| Plan Review Stops For Permit 16050022 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2017-05-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-05-17 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-05-17 |
Time |
14:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2017-05-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-05-15 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-05-11 |
Time |
19:12 |
Sent To |
|
|
| Notes |
| 2017-05-15 14:30:08 | THE OWNER/AGENT IS REQUIRED TO SIGN AND DATE THE ENERGY | | | FORM R405. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2017-04-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-04-26 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-04-26 |
Time |
06:56 |
Sent To |
|
|
| Notes |
| 2017-04-26 11:49:41 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. THE PRODUCT APPROVALS ARE REQUIRED TO BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD. | | | | | | 2) ON THE ENERGY FORM R405-2014, THE NUMBERS FOR THE | | | COOLING BTUS AND THE SEER ARE SWITCHED. THE SEER SHOULD | | | BE 16 AND THE BTUS SHOULD BE 18,000. FBC 107.2.1 | | | | | | 3) THE AHRI CERTIFICATION LETTER DOES NOT MATCH THE | | | MODELS SPECIFIED ON THE PLANS. FBC 107.2.1 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-09-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-09-07 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-09-06 |
Time |
18:27 |
Sent To |
|
|
| Notes |
| 2016-09-06 18:58:28 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT TWO SETS OF ENERGY CODE COMPLIANCE FORMS THAT | | | HAVE THE SIGNATURES OF THE PREPARER AND THE | | | OWNER/AGENT. FBC ENERGY CONSERVATION R103 - COMPLETED | | | FORMS R402 OR R405 ARE ACCEPTABLE. | | | | | | 2) PROVIDE SIGNED AND SEALED CALCULATIONS TO VERIFY | | | THAT THE (2) 2 X 12 BEAM SPANNING 15 FEET CAN SUPPORT | | | THE 40 PSF LIVE LOAD AND DEAD LOAD OF THE BALCONY. FBC | | | 107.2.1.3 | | | | | | 3) THE PLANS DO NOT SPECIFY ANY CROSS BRACING OF THE | | | DECK OR THE 4 X 4 POSTS THAT ARE SUPPORTING THE DECK. | | | PROVIDE SIGNED AND SEALED CALCULATIONS TO SHOW THAT THE | | | 4" X 4" X 8' WOOD POSTS ARE CAPABLE OF RESISTING THE | | | LATERAL LOADS, WIND LOADS, ETC. | | | | | | 4) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 | | | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT | | | APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION | | | INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR THE RIDGE | | | OR ROOF VENT, THE SIDING (IF IT IS ALUMINUM OR VINYL) | | | AND THE ALUMINUM SOFFIT MATERIAL. | | | | | | 5) THE PRODUCT APPROVAL THAT WAS SUBMITTED FOR THE | | | SINGLE OUTSWING DOOR HAS A MAXIMUM NEGATIVE DESIGN | | | PRESSURE FOR THE DOOR OF (-50 PSF) IS NOT ADEQUATE FOR | | | THE DOOR LOCATED ON THE FIRST FLOOR IN THE END ZONE, | | | WHICH REQUIRES -54.8 PSF. SUBMIT CORRECT PRODUCT | | | APPROVALS. FBC-R301.2.1 | | | | | | 6) THE PRODUCT APPROVAL THAT WAS SUBMITTED FOR THE | | | SECTIONAL GARAGE DOOR HAS MAXIMUM DESIGN PRESSURES OF | | | +36, -42.5 PSF WHICH ARE NOT ADEQUATE. THE PLANS | | | SPECIFY THAT THE REQUIRED PRESSURES ARE +37.5, -42.5 | | | PSF. SUBMIT CORRECT PRODUCT APPROVALS. FBC-R301.2.1 | | | | | | 7) SUBMIT TWO COPIES OF THE PRODUCT EVALUATION REPORTS | | | WITH INSTALLATION REQUIREMENTS FOR THE OPEN CELL SPRAY | | | FOAM INSULATION THAT IS SPECIFIED ON THE PLANS. FBC | | | R316 | | | | | | 8) THE SECOND FLOOR OF THIS STRUCTURE IS CONDITIONED | | | SPACE. THE FLOOR/CEILING ASSEMBLY ABOVE THE GARAGE IS | | | REQUIRED TO HAVE THERMAL INSULATION. FBC ENERGY | | | CONSERVATION R402.1 | | | | | | 9) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A | | | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-06-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-06-28 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-06-24 |
Time |
18:56 |
Sent To |
|
|
| Notes |
| 2016-06-28 13:56:54 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT TWO SETS OF ENERGY CODE COMPLIANCE FORMS THAT | | | HAVE THE SIGNATURES OF THE PREPARER AND THE | | | OWNER/AGENT. FBC ENERGY CONSERVATION R103 | | | | | | 2) THERE ARE SEVERAL ERRORS ON SHEET 2 OF THE PLANS. | | | THERE IS A WALL SECTION MARKER (1 ON 5) SHOWN IN THE | | | OPEN AREA IN THE GARAGE. THE TYPE OF CONSTRUCTION IS | | | V-B AND THE OCCUPANCY TYPE IS R-3, SINGLE FAMILY | | | DWELLING. FBC 310.5 | | | | | | 3) SHOW COMPLIANCE WITH FBC-R311.7.8 FOR REQUIRED | | | HANDRAILS AND FBC-R311.7.8.1 FOR HANDRAIL HEIGHT. | | | | | | 4) SPECIFY THE REQUIRED LIVE LOADS FOR THE DWELLING AND | | | BALCONY FLOORS AND THE STAIRS ON THE PLANS. FBC R301.5 | | | | | | 5) NONE OF THE WINDOWS ON THE SECOND FLOOR MEET THE | | | EMERGENCY ESCAPE AND RESCUE REQUIREMENTS OF FBC-R310 | | | FOR SLEEPING ROOMS. THE STORAGE AREA CAN NOT BE USED | | | FOR SLEEPING UNLESS THERE IS A WINDOW THAT COMPLIES | | | WITH FBC-R310. | | | | | | 6) PROVIDE CALCULATIONS TO VERIFY THAT THE (2) 2 X 12 | | | BEAM SPANNING 15 FEET CAN SUPPORT THE 40 PSF LIVE LOAD | | | AND DEAD LOAD OF THE BALCONY. FBC 107.2.1.3 | | | | | | 7) THE SECOND FLOOR OF THIS STRUCTURE IS CONDITIONED | | | SPACE. THE FLOOR/CEILING ASSEMBLY ABOVE THE GARAGE IS | | | REQUIRED TO HAVE THERMAL INSULATION. FBC ENERGY | | | CONSERVATION R402.1 | | | | | | 8) THE SECOND FLOOR DWELLING AREA IS REQUIRED TO BE | | | SEPARATED FROM THE GARAGE BY 5/8" TYPE X DRYWALL OR | | | EQUIVALENT PER FBC-R302.6 AND TABLE 302.6. | | | | | | 9) FBC-R302.5 REQUIRES OPENINGS IN THE GARAGE CEILING | | | TO BE PROTECTED IN ACCORDANCE WITH FBC-R302.11(4). | | | | | | 10) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 | | | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT | | | APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION | | | INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR THE | | | DIFFERENT RIDGE OR ROOF VENT, THE SIDING AND THE | | | ALUMINUM SOFFIT MATERIAL. | | | | | | 11) THE PRODUCT APPROVAL THAT WAS SUBMITTED IS FOR A | | | DOUBLE OUTSWING DOOR AND THE PLANS SPECIFY A SINGLE | | | OUTSWING DOOR. THE MAXIMUM NEGATIVE DESIGN PRESSURE FOR | | | THE DOOR (-50 PSF) IS NOT ADEQUATE FOR THE DOOR LOCATED | | | ON THE FIRST FLOOR IN EDGE ZONE 5, WHICH REQUIRES -54.8 | | | PSF. SUBMIT CORRECT PRODUCT APPROVALS. FBC-R301.2.1 | | | | | | 12) SUBMIT TWO SETS OF SURFACE WATER DRAINAGE PLANS | | | THAT SHOW COMPLIANCE WITH FBC-R401.3. | | | | | | 13) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT | | | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2017-03-28 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-03-28 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-03-28 |
Time |
12:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-08-12 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-08-12 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-08-12 |
Time |
08:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-05-13 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-05-13 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-05-13 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2016-05-13 11:55:56 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA RES BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 | | | COMMENTS: | | | | | | 1. SHOW A SMOKE DETECTOR AT THE LANDING AREA OF STAIRS | | | AND THROUGHOUT PER FBC RES 314 & 315. | | | 2. GENERAL NOTE TO INDICATED REQUIRED SEPARATE PERMITS | | | FOR LOW VOLTAGE SYSTEMS. | | | 3. PANEL BOARD MUST BE AT THE NEW DETACHED STRUCTURE | | | AND A GROUNDING ELECTRODE CONDUCTOR MUST BE SHOWN PER | | | E3607.3. SHOW PANEL LOCATION ON FLOOR PLAN OF DETACHED. | | | 4. PLEASE SHOW THE FEEDER CONDUCTOR SIZES AND EQUIPMENT | | | GROUNDING CONDUCTOR REQUIRED WITH THESE FEEDERS. FBC | | | 107.3.5 | | | 5. PROVIDE PANEL SCHEDULE ON SHEET 6 OF THIS STRUCTURE. | | | FBC 107.3.5 | | | 6. PROVIDE GENERAL NOTES TO INDICATE REQUIREMENTS FOR | | | AFCI PROTECTION, TAMPER RESISTANT RECEPTACLES. FBC RES | | | E3902 E4002.14 | | | 7. GARAGE DOOR OPENER TO BE LABELED GFCI PROTECTED PER | | | FBC RES E3902.2 | | | 8. FEEL FREE TO CONTACT ME SHOULD YOU HAVE ANY | | | QUESTIONS OR CONCERNS. | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2016-09-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-09-20 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-08-26 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2016-08-26 10:02:44 | GAS PLAN REVIEW | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | | GAS SEC. 301.3. | | | | | | A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION | | | | | | GAS PERMIT APPLICATION REQUIREMENTS | | | | | | EFFECTIVE IMMEDIATELY THE FOLLOWING INFORMATION SHALL | | | BE SHOWN ON ALL GAS DRAWINGS SUBMITTED FOR PERMITTING | | | IN THE CITY OF WEST PALM BEACH: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER | | | FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS | | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB | | | AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | 3. TYPE OF GAS, (LP OR NATURAL). | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON | | | THE SYSTEM. REFER TO THE FBC-2014 FUEL GAS SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU 402.4(37). | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | | AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ? | | | USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE | | | SEC. 402.4.1. | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2014 | | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | | PSI. | | | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | | SEC. 502 THRU 505. | | | | | | 9. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2017-05-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-05-15 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2017-05-11 |
Time |
09:09 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-04-05 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2017-04-05 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2017-04-05 |
Time |
09:32 |
Sent To |
B |
|
| Notes |
| 2017-04-05 09:33:18 | 4/5/2017 - REVISIONS STILL MEET HPB APPROVED PLANS. DLE |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-09-13 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2016-09-13 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2016-09-13 |
Time |
13:21 |
Sent To |
B |
|
| Notes |
| 2016-09-13 13:22:47 | 9/13/16 - SCOPE OF WORK UNCHANGED SINCE HPB APPROVAL | | | CASE NO.16-18 (APRIL 2016). DLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2017-05-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-05-15 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-05-05 |
Time |
16:26 |
Sent To |
HIST |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2017-04-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-04-26 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-03-24 |
Time |
15:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-09-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-09-20 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-09-16 |
Time |
12:31 |
Sent To |
|
|
| Notes |
| 2016-09-16 12:31:47 | ROUTED TO JORGE VALIDO |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-09-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-09-20 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-08-05 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2016-09-16 17:32:15 | ROUTED TO GEORGE JOHNSON 9/16/2016 JDV | | 2016-08-08 12:54:14 | R22 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-08-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-06-28 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2016-06-28 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2016-05-03 09:22:45 | R07 - TRAVELING WITH 16050027 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2017-05-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-05-17 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-05-17 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2017-05-17 14:38:53 | MU 2017-13640 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2017-05-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-05-11 |
Time |
19:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-05-11 |
Time |
19:12 |
Sent To |
|
|
| Notes |
| 2017-05-11 19:13:46 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2016-09-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-09-06 |
Time |
18:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-09-06 |
Time |
18:27 |
Sent To |
|
|
| Notes |
| 2016-09-06 18:28:08 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2016-06-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-06-24 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-06-24 |
Time |
18:57 |
Sent To |
|
|
| Notes |
| 2016-06-24 18:57:47 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-04-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-04-21 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-04-20 |
Time |
16:13 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-09-16 |
|
|
Cont ID |
|
| Sent By |
jvalido |
Date |
2016-09-16 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
jvalido |
Date |
2016-09-16 |
Time |
17:24 |
Sent To |
|
|
| Notes |
| 2016-09-16 17:31:22 | CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA | | | BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION | | | | | | 107.1 GENERAL ? 107.2 CONSTRUCTION DOCUMENTS ? 107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENT | | | | | | (1) PROVIDE LOCATION OF CONDENSER ON PLANS. | | | | | | FLORIDA ENERGY CODE FBC 2014 | | | | | | (2) FORM R405 - 2014 ENERGY CALCULATIONS REQUIRED | | | (3) HEATLOAD CALCULATIONS REQUIRED. | | | (4) AHRI IS REQUIRED FOR EQUIPMENT SPECIFIED ON PLANS. | | | | | | (3) PROVIDE AHRI FOR EQUIPMENT SPECIFIED ON PLANS. | | | | | | JORGE VALIDO | | | WPB MECHANICAL INSPECTOR/PLANS EXAMINER | | | [email protected] | | | 561-805-6716 | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-06-07 |
|
|
Cont ID |
|
| Sent By |
jvalido |
Date |
2016-06-07 |
Time |
19:07 |
Rev Time |
0.00 |
| Received By |
jvalido |
Date |
2016-06-07 |
Time |
19:03 |
Sent To |
|
|
| Notes |
| 2016-06-07 19:07:28 | CITY OF WEST PALM BEACH LOCAL AMENDMENTS TO THE FLORIDA | | | BUILDING CODE (FBC) 2010 CHAPTER 1 ADMINISTRATION | | | | | | 107.1 GENERAL - 107.2 CONSTRUCTION DOCUMENTS - 107.2.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS | | | | | | PROVIDE MECHANICAL PLANS FOR LOFT. | | | | | | FLORIDA ENERGY CODE - FBC 2014 | | | | | | (2) PROVIDE ENERGY CALCULATIONS | | | (3) PROVIDE HEAT LOAD CALCULATIONS | | | (4) PROVIDE AHRI | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2017-04-14 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-04-14 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-04-14 |
Time |
11:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-08-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-08-26 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-08-25 |
Time |
13:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-06-30 |
|
|
Cont ID |
|
| Sent By |
gearl |
Date |
2016-06-30 |
Time |
06:33 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-06-30 |
Time |
06:30 |
Sent To |
|
|
| Notes |
| 2016-05-05 12:16:23 | | | | | | | | | | | | | PLANS SHOW FUTURE BATHROOM | | | | | | GEORGE EARL PLUMBING PLANS REVIEWER 0013 B |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2017-04-19 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2017-04-19 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2017-04-19 |
Time |
15:22 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2016-09-13 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2016-09-13 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2016-09-13 |
Time |
13:22 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-05-17 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2016-05-17 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2016-05-17 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2016-05-17 13:12:19 | 5/17/16 - HPD APPROVED PLANS AT APRIL 26 MEETING; | | | PROPOSED PLANS MATCH APPROVED CONDITIONS, AND DESIGN | | | MEETS LDR STANDARDS. DLE |
|
|