| 2016-06-13 14:53:55 | BUILDING PLAN REVIEW |
| | W. P. B. REVISION: 16051002 |
| | W. P. B. PERMIT: 15050177 |
| | ADD: 1152 OKEECHOBEE RD |
| | CONT: NEWBOLD CONSTRUCTION |
| | TEL: (561)644-5764 |
| | E-MAIL: |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: MON. JUNE 13/2016 |
| | ACTION: DENIED |
| | |
| | 1) PLEASE NOTE THAT THE CITY APPROVED PLANS ON FILE ARE |
| | BY ARCHITECT BERNARD JONES. PLEASE PROVIDE A LETTER |
| | FROM THE ENGINEER THAT HE IS GOING TO BE THE DESIGNER |
| | OF RECORD FOR THE PROJECT, TAKING OVER THE PROJECT |
| | SINCE THERE WAS A ARCHITECT BEFORE. |
| | |
| | 2) SHEET S1 AND S2 THERE APPEARS TO BE A DISCREPANCY IN |
| | THE RAMP THAT IS IN FRONT OF THE VIP AREA. AS DRAWN |
| | THERE SHOULD BE ANOTHER EITHER SET OF STAIRS OR RAMP. I |
| | BELIEVE THE RAMP IS SUPPOSE TO TIE INTO THE VIP |
| | PLATFORM FOR THE ACCESSIBLE ENTRY/ EXIT. 2010 |
| | FBC-ACCESSIBILITY CODE 402.2 COMPONENTS. |
| | ACCESSIBLE ROUTES SHALL CONSIST OF ONE OR MORE OF THE |
| | FOLLOWING COMPONENTS: WALKING SURFACES WITH A RUNNING |
| | SLOPE NOT STEEPER THAN 1:20, DOORWAYS, RAMPS, CURB |
| | RAMPS EXCLUDING THE FLARED SIDES, ELEVATORS, AND |
| | PLATFORM LIFTS. ALL COMPONENTS OF AN ACCESSIBLE ROUTE |
| | SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF |
| | CHAPTER 4 AND 208.3.1. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |