Plan Review Details - Permit 16050501
Plan Review Stops For Permit 16050501
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-05-27 Cont ID  
Sent By shill Date 2016-05-27 Time 09:52 Rev Time 0.00
Received By shill Date 2016-05-27 Time 09:52 Sent To  
Notes
2016-05-27 09:54:38****PROVISO****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FLOORING TO BE TILE (NOT WOOD AS SPECIFIED ON THE PLAN)
 PER CONTRACTOR.
  
 CONTRACTOR TO PROVIDE A LETTER FROM THE ENGINEER AT
 INSPECTION.
  
 (SUPER SAM 125 TEST REPORTS WERE SENT VIA EMAIL TO
 FILENET)
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-05-24 Cont ID  
Sent By shill Date 2016-05-24 Time 16:15 Rev Time 0.00
Received By shill Date 2016-05-24 Time 16:15 Sent To  
Notes
2016-05-24 16:21:56****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
 [email protected]
  
 FBC FLORIDA BUILDING CODE 5TH EDITION 2014
  
 TWO COMPLETE COLLATED SETS OF ALL DOCUMENTS REQUIRED
  
 PLEASE NOTE THAT TEST REPORTS ARE REQUIRED -
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
  
 1. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.
 IF A SUSPENDED CEILING WAS USED AS A PART OF THE TEST,
 PROVIDE INFORMATION AS TO HOW IT HAS BEEN DETERMINED
 THAT THIS CONDITION CURRENTLY EXISTS AND HOW IT CAN BE
 GUARANTEED THAT THE CONDITIONS IN THE UNIT BELOW WILL
 NOT BE ALTERED.
  
 PLEASE PROVIDE A COPY OF THE TEST REPORT.
  
 2. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. IF A SUSPENDED CEILING WAS USED AS A PART
 OF THE TEST, PROVIDE INFORMATION AS TO HOW IT HAS BEEN
 DETERMINED THAT THIS CONDITION CURRENTLY EXISTS AND HOW
 IT CAN BE GUARANTEED THAT THE CONDITIONS IN THE UNIT
 BELOW WILL NOT BE ALTERED.
  
 PLEASE PROVIDE A COPY OF THE TEST REPORT.
  
 3. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 SEE 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM
 E 84 OR UL 723. AS WOOD FLOORING IS PROPOSED, THE FLAME
 SPREAD TEST SHOULD NOT INCLUDE TILE.
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-05-20 Cont ID  
Sent By vperez Date 2016-05-20 Time 14:44 Rev Time 0.00
Received By vperez Date 2016-05-20 Time 14:44 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2016-05-18 Cont ID  
Sent By pleduc Date 2016-05-18 Time   Rev Time 0.00
Received By pleduc Date 2016-05-16 Time 16:56 Sent To  
Notes
2016-05-18 10:07:52THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
 1) THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF
 THE SPRINKLER SYSTEM FOR CODE COVERAGE AND COMPLIANCE.
 ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS REQUIRE AN EVALUATION BY A CERTIFIED LIFE
 SAFETY CONTRACTOR.
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
 ANY AND ALL WORK ON THE FIRE SPRINKLER SYSTEMS SHALL BE
 DONE UNDER SEPARATE SHOP DRAWINGS AND BY CERTIFIED LIFE
 SAFETY CONTRACTORS.
 ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-05-27 Cont ID  
Sent By shill Date 2016-05-27 Time 09:54 Rev Time 0.00
Received By shill Date 2016-05-26 Time 14:38 Sent To  
Notes
2016-05-26 14:38:41TO SH DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-05-24 Cont ID  
Sent By shill Date 2016-05-24 Time 16:22 Rev Time 0.00
Received By shill Date 2016-05-12 Time 10:52 Sent To  
Notes
2016-05-13 10:52:26B04

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-05-23 Cont ID  
Sent By gjohnson Date 2016-05-23 Time 13:35 Rev Time 0.00
Received By gjohnson Date 2016-05-23 Time 13:35 Sent To  
Notes
***NONE***