Plan Review Details - Permit 16050568
Plan Review Stops For Permit 16050568
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-06-10 Cont ID  
Sent By cthroop Date 2016-06-10 Time 08:47 Rev Time 0.00
Received By cthroop Date 2016-06-10 Time 08:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-05-25 Cont ID  
Sent By shill Date 2016-05-25 Time 13:52 Rev Time 0.00
Received By shill Date 2016-05-25 Time 13:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-06-09 Cont ID  
Sent By mvaldes Date 2016-06-09 Time 13:06 Rev Time 0.00
Received By mvaldes Date 2016-06-09 Time 13:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-05-19 Cont ID  
Sent By vperez Date 2016-05-19 Time 08:59 Rev Time 0.00
Received By vperez Date 2016-05-19 Time 08:59 Sent To B
Notes
2016-05-19 09:13:51INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011 NEC
 COMMENTS:
  
 1. PLEASE PROVIDE AND REFLECT ON ELECTRICAL DRAWINGS
 THE ELECTRICAL DATA INFORMATION, EXAMPLE VOLTAGE, TOTAL
 AMPS, CIRCUITS POWER SUPPLY INFORMATION ETC. FBC
 107.3.5- MINIMUM PLAN REVIEW CRITERIA
 2. ADD GENERAL NOTES TO INDICATE THAT ALL MATERIALS AND
 FASTENERS MEET 3004.4
 3. ALL ELECTRICAL COMPONENTS ARE UL LISTED AND APPROVED
 (GENERAL NOTE)
 4. SIGN TO BE GROUNDED ACCORDING TO NEC 600.7 (GENERAL
 NOTE)
 5. SIGN TO BE MANUFACTURED AND LISTED NEC 600.3 AND
 MARKED PER NEC 600.4(GENERAL NOTE)
 6. ALL BRANCH CIRCUITS PER NEC 600.5(B)1 AND B2(GENERAL
 NOTE)
 7. SIGN TO BE CONTROLLED BY PHOTOCELL OR TIME CLOCK PER
 FBC 2014 ENERGY CONSERVATION C405.2.4(GENERAL NOTE)
 8. VISIBLE 20AMP DISCONNECT PER SIGN PER CIRCUIT NEC
 600.6 A1 AND 2. (GENERAL NOTE)
 9. PLEASE FEEL FREE TO CONTACT ME SHOULD YOU HAVE ANY
 QUESTIONS REGARDING THIS PROJECT.
  
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-06-10 Cont ID  
Sent By cthroop Date 2016-06-10 Time 08:47 Rev Time 0.00
Received By cthroop Date 2016-06-06 Time 14:13 Sent To  
Notes
2016-06-06 14:14:05RESUB ROUTED TO NJWIRA VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-05-25 Cont ID  
Sent By shill Date 2016-05-25 Time 13:52 Rev Time 0.00
Received By shill Date 2016-05-13 Time 14:15 Sent To  
Notes
2016-05-13 14:15:48ROUTED TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2016-06-07 Cont ID  
Sent By njwira Date 2016-06-07 Time 16:53 Rev Time 0.00
Received By njwira Date 2016-06-07 Time 16:53 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2016-05-17 Cont ID  
Sent By njwira Date 2016-05-17 Time 11:48 Rev Time 0.00
Received By njwira Date 2016-05-17 Time 11:48 Sent To E
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved