Plan Review Details - Permit 16051135
| Plan Review Stops For Permit 16051135 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-07-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-07-26 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-07-26 |
Time |
11:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-06-21 |
Time |
19:01 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-06-21 |
Time |
19:01 |
Sent To |
|
|
| Notes |
| 2016-06-21 19:00:50 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE PRODUCT APPROVALS FOR THE FRENCH DOORS DO NOT | | | SPECIFY ANY ANCHORS FOR ATTACHING TO THE 2" X 4" | | | ALUMINUM TUBE MULLION. THE ENGINEER WILL HAVE TO | | | SPECIFY THE ANCHORS AND SPACING THAT WILL PROVIDE AN | | | EQUIVALENT CONNECTION. SEE SHEET 10 OF THE FRENCH DOOR | | | PRODUCT APPROVAL DRAWINGS. FBC-R301.1 | | | | | | 2) THE ENGINEER'S PLANS SPECIFY 3" THICK EPS FOAM CORE | | | WALL PANELS WITH 0.060" (14GA.) ALUMINUM SKINS. THE | | | PRODUCT APPROVAL THAT WAS SUBMITTED (FL19974) IS FOR 4" | | | AND 6" THICK EPS FOAM CORE WALL PANELS WITH 26 GAUGE | | | STEEL SKINS. PLEASE COORDINATE THE PRODUCT APPROVALS | | | AND THE PLANS. FBC 107.2.1 | | | | | | 3) THE ANCHORS THAT WILL CONNECT THE CHANNELS TO THE | | | CONCRETE FLOOR, WALL AND TIE BEAM ARE NOT SPECIFIED ON | | | THE PLANS. ON SECTIONS A AND D THE ANCHORS ARE TAGGED | | | WITH NUMBER 6, WHICH IS THE NOTE FOR THE SHOP WELD FOR | | | THE BASE AND CAP PLATES ON THE ALUMINUM TUBE MULLION. | | | FBC 107.2.1 ON SHEET 2 OF FL19974, 5/8" DIA. J-BOLTS | | | ARE SPECIFIED TO ANCHOR THE BOTTOM CHANNEL. | | | | | | 4) SHEET 2 OF THE PRODUCT APPROVAL (FL19974) SPECIFIES | | | THAT THE STRUCTURAL PANELS ARE ATTACHED TO THE CHANNEL | | | WITH SCREWS ON BOTH SIDES. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-05-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-05-27 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-05-26 |
Time |
18:41 |
Sent To |
|
|
| Notes |
| 2016-05-27 07:44:58 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE PRODUCT APPROVAL FOR THE STRUCTURAL EPS FOAM | | | CORE WALL PANEL IS PENDING FBC APPROVAL. IT HAS NOT | | | BEEN APPROVED AT THIS TIME. | | | | | | 2) THE STRUCTURAL EPS PANEL IS SHOWN AS BEING INSTALL | | | IN A WAY THAT IS NOT CONSISTENT WITH THE PRODUCT | | | APPROVAL. FBC 104.11 ALLOWS ALTERNATIVE MATERIALS, | | | DESIGN AND METHODS OF CONSTRUCTION AND EQUIPMENT, | | | PROVIDED THAT ANY SUCH ALTERNATIVE HAS BEEN APPROVED BY | | | THE BUILDING OFFICIAL. IN ORDER FOR THIS | | | PRODUCT/APPLICATION TO BE APPROVED, A RATIONAL ANALYSIS | | | FROM A FLORIDA LICENSED ENGINEER ALONG WITH SUPPORTING | | | DATA IS REQUIRED TO BE SUBMITTED FOR REVIEW. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-07-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-07-26 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-07-12 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2016-07-12 12:42:04 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-06-21 |
Time |
19:01 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-06-17 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2016-06-20 10:02:28 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-05-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-05-27 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-05-25 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2016-05-26 10:23:59 | BLDG MISC 1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy