| 2016-06-02 15:17:54 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6724 |
| | |
| | 1. SCOPE IS NOT CLEAR. THE SITE PLAN DOES NOT SHOW |
| | LOCATION OF PROPOSED RAILING. POOL BARRIER ENGINEERING |
| | WAS SUBMITTED. ONE COPY OF A CONTRACT FOR A BALCONY |
| | RAILING WAS SUBMITTED, APPLICATION STATES THIS IS A |
| | BALCONY RAILING. |
| | |
| | FBC 107, REVISE THE SITE PLAN TO SHOW LOCATION OF |
| | PROPOSED IMPROVEMENT, WITH DIMENSIONS. |
| | |
| | IF A FENCE OR POOL BARRIER IS PROPOSED (PLANS MAKE SOME |
| | REFERENCE TO BALCONY RAIL BUT ALL CODE REFERENCES ARE |
| | FOR RESIDENTIAL POOL BARRIER), PROVIDE EASEMENT CONSENT |
| | FOR FENCING PROPOSED IN UTILITYE EASEMENTS. |
| | |
| | IF A BALCONY RAILING IS PROPOSED, PROVIDE A PLAN WHICH |
| | SHOWS COMPLIANCE WITH FBC 5TH EDITION RESIDENTIAL 312 |
| | IF THIS IS GOVERNED BY FBC 5TH ED RESIDENTIAL, OR BY |
| | FBC 5TH EDITION BUILDING 1013 AND 1607.8 IF FBC 5TH |
| | EDITION BUILDING APPLIES (SEE OTHER COMMENTS). |
| | |
| | 2. NOTE 8, THE PLAN STATES THAT RAILING COMPLIES WITH |
| | POOL BARRIER REQUIREMENTS AND ALSO REFERS TO FBC R |
| | 5101.17. SINCE THE LAST CHAPTER IN THE FBC 5TH EDITION |
| | RESIDENTIAL IS CHAPTER 46, THE PURPOSE OF THAT |
| | STATEMENT IS NOT CLEAR. |
| | |
| | 3. OCCUPANCY CLASSIFICATION IS NOT CLEAR. ALL |
| | REFERENCES ON THE PLANS ARE FOR FBC 5TH EDITION |
| | RESIDENTIAL POOL BARRIERS AND BROWARD COUNTY FENCING. |
| | SEE BUILDING PERMIT 14110788 FOR THIS BUILDING. THE |
| | DESIGN PROFESSIONAL GIVES THIS BUILDING AN OCCUPANCY |
| | CLASSIFICATION OF R2. IF THIS IS A BALCONY RAILING FOR |
| | R2, NOTE THAT NONE OF THE CODE REFERENCES ARE FOR FBC |
| | 5TH EDITION BUILDING. THE PLANS ARE TO SHOW COMPLIANCE, |
| | PER FBC 107 CANNOT REFER TO CODE SECTIONS ONLY TO |
| | DEMONSTRATE COMPLIANCE. THE DESIGN CRITERIA IS TO BE |
| | STATED ON THE PLAN. |
| | |
| | 4. CLARIFY ANCHOR SPECIFICATION. NO MINIMUM CONCRETE |
| | STRENGTH OR ANCHOR CAPACITY WAS STATED, MATERIAL FOR |
| | "CONCRETE SCREW", TYPE OF SCREW NOT SPECIFIED, FBC 107. |