| Plan Review Stops For Permit 16050233 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-06-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-06-24 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-06-24 |
Time |
07:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-06-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-06-07 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-06-07 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2016-06-07 07:43:21 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16050233 | | | ADD: 1401 FORUM WAY SUITE: 810 | | | CONT: TBD/ TO BE DETERMINED | | | TEL: 561-833-0164 | | | E-MAIL: | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: TUES. JUNE 07/2016 | | | ACTION: DENIED | | | | | | 1-2) COMPLIED. | | | | | | 3) RESPONSE INDICATES NOTED, BUT THE NEW SHEETS WERE | | | NOT INSERTED INTO THE PLAN REVIEW SET OF PLANS AND OLD | | | SHEETS REMOVED AS REQUESTED, THIS IS THE CONTRACTORS | | | RESPONSIBILITY!!!!! | | | 1ST REVIEW COMMENT.WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE ANY VOIDED SHEETS & | | | REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A | | | DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-05-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-05-13 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-05-13 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2016-05-13 17:17:33 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16050233 | | | ADD: 1401 FORUM WAY SUITE: 810 | | | CONT: TBD/ TO BE DETERMINED | | | TEL: 561-833-0164 | | | E-MAIL: | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: FRI. MAY 13/2016 | | | ACTION: DENIED | | | | | | 1) SHEET A-1.0 INDICATES THE USE OF 2 4X4 FIRE | | | RETARDANT TREATED POST FOR SUPPORTING OF X-RAY | | | EQUIPMENT. THE PLANS ARE DEFICIENT IN HOW THE POST ARE | | | TO BE ANCHORED TO THE CONCRETE FLOOR SLAB AND TO THE | | | CONCRETE FLOOR SYSTEM ABOVE? IS THIS BUILDING A | | | POST-STRESSED CABLE FLOOR SYSTEM OR A CONVENTIONAL | | | SLAB? 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 2) SHEET A-1.0 DOES NOT PROVIDE INFORMATION INREGAURDS | | | TO ACCESSIBILITY; | | | 2A) 2014 FBC-ACCESSIBILITY CODE 606.3 HEIGHT. | | | LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT | | | OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES | | | (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 2B) 2014 ACCESS. CODE 904.3.3 CHECK WRITING SURFACES. | | | WHERE PROVIDED, CHECK WRITING SURFACES SHALL COMPLY | | | WITH 902.3 | | | 902.3 HEIGHT. THE TOPS OF WORK SURFACES SHALL BE 28 | | | INCHES (710 MM) MINIMUM AND 34 INCHES (865 MM) MAXIMUM | | | ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2016-06-27 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-06-27 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-06-27 |
Time |
14:40 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2016-06-15 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-06-15 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-06-15 |
Time |
08:20 |
Sent To |
|
|
| Notes |
| 2016-06-15 08:49:31 | 2ND REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | | | | - PLEASE PROVIDE X-RAY EQUIPMENT MANUFACTURE | | | SPECIFICATION CUT SHEETS ( 2ND REQUEST ) | | | | | | - LOAD CALCS AND PANEL SCHEDULE REFLECT SINGLE PHASE | | | VOLTAGE AND RISER DIAGRAM SHOWS THREE PHASE ? PLEASE | | | CLARIFY AND MATCH INFORMATION. ( 2ND REQUEST ) |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-05-12 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-05-12 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-05-12 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2016-05-12 12:55:24 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 NEC | | | COMMENTS: | | | | | | 1. PLEASE PROVIDE A GENERAL NOTE TO INDICATE NEC 517.13 | | | SEE VERBIAGE IN CODE FOR REDUNDANT GROUNDING AND PART V | | | OF THE NEC 517 REGARDING X-RAY EQUIPMENT. | | | 2. PROVIDE SPECS OF X-RAY EQUIPMENT BEING INSTALLED. | | | FBC 107.3.5 | | | 3. CLARIFY IF THE VOLTAGE TO TENANT IS SINGLE PHASE OR | | | 3 PHASE. SEE PANEL SCHEDULE SHOWS SINGLE PHASE BUT | | | VACUUM PUMP AND AIR COMP. EQUIPMENT IS SHOWN ON A | | | SINGLE BREAKER 230VOLTS. PLEASE CORRECT TO SHOW | | | ADEQUATE LOADS AND VOLTAGES. FBC 107.3.5 | | | 4. ALL RECEPTACLES WITHIN 6FT OF SINKS TO HAVE GFCI | | | PROTECTION, LABEL FLOOR PLANS SEE WORK AREA AND DENTAL | | | CHAIRS. NEC 210.8B7 | | | 5. FURTHER COMMENTS MAY FOLLOW UPON RESUBMITTAL. PLEASE | | | FEEL FREE TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS | | | REGARDING THIS PROJECT. | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2016-06-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-06-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-06-24 |
Time |
14:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2016-05-31 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-05-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-05-31 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2016-05-31 15:36:45 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) FIRE COULD NOT PASS AND STAMP THESE SUBMITTED PLANS. | | | | | | A. THE PLANS WERE NOT COLLATED. THE NEW SHEETS SHALL BE | | | INSERTED WERE APPROPRIATE AND SECURED. | | | | | | B. THE NEW SHEETS DID NOT MATCH ADDRESSES, TITLE BLOCK | | | AND SHEET NUMBERS. | | | | | | 2) PLEASE REVIEW AND ENSURE THE ABOVE NOTED POINTS ARE | | | CORRECTED AND RESUBMITTED. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2016-05-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-05-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-05-09 |
Time |
15:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-06-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-06-28 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-06-21 |
Time |
08:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-06-15 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-06-15 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-05-27 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-05-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-05-13 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-05-05 |
Time |
14:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2016-06-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-06-24 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-06-24 |
Time |
16:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-06-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-06-02 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-06-02 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2016-06-02 15:03:09 | 2ND REVIEW: FBC 2014 MECHANICAL, EXISTING | | | PERMIT #16050233 | | | 5/11/2016 | | | | | | COMMENTS #1, & 2B FROM THE 1ST REVIEW STILL EXIST. I | | | HAVE RE-PRINTED THEM BELOW. PLEASE REVIEW AND REVISE | | | THE PLAN ACCORDINGLY. | | | | | | 1) REFER TO SECTION 809.2 FBC-14 EXISTING BUILDING, AND | | | PROVIDE MINIMUM VENTILATION CALCULATIONS FOR THE | | | PROPOSED OCCUPANCY IN COMPLIANCE WITH TABLE 403.3 | | | FBC-14 MECHANICAL. | | | 2 B) PROVIDE THE SUPPLY AND RETURN CFM'S AT EACH | | | DIFFUSER AND GRILL. | | | 3) RETURN AIR FROM THE EQUIPMENT CLOSET IS PROHIBITED | | | PER SECTION 918.6 MECHANICAL. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-05-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-05-11 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-05-11 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2016-05-11 10:17:03 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #16050233 | | | 5/11/2016 | | | | | | 1) REFER TO SECTION 809.2 FBC-14 EXISTING BUILDING, AND | | | PROVIDE MINIMUM VENTILATION CALCULATIONS FOR THE | | | PROPOSED OCCUPANCY IN COMPLIANCE WITH TABLE 403.3 | | | FBC-14 MECHANICAL. | | | 2) SHEET MEP-2: THE HVAC PLAN IS INCOMPLETE: A) LABEL | | | ALL DIFFUSERS AND RETURN GRILLS AS EITHER NEW (N), | | | EXISTING (E), OR RELOCATED (R). B) PROVIDE THE SUPPLY | | | AND RETURN CFM'S AT EACH DIFFUSER AND GRILL. C) SHOW | | | NEW DUCT INSTALLATIONS OR RELOCATIONS. | | | 3) PROVIDE AN AIR DEVICE SCHEDULE. | | | 4) PROVIDE DUCT HANGING AND CONNECTION DETAILS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2016-06-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-06-28 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-06-28 |
Time |
15:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2016-06-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2016-06-13 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-05-11 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-05-11 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-05-11 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2016-05-11 11:55:06 | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1.DRAIN NOT SHOWN FOR EXAM ROOM 3 PLEASE CLARIFY . PER | | | WPB AMEND TO FBC SEC. 107.2.1 | | | | | | 2.DRAIN NOT SHOWN FOR BREAKROOM /FUTURE EXAM PLEASE | | | CLARIFY. PER WPB AMEND TO FBC SEC. 107.2.1 | | | | | | 3. A VENT IS REQUIRED ON 2IN DRAIN FOR EXAM CHAIRS. PER | | | FBC PL SEC. 901.2.1 | | | | | | 4. PROVIDE A RISER DIAGRAM FOR THE WATER, VACUUM AND | | | COMPRESSED AIR SYSTEMS. PER WPB AMEND. TO FBC SEC. | | | 107.3.5.1.3(13) | | | | | | 5.SHOW VACUUM AND COMPRESSED AIR ON PLAN VIEW. PER WPB | | | AMEND TO FBC SEC. 107.2.1 | | | | | | 6. PROVIDE MANUFACTURE SPECS ON ALL EQUIPMENT. PER WPB | | | AMEND TO FBC SEC. 107.2.1 | | | | | | 7. SHOW VENTING FOR VACUUM SYSTEM. SHALL COMPLY WITH | | | FBC PL 713.6 | | | | | | 8. BACK FLOW DEVICE REQUIRED FOR EXAM CHAIR WATER | | | CONNECTION. PER FBC PL SEC. 608.3.1 | | | | | | 9. IF THE VACUUM SYSTEM REQUIRES A DRAIN INCLUDE IT ON | | | THE PLAN VIEW AND SANITARY RISER. PER WPB AMEND TO FBC | | | SEC. 107.2.1 | | | |
|
|