Plan Review Details - Permit 16050520
Plan Review Stops For Permit 16050520
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-07-05 Cont ID  
Sent By rmcdouga Date 2016-07-05 Time 10:52 Rev Time 0.00
Received By rmcdouga Date 2016-07-05 Time 10:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-06-15 Cont ID  
Sent By rmcdouga Date 2016-06-15 Time 14:31 Rev Time 0.00
Received By rmcdouga Date 2016-06-15 Time 14:31 Sent To  
Notes
2016-06-15 14:01:31PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT TWO SETS OF FLOOR PLANS OF THE SINGLE FAMILY
 RESIDENTIAL STRUCTURE SHOWING THE LOCATIONS OF THE
 PROPOSED WORK. FBC 107.2.1
  
 2) PROVIDE TWO COPIES OF A ROOF FRAMING PLAN AND
 SPECIFY WHICH TRUSSES WILL BE RETROFITTED WITH NEW
 HURRICANE STRAPS. FBC 107.2.1
  
 3) PROVIDE ENGINEERED DESIGN FOR ROOF TO WALL TRUSS
 CONNECTIONS OR COMPLY WITH THE PRESCRIPTIVE RETROFIT
 SOLUTIONS PROVIDED IN FBC EXISTING BUILDINGS SECTIONS
 708.8.1.1 THROUGH 708.8.1.7.
  
 4) SHOW COMPLIANCE WITH FBC-R314 FOR SMOKE ALARMS AND
 R-315 FOR CARBON MONOXIDE ALARMS.
  
 5) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS.
 ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF
 THE PERSON RESPONSIBLE FOR THE DESIGN.
  
 6) SUBMIT TWO COPIES OF THE MANUFACTURER'S
 SPECIFICATIONS AND INSTALLATION INSTRUCTIONS FOR THE
 NEW FIREPLACE. FBC 107.2.1
  
 7) THERE ARE TWO ELECTRICAL SUB PERMIT APPLICATIONS
 (#16050521 & #16051023) FROM DIFFERENT CONTRACTORS FOR
 THE ELECTRICAL WORK ON THIS PROJECT. THERE CAN ONLY BE
 ONE ELECTRICAL SUB FOR THIS SCOPE OF WORK. CHOOSE THE
 ONE YOU WILL USE AND CANCEL THE OTHER PERMIT.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-07-02 Cont ID  
Sent By vperez Date 2016-07-02 Time 11:35 Rev Time 0.00
Received By vperez Date 2016-07-02 Time 11:19 Sent To  
Notes
2016-07-02 11:35:21INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA RES BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011 NEC
 COMMENTS:
  
 1. PROVISO- AT FINAL PROVIDE NEW PANEL SCHEDULE AND
 CALCS FOR NEW LOADS. VERIFY EXISTING SMOKE DETECTORS
 2. PLEASE FEEL FREE TO CONTACT ME SHOULD YOU HAVE ANY
 QUESTIONS REGARDING THIS PROJECT.
  
  
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-05-20 Cont ID  
Sent By vperez Date 2016-05-20 Time 16:12 Rev Time 0.00
Received By vperez Date 2016-05-20 Time 16:12 Sent To  
Notes
2016-06-15 14:44:08TWO ELECTRICAL APPLICATIONS ARE PROVIDED. ASSURE THAT
 ONE IS NOT SUPERFLUOUS.
  
2016-05-20 16:14:46INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 EXISTING FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011 NEC
 COMMENTS:
  
 1. PLEASE PROVIDE A FLOOR PLAN REFLECTING ELECTRICAL
 SCOPE OF WORK FOR A COMPLETE REVIEW. FBC 107.3.5
 MINIMUM PLAN REVIEW.
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-07-05 Cont ID  
Sent By rmcdouga Date 2016-07-05 Time 13:47 Rev Time 0.00
Received By rmcdouga Date 2016-06-21 Time 15:28 Sent To  
Notes
2016-06-21 15:28:08R04

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-06-15 Cont ID  
Sent By rmcdouga Date 2016-06-15 Time 14:32 Rev Time 0.00
Received By rmcdouga Date 2016-05-12 Time 11:44 Sent To  
Notes
2016-05-13 11:44:56R12

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-07-05 Cont ID  
Sent By rmcdouga Date 2016-07-05 Time 13:47 Rev Time 0.00
Received By rmcdouga Date 2016-07-05 Time 13:47 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-05-16 Cont ID  
Sent By gjohnson Date 2016-05-16 Time 17:52 Rev Time 0.00
Received By gjohnson Date 2016-05-16 Time 17:52 Sent To  
Notes
2016-05-16 17:55:451ST REVIEW: FBC 2014
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. PROVIDE FLOOR PLAN SHOWING EXISTING LOCATIONS OF
 FIXTURE AND NEW LOCATION OF TUB IN MASTER. PER WPB
 AMEND. TO FBC 107.2.1


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved