Plan Review Details - Permit 16050356
Plan Review Stops For Permit 16050356
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-06-02 Cont ID  
Sent By jgomez Date 2016-06-02 Time 13:52 Rev Time 0.00
Received By jgomez Date 2016-06-02 Time 17:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-05-09 Cont ID  
Sent By jgomez Date 2016-05-09 Time 15:40 Rev Time 0.00
Received By jgomez Date 2016-05-09 Time 15:40 Sent To  
Notes
2016-05-09 15:40:29RESIDENTIAL (R3) BUILDING REVISION COMMENTS.
 CODE: FBC 5TH EDITION (2014)
  
 NOTE: THE REVISION FEE IS $207. THE ARCHITECTURAL
 DRAWINGS SUBMITTED ARE APPROVED. THE ENERGY
 CALCULATIONS NEED TO BE REVISED. REMAINDER: PROVIDE ALL
 OTHER ITEMS REQUESTED ON PROVISO. SEE ORIGINAL APPROVED
 PLANS.
  
 1- REVISE ENERGY CALCULATIONS SUBMITTED:
 A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM
 INCLUDING THE BUILDER NAME, CORRECT PERMIT OFFICE (1212
 FLORIDA AVE IS NOT THE PERMIT OFFICE). SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014)
  
 B) ADJACENT WALL TYPE AND INSULATION R-VALUE ON ITEM #9
 IS INCORRECT. SEE PLANS AND REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014)
  
 C) REVISE THE WINDOWS OVERHANG SEPARATION TO MATCH
 PLANS. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH
 EDITION (2014)
  
  
 IMPORTANT: LABEL FOR WINDOWS AND DOORS SHOWING THE
 U-FACTOR AND SHGC FACTOR SPECIFIED ON THE ENERGY
 CALCULATIONS WILL BE REQUIRED WHEN ENERGY CALCULATIONS
 ARE NOT USING THE SOFTWARE DEFAULT FACTOR FOR GLAZING.
  
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2016-06-01 Cont ID  
Sent By fmittner Date 2016-06-01 Time 11:33 Rev Time 0.00
Received By fmittner Date 2016-06-01 Time 11:33 Sent To  
Notes
2016-06-01 11:34:07VINYL PRODUCT APPROVED BY HPB DUE TO NEW CONSTRUCTION

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-06-02 Cont ID  
Sent By jgomez Date 2016-06-02 Time 13:52 Rev Time 0.00
Received By jgomez Date 2016-05-27 Time 11:10 Sent To  
Notes
2016-05-27 11:12:38PRODUCT APPROVALS REVISION SENT TO ZONING SHELF FOR
 FRIEDERIKE MITTNER'S REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-05-09 Cont ID  
Sent By jgomez Date 2016-05-09 Time 16:27 Rev Time 0.00
Received By jgomez Date 2016-05-02 Time 15:40 Sent To  
Notes
***NONE***