| Plan Review Stops For Permit 16050607 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-07-29 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-07-29 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-07-29 |
Time |
12:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-06-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-06-21 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-06-21 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2016-06-21 15:33:42 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER ? PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 1ST REVIEW | | | DATE: 6/21/16 | | | ACTION: DENIED | | | | | | 1. PROVIDE FLOOR PLAN INDICATING LOCATION OF ALL WORK. | | | IDENTIFY WALL TYPES TO BE REMOVED AND IN-FILLED. | | | IDENTIFY WHAT WALLS WILL HAVE JUST DRYWALL REMOVED. | | | INCLUDE DEMENSIONS. | | | 2. DESIGNER TO SIGN DRAWINGS. | | | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. (SEE ALSO SECTION 107.3.5). | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-07-18 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-07-18 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-07-18 |
Time |
16:32 |
Sent To |
|
|
| Notes |
| 2016-07-29 12:54:33 | SUPERVISOR OVER RIDE. | | 2016-07-18 17:36:38 | REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | - ALL KITCHEN COUNTERTOP RECEPTACLES MUST BE GFCI | | | PROTECTED NEC 210.8 (A)(6) / FBC R E3902.6 ( MARK ON | | | PLANS ) | | | | | | - A RECEPTACLE IS SHOWN BEHIND OR ON TOP OF THE | | | COUNTERTOP SPACE OCCUPIED BY THE RANGE CLARIFY SPACING | | | OR CHANGE THE SYMBOL IF THE INTENT IS A 220 V OUTLET | | | FOR THE RANGE. NEC 210.52(C)(4) / FBC R E3901.4.4 | | | | | | - ALL BATHROOM RECEPTACLES SHALL BE GFCI PROTECTED NEC | | | 210.8(A)(1) / FBC R E3902.1 ( MARK ON PLANS ) | | | | | | - SMOKE ALARMS REQUIRED PER RESIDENTIAL CODE SECTIONS | | | 314 & 315, IF EXISTING MARK ON PLANS. | | | | | | - ALL NEWLY INSTALLED LIGHTING SHALL BE HIGH EFFICIENCY | | | AND IC RATED PLEASE ADD A NOTE. FBC E R404.1 | | | | | | THE ANSWER TO MY INITIAL COMMENTS IN YOUR RESPONSE | | | LETTER WERE CORRECT HOWEVER NOTHING WAS REFLECTED ON | | | THE PLANS PLEASE ADD THE NOTES IN THE FLOOR PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-05-23 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-05-23 |
Time |
18:33 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-05-23 |
Time |
18:17 |
Sent To |
|
|
| Notes |
| 2016-05-23 18:34:37 | JOB PERMIT NUMBER: 16050607 | | | JOB ADDRESS: 122 WORTH COURT NORTH | | | WEST PALM BEACH FLORIDA | | | DATE: MAY 23 2016 | | | ELECTRICAL PLAN REVIEW COMMENTS | | | | | | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF | | | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, | | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | | | | - NEC 210.52(C)(1) WALL COUNTERTOP SPACES. A RECEPTACLE | | | OUTLET SHALL BE INSTALLED AT EACH WALL COUNTERTOP SPACE | | | THAT IS 12 IN. OR WIDER. RECEPTACLE OUTLETS SHALL BE | | | INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE | | | THAN 24 IN. MEASURED HORIZONTALLY FROM A RECEPTACLE | | | OUTLET IN THAT SPACE. | | | - NEC 210.52(C)(2)(3) ISLAND & PENINSULAR COUNTERTOP | | | SPACES. AT LEAST ONE RECEPTACLE OUTLET SHALL BE | | | INSTALLED AT EACH ISLAND & PENINSULAR COUNTERTOP. | | | - NEC 210.8(A)(6)(7) GFCI PROTECTION REQUIRED IN | | | KITCHENS WHERE RECEPTACLES SERVE THE COUNTER-TOP | | | SURFACES AND ALSO WITHIN 6? OF THE OUTER EDGE OF SINKS. | | | - SMOKE ALARMS REQUIRED PER RESIDENTIAL CODE 314 AND | | | 315. | | | - NEC 406.11 TAMPER-RESISTANT RECEPTACLES IN DWELLING | | | UNITS. IN ALL AREAS SPECIFIED IN 210.52, ALL 125-VOLT, | | | 15 AND 20 AMPERE RECEPTACLES SHALL BE LISTED TAMPER | | | RESISTANT RECEPTACLES. | | | - FBC-E C402.4.8 RECESSED LIGHTING. RECESSED LIGHTING | | | INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE IC | | | RATED AND BE SEALED TO LIMIT AIR LEAKAGE BETWEEN | | | CONDITIONED & UNCONDITIONED SPACES. | | | | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | | MENTIONED DEFICIENCIES. | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | | STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD | | | INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE | | | OR ACTION TO SAME. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS FOR COMPARISON. | | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | FBC 2014 5TH ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2016-07-29 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-07-29 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-07-29 |
Time |
12:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2016-05-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-05-20 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-05-20 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2016-05-20 16:12:02 | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | GAS COMMENTS: | | | | | | 1. THE FLOOR PLAN OF KITCHEN SHOWS RANGE ON OUT SIDE | | | WALL WITH THE MEETER RITE OUT SIDE YOUR GAS DRAWING | | | SHOWS IT AT 20FT PLEASE CLARIFY . PER WPB AMEND. TO FBC | | | 107.2.1 | | | | | | 2. SHOW THE EHD NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING USED. WPB AMENDMENTS | | | TO FBC SEC. 107.2.1. | | | | | | 3.SHOW LOCATION OF REGULATOR . PER WPB AMEND. TO FBC | | | 107.2.1 | | | | | | 4. THE INFORMATION WAS CUT OF ON THE COPY OF THE GAS | | | PAGE THAT WAS SUBMITTED PLEASE PROVIDE NEW ONE WITH ALL | | | INFORMATION CLEAR. . PER WPB AMEND. TO FBC 107.2.1 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-07-29 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-07-29 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-07-05 |
Time |
10:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-06-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-06-21 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-05-16 |
Time |
12:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2016-07-29 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-07-29 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-07-29 |
Time |
12:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-06-09 |
|
|
Cont ID |
|
| Sent By |
jvalido |
Date |
2016-06-09 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
jvalido |
Date |
2016-06-09 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2016-06-09 10:23:26 | CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA | | | BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION | | | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS | | | SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING | | | OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | | BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | | WHERE | | | QUALITY IS ESSENTIAL TO CONFORMITY WITH THE TECHNICAL | | | CODES. SUCH INFORMATION SHALL BE SPECIFIC, AND THE | | | TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE OR IN | | | PART, NOR SHALL THE TERM "LEGAL" OR | | | ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5) | | | | | | PROVIDE DUCT DIMENSIONS. | | | PROVIDE NAME AND SIGNATURE OF THE PERSON RESPONSIBLE | | | FOR THE DESIGN. | | | | | | | | | FBC MECHANICAL 2014 | | | | | | FYI | | | | | | M1503.4 MAKEUP AIR REQUIRED. | | | EXHAUST HOOD SYSTEMS CAPABLE OF EXHAUSTING IN EXCESS OF | | | 400 CUBIC FEET PER MINUTE (0.19 M3/S) SHALL BE PROVIDED | | | WITH MAKEUP AIR AT A RATE APPROXIMATELY EQUAL TO THE | | | EXHAUST AIR RATE. SUCH MAKEUP AIR SYSTEMS SHALL BE | | | EQUIPPED WITH A MEANS OF CLOSURE AND SHALL BE | | | AUTOMATICALLY CONTROLLED TO START AND OPERATE | | | SIMULTANEOUSLY WITH THE EXHAUST SYSTEM. | | | | | | EXCEPTION: IN A SINGLE-FAMILY DWELLING, MAKE-UP AIR IS | | | NOT REQUIRED FOR RANGE HOOD EXHAUST SYSTEMS CAPABLE OF | | | EXHAUSTING: | | | | | | (A) FOUR HUNDRED CUBIC FEET PER MINUTE OR LESS; OR | | | | | | (B) MORE THAN 400 CUBIC FEET PER MINUTE BUT NO MORE | | | THAN 800 CUBIC FEET PER MINUTE IF THERE ARE NO GRAVITY | | | VENT APPLIANCES WITHIN THE CONDITIONED LIVING SPACE OF | | | THE STRUCTURE. | | | | | | JORGE VALIDO | | | WPB MECHANICAL INSPECTOR/PLANS EXAMINER | | | [email protected] | | | 561-805-6732 | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
P |
Date |
2016-07-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-07-27 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-07-27 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2016-07-27 14:51:11 | SUBSTANTIAL IMPROVEMENT 12100037; ORIGINAL ELEVATION | | | CERTIFICATE PROVIDED AT THAT TIME | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-07-29 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-07-29 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-07-29 |
Time |
12:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-05-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-05-20 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-05-20 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2016-05-20 16:02:05 | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE PROVIDE PLUMBING RISER DIAGRAM FOR ALL NEW | | | WORK. PER WPB AMEND. TO FBC SEC. 107.3.5.3(11) | | | | | | 2. PLEASE PROVIDE FULL FLOOR PLAN EXISTING AND PROPOSED | | | . PER WPB AMEND. TO FBC 107.2.1 | | | | | | |
|
|