATE IF YOU HAVE INTENT
 TO UPGRADE AS TO ACCESSIBILITY CRITERIA WHICH MAY BE
 APPLICABLE. WIL YOU BE PROVIDING AT LEAST ONE SPACE
 COMPLYING WITH FBC-ACCESSIBILITY SECTION 502?
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2016-11-04 Cont ID  
Sent By mgonzale Date 2016-11-04 Time   Rev Time 1.00
Received By mgonzale Date 2016-11-04 Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2016-06-11 Cont ID  
Sent By Mgonzale Date 2016-06-11 Time   Rev Time 1.00
Received By mgonzale Date 2016-06-11 Time   Sent To I
Notes
2016-06-11 07:40:52REVIEW THE DIMENSIONS AS SHOWN.
 16FEET VS 18FEET (DETAIL VS SITE PLAN) 16' WITH A TWO
 FOOT OVERHANG WOULD BE OK.
  
 WHEEL STOPS WOULD HAVE TO BE ANCHORED ON ASPHALT OR
 CONCRETE SURFACE NOT IN LANDSCAPE AREA. YOUR DRAWING
 DOES NOT SPECIFY PARKING SURFACE, CONCRETE OR ASPHALT?
  
 SHOW DETAIL OF PROPOSED APRON (REMOVING SIDEWALK TO
 ACCESS PARKING? ) ANY PROPOSED DRIVEWAY APRON MUST BE
 6" THICK 3000 PSI CONCRETE.
  
 CITY STANDARD STRIPPING IS "DOUBLE STRIPE" WHITE NOT
 SINGLE STRIPE.
  
 VERIFY DIMENSION FROM BACK OF SIDEWALK TO BUILDING
 WALL. I BELIEVE IT MAY BE SMALLER THAN 19.96' AS SHOWN.
  
 IS YOUR PARKING OFF THE ALLEY OR 4TH STREET.
  
 "FIRE RATING" NOTE SHOULD BE EXCLUDED.
  
 PROVIDE ON PLAN "PERVIOUS AREA IN SQUARE FEET,
 IMPERVIOUS AREA IN SQUARE FEET AND BUILDING AREA IN
 SQUARE FEET" INCLUDE YOUR PROPOSED PARKING.
  
 THANK YOU!
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 PUBLIC WORKS DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-11-18 Cont ID  
Sent By gdorsan Date 2016-11-18 Time 14:22 Rev Time 0.00
Received By gdorsan Date 2016-09-14 Time 12:49 Sent To  
Notes
2016-09-14 12:49:29RESUB ROUTED TO NJWIRA VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-06-13 Cont ID  
Sent By skennedy Date 2016-06-13 Time 09:28 Rev Time 0.00
Received By skennedy Date 2016-05-26 Time 12:57 Sent To  
Notes
2016-05-27 12:57:57ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2016-09-19 Cont ID  
Sent By njwira Date 2016-09-19 Time 11:50 Rev Time 0.00
Received By njwira Date 2016-09-15 Time 09:27 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2016-06-08 Cont ID  
Sent By njwira Date 2016-06-08 Time 09:23 Rev Time 0.00
Received By njwira Date 2016-06-08 Time 09:23 Sent To B
Notes
2016-06-08 09:25:216/8/16- FAILED
 1. NO ALTERATIONS IN THE NUMBER OF PARKING SPACES.
 2. PARKING MUST BE 18FT. IN DEPTH. DRAWINGS SHOW THE
 DEPTH BEING 16FT.
  
 PLEASE CONTACT:
 NATHAN WIRA
 (561)822-1442
 [email protected]
  