Plan Review Details - Permit 16050980
| Plan Review Stops For Permit 16050980 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-06-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-06-09 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-06-09 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2016-06-09 15:49:59 | CONTRACTOR E-MAILED PAGE 35 OF 42 OF NOA 14-0529.02. | | | JG. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-06-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-06-03 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-06-03 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2016-06-03 16:04:44 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS. | | | CODE: FBC, 5TH EDITION (2014). | | | | | | 1- FLAT ROOF: | | | ORIGINAL COMMENT: | | | (A) CLEARLY IDENTIFY WHICH APPROVED ASSEMBLY FROM NOA | | | 14-0529.02 SUBMITTED IS GOING TO BE INSTALLED TO VERIFY | | | COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. R301 OF | | | FBC-RESIDENTIAL, 5TH EDITION (2014). | | | RESPONSE: THE DESIGN PRESSURES OF THE SELECTED ASSEMBLY | | | ON PAGE 24 OF 42 IS GOOD FOR -52.5 PSF. THE DESIGN | | | PRESSURES FOR THE PERIMETER AND CORNER AREAS OF THE | | | ROOF ARE HIGHER. NEED TO PROVIDE SIGNED AND SEALED RAS | | | 117 CALCULATIONS AS REQUIRED BY GENERAL LIMITATION #7 | | | ON LAST PAGE OF NOA SUBMITTED. | | | | | | ORIGINAL COMMENT: | | | 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS AND | | | CONTRACTOR'S OVERHEAD AND PROFIT AS REQUIRED BY SEC. | | | 109.3 CITY AMENDMENTS. PROVIDE COPY OF SIGNED CONTRACT | | | TO PERFORM THE JOB. | | | RESPONSE: PROVIDE COPY OF CONTRACT SIGNED BY THE OWNER | | | AND THE CONTRACTOR FOR BUILDING OFFICIAL APPROVAL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-05-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-05-24 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-05-24 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2016-05-24 11:29:42 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS. | | | CODE: FBC, 5TH EDITION (2014). | | | | | | 1- FLAT ROOF: | | | (A) CLEARLY IDENTIFY WHICH APPROVED ASSEMBLY FROM NOA | | | 14-0529.02 SUBMITTED IS GOING TO BE INSTALLED TO VERIFY | | | COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. R301 OF | | | FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | | | (B) IF SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | | RAS 117 WILL BE REQUIRED. NOTE: ONLY ASSEMBLIES THAT | | | ARE LIMITED BY GENERAL LIMITATION # 7 ARE ALLOWED TO | | | PERFORM RAS 117 CALCULATIONS. ASSEMBLIES LIMITED BY | | | GENERAL LIMITATION #9 DON'T ALLOW RAS 117 CALCULATIONS. | | | | | | 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS AND | | | CONTRACTOR'S OVERHEAD AND PROFIT AS REQUIRED BY SEC. | | | 109.3 CITY AMENDMENTS. PROVIDE COPY OF SIGNED CONTRACT | | | TO PERFORM THE JOB. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-06-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-06-09 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-06-09 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2016-06-09 15:47:10 | HI JULIO | | | ? ? ? ? WE HAVE DECIDED TO SELECT A SYSTEM SUITABLE TO | | | THE REQUIRED DESIGN PRESSURE. PLEASE SEE ATTACHED | | | SELECTION TO REPLACE ORIGINAL CHOICE ON SUBMITTED. | | | THANKS? | | | | | | ? | | | REAL PROPERTY ENTERPRISES, LLC | | | GENERAL CONSTRUCTION & ROOFING SERVICES | | | TEL: 561 693 1377 | | | 866 298 1632 | | | FAX 866 543 1931 | | | | | | ?OMARI?? CELL (561) 251 2319 | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-06-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-06-03 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-06-03 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2016-06-03 15:48:18 | RECEIVED E-MAIL ADDRESSING COMMENTS. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-05-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-05-24 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-05-23 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2016-05-23 14:34:18 | JGOMEZ |
|
|
|