|
 |
 |
 |
 |
 |
Plan Review Details - Permit 16050949
| Plan Review Stops For Permit 16050949 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-05-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-05-28 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-05-28 |
Time |
14:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-06-16 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-06-16 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-06-16 |
Time |
11:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-05-25 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-05-25 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-05-25 |
Time |
13:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2016-05-24 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2016-05-24 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2016-05-24 |
Time |
09:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-06-16 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-06-16 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-06-16 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2016-06-15 09:44:14 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-06-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-05-25 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-05-20 |
Time |
09:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2016-06-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-06-15 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-06-15 |
Time |
14:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-05-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-05-25 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-05-25 |
Time |
17:37 |
Sent To |
|
|
| Notes |
| 2016-05-25 17:52:48 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #16050949 | | | 5/25/16 | | | | | | 1) INDICATE THE MAKE AND MODEL AND COOLING AND HEATING | | | CAPACITIES OF THE EXISTING AC SYSTEM. | | | 2) THE 8X12" TRUNK AND 10" ROUND DUCT ARE UNDERSIZED | | | FOR 750 CFM'S OF SUPPLY AIR PER BY STANDARD ACCA DUCT | | | SIZING CALCULATORS. PROVIDE A MINIMUM 8X16" TRUNK AND | | | 12" ROUND DUCT AND SHOW THEIR POINT OF CONNECTION. | | | 3) THE 6" RETURN AIR TRANSFER DUCT FROM BEDROOM-3 TO | | | THE LIVING ROOM SHALL BE MINIMUM 8"- SECTION 601.5 | | | FBC-14 MECHANICAL. | | | 4) PROVIDE AN EXHAUST VENTILATION PLAN FOR THE NEW | | | COOKTOP IN COMPLIANCE WITH SECTION 505.1. SHOW THE HOOD | | | AND EXHAUST DUCT SIZES, EXHAUST DUCT RUN, AND | | | TERNINATION LOCATION. SUBMIT MANUFACTURER'S | | | SPECIFICATIONS FOR THE COOKTOP AND THE EXHAUST SYSTEM. | | | PLEASE NOTE THAT MAKEUP AIR WILL BE REQUIRED IF THE | | | SYST3EM IS CAPABLE OF EXHAUSTING IN EXCESS OF 400 | | | CFM'S. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-06-01 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-06-01 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-06-01 |
Time |
16:28 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |