| Plan Review Stops For Permit 16041150 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-10-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-10-12 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-10-12 |
Time |
11:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-08-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-08-04 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-08-04 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2016-08-04 16:42:21 | | | | BUILDING PROVISO: | | | NOTE THIS POOL DECK AND POOL ARE COVERED UNDER THE FAIR | | | HOUSING ACT, TO DATE THE GUIDELINES ONLY REQUIRES | | | ACCESS MUST BE PROVIDED TO THE POOL DECK AREA, NOT AN | | | ACCESSIBLE ROUTE (RAMP OR LIFT) DOWN INTO THE WATER | | | INTO THE POOL. ON THE OTHER HAND IF THE ASSOCIATION | | | ELECTS TO ALLOW THE COMMUNITY ROOM, POOL, AND OR POOL | | | DECK TO BE RENTED OUT FOR PARTIES THAT THE PUBLIC COULD | | | USE, THEN THIS AREA WOULD BE REQUIRED TO MEET FLORIDA | | | ACCESSIBILITY SECTION 1009 OF THE ACCESSIBILITY CODE | | | POOL LIFTS. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-06-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-06-08 |
Time |
|
Rev Time |
|
| Received By |
jwitmer |
Date |
2016-06-08 |
Time |
|
Sent To |
E |
|
| Notes |
| 2016-06-08 14:42:48 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16041150 | | | ADD: 333 FERN ST/ POOL 7TH FLOOR LEVEL | | | CONT: A & G CONCRETE POOLS | | | TEL: 772-878-7752 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. JUNE 08/2016 | | | ACTION: DENIED | | | | | | NOTE: THIS REVIEW IT IS UNDERSTOOD THE PRIME BUILDING | | | PERMIT: 15031312 IS FOR A R-2 APARTMENT COMPLEX/ FAIR | | | HOUSING DOES NOT REQUIRE AN ACCESSIBLE ENTRANCE INTO | | | THE SWIMMING POOL. | | | | | | 1) THE SHEET 4 POOL EQUIPMENT ROOM LAYOUT SHOWS A | | | HEATER BUT THERE ARE NO MANUFACTURERS SPEC ON THE | | | HEATER. RESPONSE COMMENTS FROM ACE AQUATIC CONSULTING | | | COMMENT # 11 INDICATES THERE ARE MANUFACTURERS SPEC | | | SHEET ATTACHED TO THIS LETTER. NOT FOUND. THERE ARE | | | MANUFACTURER'S SPEC ON THE MAIN DRAIN GRATES. 107.2.1.3 | | | ADDITIONAL INFORMATION REQUIRED. SHOW COMPLIANCE WITH | | | 2014 FBC-ENERGY CODE | | | | | | 2) SHEET 4 SHOWING A HEATER WILL NEED TO SHOW | | | COMPLIANCE WITH: 2014 FBC-ENERGY CODE C404.7.1 POOL | | | HEATERS. | | | ALL POOL HEATERS SHALL MEET THE MINIMUM EFFICIENCY | | | LISTED FOR THAT TYPE OF POOL HEATER IN TABLE C404.2 AND | | | BE EQUIPPED WITH A READILY ACCESSIBLE ON-OFF SWITCH | | | THAT IS MOUNTED OUTSIDE OF THE HEATER TO ALLOW SHUTTING | | | OFF THE HEATER WITHOUT ADJUSTING THE THERMOSTAT | | | SETTING. GAS-FIRED HEATERS SHALL NOT BE EQUIPPED WITH | | | CONSTANT BURNING PILOT LIGHTS. | | | | | | 3) WITH THE SWIMMING POOL HAVING A HEATER PLEASE SHOW | | | COMPLIANCE WITH ENERGY CODE SECTION C404.7.3 COVERS. | | | HEATED SWIMMING POOLS AND INGROUND PERMANENTLY | | | INSTALLED SPAS SHALL BE EQUIPPED WITH A VAPOR-RETARDANT | | | COVER ON OR AT THE WATER SURFACE OR A LIQUID COVER OR | | | OTHER MEANS PROVEN TO REDUCE HEAT LOSS. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2016-09-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-10-12 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-09-21 |
Time |
14:17 |
Sent To |
P |
|
| Notes |
| 2016-09-21 15:26:53 | ROUTED TO TKL PLUMBING |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2016-07-27 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-07-27 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-07-27 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2016-07-27 10:34:10 | REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | | | | | | | | | | 1) OUTLETS SUPPLYING POOL PUMP MOTORS CONNECTED TO | | | SINGLE-PHASE, 120 VOLT THROUGH 240 VOLT BRANCH | | | CIRCUITS, RATED 15 OR 20 AMPERES, WHETHER BY RECEPTACLE | | | OR BY DIRECT CONNECTION, SHALL BE PROVIDED WITH | | | GROUND-FAULT CIRCUITINTERRUPTER PROTECTION FOR | | | PERSONNEL. | | | - SHOW GFCI PROTECTION ON THE ELECTRICAL DIAGRAM. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-06-20 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-06-20 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-06-20 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2016-06-20 08:56:06 | REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | - PROVIDE SPECS ON POOL EQUIPMENT POOL HEATERS AND POOL | | | PUMPS. FBC 107 INSUFFICIENT DOCUMENTS. | | | | | | - SPECIFY WHETHER LIGHT NICHE REQUIRES # 8 AWG BONDING | | | CONDUCTOR OR NOT ? NEC 680.22(B)(2)/680.24, IF NOT HOW | | | WILL POOL WATER BE BONDED ? NEC 680.26(C) | | | | | | - GENERAL COMMENT GFC PROTECTION REQUIRED FOR POOL | | | PUMPS , LIGHTS , RECEPTACLES. NEC 680.21, 680.22. | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2016-05-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-05-20 |
Time |
06:37 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-05-20 |
Time |
06:33 |
Sent To |
|
|
| Notes |
| 2016-05-20 06:36:57 | GAS PLAN REVIEW | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | | GAS SEC. 301.3. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-10-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-10-12 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-09-19 |
Time |
15:34 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-08-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-08-04 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-07-25 |
Time |
10:28 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-06-20 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-06-20 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-04-26 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2016-05-18 09:43:55 | ROUTED TO ELECTRIC. | | 2016-04-26 15:21:59 | ROUTED TO ZONING |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2016-09-24 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-09-24 |
Time |
04:30 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-09-24 |
Time |
03:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2016-07-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-08-04 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-07-26 |
Time |
06:13 |
Sent To |
|
|
| Notes |
| 2016-07-26 11:19:51 | SUBMIT MSDS ( MATERIAL SAFETY DATA SHEETS ) SHEETS FOR | | | THE POOL CHEMICALS THAT WILL BE USED IN TREATING THE | | | POOL WATER.WPB AMEND. TO FBC SEC. 107.2.1. 2ND REQUEST. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-05-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-05-20 |
Time |
06:33 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-05-19 |
Time |
06:21 |
Sent To |
|
|
| Notes |
| 2016-05-20 06:33:25 | 1) THE PLANS SHOW THE POOL WATER WASTE DISCHARGE TO THE | | | SANITARY SEWER.POOL WATER CANNOT DISCHARGE TO THE | | | SANITARY OR STORM SYSTEM PER WPB CITY ORD. SECS. 90-126 | | | (5), 90-203 (A), 90-204, AND 90-205 (1). THE RESPONSE | | | FROM THE ENGINEER OF RECORD STATES THAT THIS ISSUE HAS | | | BEEN RESOLVED AND THE WASTE WATER WILL GO TO THE | | | SANITARY. I DO NOT HAVE ANY DOCUMENTATION THAT THIS | | | WILL BE ALLOWED. | | | 2) THE HYDRAULIC CALCULATIONS THAT WERE DONE ON SHT. 4 | | | TO REDUCE THE CAPACITY OF THE COLLECTOR TANKS WERE | | | BASED ON A FLOW RATE OF 185 GPM BUT THE FLOW RATE ON | | | SHT.1 IN THE POOL DATA TABLE SHOWS A FLOW RATE OF 155 | | | GPM. CLARIFY. | | | 3) THERE WAS NO MSDS DOCUMENTATION ATTACHED TO THE | | | RESPONSE LETTER FROM THE ENGINEER AS NOTED IN HIS | | | RESPONSE TO COMMENT # 8. CLARIFY. | | | 4) THERE WERE NO SPECIFICATIONS SUBMITTED FOR THE POOL | | | HEATER. THIS INFORMATION CAN BE SUBMITTED WHEN THE GAS | | | PERMIT IS SUBMITTED. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-05-18 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2016-05-18 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2016-05-18 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2016-05-18 09:43:25 | PROVISO: ROW ENCROACHMENT SHALL BE APPROVED BEFORE | | | FINAL CO. |
|
|