Plan Review Details - Permit 16050580
Plan Review Stops For Permit 16050580
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-06-02 Cont ID  
Sent By shill Date 2016-06-02 Time 11:03 Rev Time 0.00
Received By shill Date 2016-06-02 Time 11:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-05-14 Cont ID  
Sent By shill Date 2016-05-14 Time 14:24 Rev Time 0.00
Received By shill Date 2016-05-14 Time 14:24 Sent To  
Notes
2016-05-14 14:25:04****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. FBC 5TH ED. RESIDENTIAL905.2.2, SPECIFY NUMBER OF
 LAYERS OF UNDERLAYMENT FOR THE SHINGLE PORTION OF THE
 ROOF.
  
 2. TWO COMPLETE SETS OF DOCUMENTS REQUIRED, FBC 107.
 (ONLY ONE ROOF PLAN SUBMITTED)
  
 3. THE FLAT DECK ASSEMBLY HAS A LIMITATION OF -75PSF
 WHICH DOES NOT MEET THE REQUIREMENT FOR ZONE 3 (-95.7).
 FBC 5TH ED. RESIDENTIAL 301.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-05-14 Cont ID  
Sent By shill Date 2016-05-14 Time 14:32 Rev Time 0.00
Received By shill Date 2016-05-13 Time 15:33 Sent To  
Notes
2016-05-13 15:33:26SHILL