| Plan Review Stops For Permit 16050731 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2016-07-11 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2016-07-11 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2016-07-11 |
Time |
10:34 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2016-06-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-06-28 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2016-06-27 |
Time |
11:02 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2016-06-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-06-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-06-15 |
Time |
16:50 |
Sent To |
PC |
|
| Notes |
| 2016-06-15 16:54:20 | 2ND REVIEW | | | | | | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THE PERMIT PLAN IS SUBMITTED UNDER THE ARCHITECT AND | | | THE ARCHITECT'STITLE BLOCK AND IS A VIOLATION OF | | | FLORIDA STATUTE AS IS REJECTED. | | | | | | COMPLIED | | | | | | 2) THE SHOP DRAWINGS ARE TO BE SUBMITTED UNDER A | | | QUALIFIED ENGINEER'S REVIEW AND/OR TITLE BLOCK. | | | | | | COMPLIED. | | | | | | 3) THE SUBMITTED PLANS ARE TOO SMALL AND UNREADABLE. | | | PROVIDE LARGER AND READABLE PLANS. | | | | | | DID NOT COMPLY, SEE ALSO MECHANICAL COMMENT. | | | | | | 4) SHEET M 1 - THE HORIZONTAL VIEW INDCATES INCOMPLETE | | | HOOD VENT COVERAGE AS IT SHOWS IT SHORT ON ONE SIDE OF | | | COVERING THE PROPOSED EQUIPMENT. THE HOOD VENT SHALL | | | COVER ALL EQUIPMENT PER NFPA AND MECHANICAL CODES. | | | | | | LARGER VIEW WITH MORE CLARITY MAY ADDRESS THIS ISSUE. | | | | | | ADDITIONAL COMMENTS MAY BE PROVIDED ON THE RE-SUBMITTAL | | | OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2016-05-20 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-05-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-05-20 |
Time |
15:50 |
Sent To |
M |
|
| Notes |
| 2016-05-20 16:15:17 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THE PERMIT PLAN IS SUBMITTED UNDER THE ARCHITECT AND | | | THE ARCHITECT'STITLE BLOCK AND IS A VIOLATION OF | | | FLORIDA STATUTE AS IS REJECTED. | | | | | | 2) THE SHOP DRAWINGS ARE TO BE SUBMITTED UNDER A | | | QUALIFIED ENGINEER'S REVIEW AND/OR TITLE BLOCK. | | | | | | 3) THE SUBMITTED PLANS ARE TOO SMALL AND UNREADABLE. | | | PROVIDE LARGER AND READABLE PLANS. | | | | | | 4) SHEET M 1 - THE HORIZONTAL VIEW INDCATES INCOMPLETE | | | HOOD VENT COVERAGE AS IT SHOWS IT SHORT ON ONE SIDE OF | | | COVERING THE PROPOSED EQUIPMENT. THE HOOD VENT SHALL | | | COVER ALL EQUIPMENT PER NFPA AND MECHANICAL CODES. | | | | | | ADDITIONAL COMMENTS MAY BE PROVIDED ON THE RE-SUBMITTAL | | | OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2016-07-11 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2016-07-11 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2016-07-05 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2016-07-05 09:34:15 | HAND DELIVERED TO CHRIS COLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-06-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-06-28 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-06-23 |
Time |
13:47 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-06-15 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-06-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-06-09 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2016-06-10 10:31:05 | RESUB ROUTED TO FIRE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-05-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-05-24 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-05-18 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2016-05-18 11:44:53 | ROUTED TO FIRE |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2016-07-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-07-05 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-07-05 |
Time |
09:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2016-06-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-06-28 |
Time |
07:29 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-06-28 |
Time |
07:28 |
Sent To |
FIRE |
|
| Notes |
| 2016-06-28 07:35:40 | 3RD REVIEW: FBC 2014 MECHANICAL | | | PERMIT #16050731 | | | 6/28/16 | | | | | | 1) THE TYPE II EXHAUST FAN SHALL TERMINATE 30" ABOVE | | | THE ROOF SURFACE- SEE SECTION 506.4.2(4). | | | | | | 2) AS PREVIOUSLY REQUESTED PROVIDE AN EQUIPMENT | | | SCHEDULES ON THE PLAN THAT INCLUDES THE MAKE AND MODEL | | | OF THE FAN. THE SUBMITTED NOA HAS MULTIPLE MODELS AND | | | SIZES. PLEASE CIRCLE, HIGHLIGHT, OR OTHERWISE MARK THE | | | MODEL AND SIZE OF THE FAN AND ALL OTHER APPLICABLE | | | DETAILS ON THE NOA. | | | | | | 3) THE EXHAUST APPEARS TO BE TERMINATING LESS THAN 30" | | | FROM THE VERTICAL WALL ABOVE THE ROOF- SECTION | | | 506.4.2(5). PLEASE NOTE THAT IF THE WALL IS ALSO A FIRE | | | WALL BETWEEN TWO PROPERTIES, THE EXHAUST TERMINATION | | | SHALL NOT BE LESS THAN 10' FROM THE WALL. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-06-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-06-13 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-06-13 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2016-06-13 11:12:18 | 2ND REVIEW: FBC 2014 MECHANICAL | | | PERMIT #16050731 | | | 6/13/16 | | | | | | 1) INDICATE THE EXHAUST FAN TERMINATION HEIGHT ABOVE | | | THE ROOF SURFACE PER SECTION 506.4.2(4). | | | | | | 2) PROVIDE AN EQUIPMENT SCHEDULE FOR THE FAN AND SUBMIT | | | A FL. PRODUCT APPROVAL OR MIAMI-DADE NOA. | | | | | | 3) PLEASE ENLARGE ALL PRINT AND SCHEDULES SHOWN IN | | | DETAILS #1, 2, & 3- SECTION 107.2.1 WPB AMENDMENTS TO | | | THE FBC. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-05-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-05-24 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-05-24 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2016-05-24 14:05:21 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #16050731 | | | 5/24/16 | | | | | | 1) SUBMIT COMPLETE DRAWINGS, EQUIPMENT SCHEDULES, AND | | | EXHAUST AND AIR BALANCE CALCULATIONS FOR THE PROPOSED | | | TYPE II HOOD. THE SUBMITTED DRAWINGS ARE NOT ACCEPTABLE | | | BECAUSE THEY COPIES, ARE IMCOMPLETE, AND DO NOT BEAR | | | THE ARCHITECT'S RAISED SIGNATURE AND SEAL. SHOP | | | DRAWINGS FOR THE PROPOSED EXHAUST HOOD MAY BE SUBMITTED | | | BUT THEY MUST BE REVIEWED AND APPROVED | | | BY THE ARCHITECT OF RECORD. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|