| Plan Review Stops For Permit 16041056 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2016-09-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-09-15 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-09-14 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2016-09-15 16:37:57 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16041056 | | | ADD: 701 VILLAGE BLVD. SUITES: 201-202 | | | CONT: GREAT PATRIOT CONSTRUCTION | | | TEL: 561-241-4765 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 5TH REVIEW | | | DATE: THURS. SEPT. 15/ 2016 | | | ACTION: BUILDING PROVISO | | | | | | ROOFING PROVISO: | | | CONTRACTOR SUBMITTED A FLORIDA APPROVAL # FL7804-R9 | | | ENTEGRA ROOF TILE. | | | LIMITATION 5.4 THIS APPROVAL DOES NOT PROVIDE | | | ATTACHMENT METHOD FOR MORTAR SET TILE OR ADHESIVE-SET | | | ADHESIVE APPLICATIONS PLEASE PROVIDE PRODUCT APPROVALS | | | FOR MORTAR SET TILE OR ADHESIVE-SET ADHESIVE | | | APPLICATION. | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES. | | | | | | 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED BY THE CODE, THE | | | CONSTRUCTION DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND | | | DELINEATE THE TYPE OF ROOFING SYSTEM, MATERIALS, | | | FASTENING REQUIREMENTS, FLASHING REQUIREMENTS AND WIND | | | RESISTANCE RATING THAT ARE REQUIRED TO BE INSTALLED. | | | PRODUCT EVALUATION AND INSTALLATION SHALL INDICATE | | | COMPLIANCE WITH THE WIND CRITERIA REQUIRED FOR THE | | | SPECIFIC SITE OR A STATEMENT BY AN ARCHITECT OR | | | ENGINEER FOR THE SPECIFIC SITE MUST BE SUBMITTED WITH | | | THE CONSTRUCTION DOCUMENTS. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2016-08-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-08-25 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-08-25 |
Time |
06:41 |
Sent To |
|
|
| Notes |
| 2016-08-25 08:20:39 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16041056 | | | ADD: 701 VILLAGE BLVD. SUITES: 201-202 | | | CONT: GREAT PATRIOT CONSTRUCTION | | | TEL: 561-241-4765 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 4TH REVIEW | | | DATE: THURS. AUGUST. 25/2016 | | | ACTION: DENIED | | | | | | 1) COVERSHEET/ 01-A: | | | | | | 1A-E) COMPLIED. | | | | | | 1F)4TH REQUEST. UNDER THE HEADING OF EARTHWORK THERE IS | | | NO REQUIREMENT FOR SOILS TESTING. THIS AREA IS IN A | | | QUESTIONABLE SOILS ZONE. | | | FBC-B 1803.5.2 QUESTIONABLE SOIL. WHERE THE | | | CLASSIFICATION, STRENGTH OR COMPRESSIBILITY OF THE SOIL | | | IS IN DOUBT OR WHERE A LOAD-BEARING VALUE SUPERIOR TO | | | THAT SPECIFIED IN THIS CODE IS CLAIMED, THE BUILDING | | | OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A | | | GEOTECHNICAL INVESTIGATION BE CONDUCTED. | | | | | | 2) COMPLIED. | | | | | | 3) 4TH REQUEST. THE YKK AP AMERICA DOES NOT HAVE | | | CURRENT PRODUCTS APPROVALS FOR THE STOREFRONT WINDOW | | | SYSTEM NOR THE STOREFRONT DOOR SYSTEM. IF SO PLEASE | | | SUPPLY THE FLORIDA APPROVAL COVERSHEETS. | | | | | | WINDOW SCHEDULE / TYPE 01 INDICATES THIS TYPE WINDOW TO | | | BE A SLIDER TYPE WINDOW WHEREAS A SINGLE HUNG APPROVAL | | | WAS SUBMITTED. | | | | | | ROOF TILE FLORIDA APPROVAL FL7804-R9 SUBMITTED ON PAGE | | | 6 OF 6 THE INSTALLATION TYPES MECHANICALLY, MORTAR OR | | | ADHESIVE- SET TILE NOR HIP & RIDGE TILE WERE INCLUDED | | | IN THIS SUBMITTAL. | | | | | | 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | | | | | 4) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | | RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | 5) COMPLIED. | | | | | | 6) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2016-07-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-07-20 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-07-20 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2016-07-20 10:06:16 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16041056 | | | ADD: 701 VILLAGE BLVD. SUITES: 201-202 | | | CONT: GREAT PATRIOT CONSTRUCTION | | | TEL: 561-241-4765 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: WED. JULY 20/2016 | | | ACTION: DENIED | | | | | | 1) COVERSHEET/ 01-A: | | | | | | 1A-E) COMPLIED. | | | | | | 1F) UNDER THE HEADING OF EARTHWORK THERE IS NO | | | REQUIREMENT FOR SOILS TESTING. THIS AREA IS IN A | | | QUESTIONABLE SOILS ZONE. | | | FBC-B 1803.5.2 QUESTIONABLE SOIL. WHERE THE | | | CLASSIFICATION, STRENGTH OR COMPRESSIBILITY OF THE SOIL | | | IS IN DOUBT OR WHERE A LOAD-BEARING VALUE SUPERIOR TO | | | THAT SPECIFIED IN THIS CODE IS CLAIMED, THE BUILDING | | | OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A | | | GEOTECHNICAL INVESTIGATION BE CONDUCTED. | | | | | | 2) COMPLIED. | | | | | | 3) THE YKK AP AMERICA DOES NOT HAVE CURENT PRODCT | | | APPROVALS FOR THE STOREFRONT WINDOW SYSTEM NOR THE | | | STOREFRONT DOOR SYSTEM. | | | | | | 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | | ( E ) SHUTTERS THE FABRIC STORM SYSTEM HAS AN EXPIRED | | | NOA. NEED TO SUBMIT THE WHOLE REPORT. | | | | | | 4) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | | RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | 5A) COMPLIED. | | | | | | 5B) THE OTHER ISSUE IS THE CONNECTION OF THE I-BEAM TO | | | THE STEEL COLUMN, THE PLANS INDICATE A CONTINUOUS WELD, | | | BUT THE TYPE OF WELD NOT PROVIDED. THIS WILL BE A SITE | | | CONNECTION, PLEASE HAVE THE WELDERS CERTIFICATE ON SITE | | | FOR INSPECTOR AT TIME OF INSPECTION. 107.2.1.3. | | | ADDITIONAL INFORMATION IS REQUIRED. THIS CONNECTION | | | WILL BE PART OF THE MWFRS (MAIN WIND FORCE RESISTING | | | SYSTEM. | | | | | | 6) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-05-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-05-17 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-05-17 |
Time |
07:29 |
Sent To |
|
|
| Notes |
| 2016-05-17 13:34:34 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16041056 | | | ADD: 701 VILLAGE BLVD. SUITES: 201-202 | | | CONT: GREAT PATRIOT CONSTRUCTION | | | TEL: 561-241-4765 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. MAY 17/2016 | | | ACTION: DENIED | | | | | | 1) COVERSHEET/ 01-A: | | | | | | 1A) UPPER RIGHT HAND CORNER OF THE PLANS UNDER THE | | | HEADING OF NOTES THE BUILDING CLASSIFICATION IS | | | INDICATES AS ASSEMBLY AND THE 2ND LINE THE OCCUPANCY | | | PER THE FBC CHAPTER 6 ASSEMBLY (NON-SEPARATED). | | | PLEASE NOTE THE DESIGNER OF RECORD HAS NOT DECLARED | | | WHAT CLASSIFICATION TYPE OF OCCUPANCY, THIS APPEARS TO | | | BE AN OCCUPANCY TYPE A2, SEE 2014 FBC-B 303.3. | | | | | | THE OTHER ISSUE DECLARING ASSEMBLY NON-SEPARATED PER | | | CHAPTER 6 WOULD BE THE WRONG CODE SECTION FOR | | | NON-SEPARATED USE. THE OTHER OCCUPANCY HAS NOT BEEN | | | DECLARED. | | | | | | SEE 2014 FBC-B 508.3.1 OCCUPANCY CLASSIFICATION. | | | NONSEPARATED OCCUPANCIES SHALL BE INDIVIDUALLY | | | CLASSIFIED IN ACCORDANCE WITH SECTION 302.1. THE | | | REQUIREMENTS OF THIS CODE SHALL APPLY TO EACH PORTION | | | OF THE BUILDING BASED ON THE OCCUPANCY CLASSIFICATION | | | OF THAT SPACE. IN ADDITION, THE MOST RESTRICTIVE | | | PROVISIONS OF CHAPTER 9 WHICH APPLY TO THE NONSEPARATED | | | OCCUPANCIES SHALL APPLY TO THE TOTAL NONSEPARATED | | | OCCUPANCY AREA. | | | | | | 1B) UNDER BOTH HEADINGS OF NOTES AND LOAD SCHEDULES, | | | WIND DESIGN THE PLANS WERE DESIGNED TO A WIND EXPOSURE | | | OF ?B?. TO BOTH THE WEST AND EAST THERE ARE VECTORS | | | THAT MEET THE QUALIFICATIONS FOR A SURFACE ROUGHNESS | | | C.FBC-B 1609.4.2. OPEN TERRAIN WITH SCATTERED | | | OBSTRUCTIONS HAVING HEIGHTS GENERALLY LESS THAN 30 FEET | | | (9144 MM). THIS CATEGORY INCLUDES FLAT OPEN COUNTRY, | | | AND GRASSLANDS. THIS SURFACE ROUGHNESS SHALL ALSO APPLY | | | TO ANY BUILDING LOCATED WITHIN SURFACE ROUGHNESS B TYPE | | | TERRAIN WHERE THE BUILDING IS WITHIN 100 FEET (30 M) | | | HORIZONTALLY IN ANY DIRECTION OF OPEN AREAS OF SURFACE | | | ROUGHNESS C OR D-TYPE TERRAIN THAT EXTENDS MORE THAN | | | 600 FEET (182.9 M) IN THE UPWIND DIRECTION AND A WIDTH | | | GREATER THAN 150 FEET (46 M). PLEASE UPDATE THE WIND | | | EXPOSURE TO AN C EXPOSURE AS WELL AS UPDATE THE | | | PRESSURES FOR ALL BUILDING WIND ZONES 1-5, ALL ARE LOW, | | | PLEASE ALSO REVIEW TABLE 1609.7(2) ADJUSTMENT FACTOR | | | FOR BUILDING HEIGHT AND EXPOSURE . | | | | | | 1C) UNDER THE HEADING OF LOAD SCHEDULE / WIND THE | | | BUILDING RISK CATEGORY WAS HAND WRITTEN IN PLEASE | | | PROVIDE THE CORRECT RISK FACTOR FOR THIS BUILDING. | | | TABLE 1604.5. | | | | | | 1D) UNDER THE HEADING NOTES, THE 2014 FBC-B WAS THE | | | DOCUMENT THE PLANS WERE TO BE DESIGNED TO, PLEASE BE | | | AWARE THE 2014 EXISTING BUILDING CODE IS THE OTHER CODE | | | THIS REVIEW WILL OCCUR UNDER. THE DESIGNER OF RECORD | | | HAS NOT INDICATED TO WHAT METHOD CODE COMPLIANCE WAS | | | CONSIDERED. 2014 EXISTING BUILDING CODE 301.1 GENERAL. | | | THE REPAIR, ALTERATION, CHANGE OF OCCUPANCY, ADDITION | | | OR RELOCATION OF ALL EXISTING BUILDINGS SHALL COMPLY | | | WITH ONE OF THE METHODS LISTED IN SECTIONS 301.1.1 | | | THROUGH 301.1.3 AS SELECTED BY THE APPLICANT. | | | APPLICATION OF A METHOD SHALL BE THE SOLE BASIS FOR | | | ASSESSING THE COMPLIANCE OF WORK PERFORMED UNDER A | | | SINGLE PERMIT UNLESS OTHERWISE APPROVED BY THE CODE | | | OFFICIAL. SECTIONS 301.1.1 THROUGH 301.1.3 SHALL NOT BE | | | APPLIED IN COMBINATION WITH EACH OTHER. WHERE THIS CODE | | | REQUIRES CONSIDERATION OF THE SEISMIC FORCE-RESISTING | | | SYSTEM OF AN EXISTING BUILDING SUBJECT TO REPAIR, | | | ALTERATION, CHANGE OF OCCUPANCY, ADDITION OR RELOCATION | | | OF EXISTING BUILDINGS, THE SEISMIC EVALUATION AND | | | DESIGN SHALL BE BASED ON SECTION 301.1.4 REGARDLESS OF | | | WHICH COMPLIANCE METHOD IS USED. | | | | | | 1E) THE SITE AND BUILDING DATA LIST 3,427 SQ. FT. IN | | | THIS BAY. SHEET 02-A LIST 17,724 SQ. FT. IN THE | | | BUILDING, PLEASE PROVIDE WHEN TABLE 503 FOR AN A2 | | | OCCUPANCY, BUILDING TYPE III-B, HOW CODE COMPLIANCE WAS | | | ACHIEVED WHEN ONLY 9,500 SQ. FT. IS ALLOWED? THE PLAN | | | DOES NOT INDICATE THAT ANY INCREASES WERE TAKEN! | | | 1F) UNDER THE HEADING OF EARTHWORK THERE IS NO | | | REQUIREMENT FOR SOILS TESTING. THIS AREA IS IN A | | | QUESTIONABLE SOILS ZONE. | | | FBC-B 1803.5.2 QUESTIONABLE SOIL. WHERE THE | | | CLASSIFICATION, STRENGTH OR COMPRESSIBILITY OF THE SOIL | | | IS IN DOUBT OR WHERE A LOAD-BEARING VALUE SUPERIOR TO | | | THAT SPECIFIED IN THIS CODE IS CLAIMED, THE BUILDING | | | OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A | | | GEOTECHNICAL INVESTIGATION BE CONDUCTED. | | | | | | 2)SHEET 18F APPEARS TO BE THE LIFE SAFETY SHEET. PLEASE | | | PROVIDE THE DOORWAYS THAT ARE TO BE THE MEANS OF | | | EGRESS. SHEET 09-A THE ELEVATIONS APPEAR TO HAVE A SLAT | | | SYSTEM OVER THE OPENINGS IN THE WALLS AND THE ONLY | | | EGRESS FROM THE NEW ADDITION IS BACK THROUGH THE | | | EXISTING BUILDING. SHOW THE OCCUPANT LOAD FOR THE | | | EXISTING TENANT SPACE AS WELL AS THE ADDITION SHOW | | | COMPLIANCE WITH; | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR | | | BUILDINGS. | | | 107.3.5.1.1 COMMERCIAL BUILDINGS: | | | (7) OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: | | | OCCUPANCY LOAD NOTE RECEPTION IS NOT BUSINESS, SEE | | | TABLE 1004.1.2 STANDING ONLY 5 NET | | | GROSS | | | NET | | | MEANS OF EGRESS | | | EXIT ACCESS | | | EXIT | | | EXIT DISCHARGE | | | DOORS | | | EMERGENCY LIGHTING AND EXIT SIGNS | | | MINIMUM CONSTRUCTION TYPE | | | | | | | | | 3) 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | | ( E ) SHUTTERS | | | (G) PRE-ENGINEERED A/C STANDS | | | | | | 4) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | | RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | 5A) SHEET 07-A & 11-A BOTH SHOW THE USE OF W12X26 | | | I-BEAMS. SHEET 11-A INDICATES INFILL WITH (2) 2X12S AND | | | ? INCH BOLTS. THE BOLT SPACING HAS NOT BEEN PROVIDED | | | NOR THE DIAMETER OF THE HOLE IN THE STEEL. | | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 5B) THE OTHER ISSUE IS THE CONNECTION OF THE I-BEAM TO | | | THE STEEL COLUMN, THE PLANS INDICATE A CONTINUOUS WELD, | | | BUT THE TYPE OF WELD NOT PROVIDED. THIS WILL BE A SITE | | | CONNECTION, PLEASE HAVE THE WELDERS CERTIFICATE ON SITE | | | FOR INSPECTOR AT TIME OF INSPECTION. 107.2.1.3. | | | ADDITIONAL INFORMATION IS REQUIRED. | | | THIS CONNECTION WILL BE PART OF THE MWFRS (MAIN WIND | | | FORCE RESISTING SYSTEM. | | | | | | 6) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-05-05 |
|
|
Cont ID |
|
| Sent By |
gearl |
Date |
|
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-05-17 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2016-05-05 10:46:03 | WRONG CODE APPLIED IN SYSTEM | | 2016-05-03 11:22:02 | | | | | | | | | | 1. NEED VENT FOR URINAL FBC PLUMBING 901.2 | | | | | | 2. NEED TO SHOW ON PLANS WHICH VENT IS GOING THRU ROOF | | | | | | | | | | | | NOTE THIS JOB WILL NEED A GAS PERMIT | | | | | | | | | GEORGE EARL PLUMBING PLANS REVIEWER 0013B |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2016-09-28 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-09-28 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-09-28 |
Time |
11:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2016-08-29 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-08-29 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-08-29 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2016-08-29 13:08:46 | 3RD ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 NEC | | | PENDING COMMENTS: | | | | | | 1. PLEASE CLARIFY SHEET 13-E SUBMITTED REFLECTING PANEL | | | SCHEDULES AND SERVICE ONE-LINE, IS THIS INSERT | | | INCORRECT OR IS IT PART OF CONSTRUCTION DOCUMENTS. ONE | | | SET HAS IT INCLUDED THE OTHER SET DOESNT. CLARIFY SHEET | | | IS NOT SIGNED AND SEALED BY EOR. FBC 107.3.5 | | | 2. PRIOR COMMENTS ADDRESSED. | | | 3. PLEASE FEEL FREE TO CONTACT ME SHOULD YOU HAVE ANY | | | QUESTIONS REGARDING THIS PROJECT. | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2016-07-14 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-07-14 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-07-14 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2016-07-14 07:53:19 | 2ND ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 NEC | | | COMMENTS: | | | | | | 1. PLEASE CLARIFY SHEET 13-E SUBMITTED REFLECTING PANEL | | | SCHEDULES AND SERVICE ONE-LINE, IS THIS INSERT | | | INCORRECT OR IS IT PART OF CONSTRUCTION DOCUMENTS. | | | SHEET IS NOT SIGNED AND SEALED BY EOR. FBC 107.3.5 | | | 2. PRIOR COMMENTS ADDRESSED. | | | 3. PLEASE FEEL FREE TO CONTACT ME SHOULD YOU HAVE ANY | | | QUESTIONS REGARDING THIS PROJECT. | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-05-05 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-05-05 |
Time |
07:07 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-05-04 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2016-05-05 07:08:06 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 NEC | | | COMMENTS: | | | | | | 1. PLEASE REFERENCE ALL APPLICABLE FBC ENERGY | | | CONSERVATION2014 5TH EDITION C405 REQUIREMENTS RELATED | | | TO AUTOMATIC MEANS OF CONTROL FOR ALL LIGHTING. | | | 2. STATE ON DRAWINGS C405.7.4 COMPLETION | | | REQUIREMENTS-(DRAWINGS AND MANUALS. SEE VERBIAGE IN THE | | | CODE. | | | 3. PROVIDE A SHOW ON PLANS THE VOLTAGE DROP | | | CALCULATIONS FOR FEEDER AND BRANCH CIRCUITS PER FBC EC | | | C405.7 ELECTRICAL POWER MANDATORY | | | 4. ADDRESS ALL AND ANY FIRE DEPARTMENT COMMENTS RELATED | | | TO THE ELECTRICAL SCOPE. | | | 5. LABEL THE ONE-LINE SERVICE RISER MAINS TO BE RATED | | | FOR SERVICE ENTRANCE. A NOTE WILL SUFFICE. | | | 6. PROVIDE A GENERAL NOTE TO INDICATE NEC 110.16 ARC | | | FLASH HAZARD WARNINGS- A NOTE WILL SUFFICE. | | | 7. PER NEC 110.24 A AND B. INDICATE ON PLANS REQUIRED | | | FIELD MARKING OF THE AVAILABLE FAULT CURRENT DUE TO | | | MODIFICATIONS. | | | 8. PLEASE CORRECT SERVICE CONDUCTORS SHOWN ON ONE-LINE | | | RISER DIAGRAM FOR 225A SERVICE AT 2/0, SHOULD REFLECT | | | 4/0 PER TABLE OF AMPACITIES NEC 310.15B16 | | | 9. SHOW SIZE OF THE GROUNDING ELECTRODE CONDUCTOR PER | | | NEC 250.66 | | | 10. PROVIDE NEUTRAL CALCULATIONS AS THE NEUTRAL IS | | | BEING REDUCED AS SHOWN SERVICE CONDUCTORS. NEC 220.61B | | | 11. SHOW ON FLOOR PLAN THE LOCATION OF THE SERVICE | | | EQUIPMENT. FBC 107.3.5 | | | 12. PER NEC 230.2 YOU ARE SHOWING MULTIPLE SERVICES. | | | PROVIDE A NOTE TO INDICATE PROPER SIGNAGE FOR FIRST | | | RESPONDERS WITH IDENTIFICATION PER NEC 230.2E | | | 13. CLARIFY THE LOCATION OF THE MAIN CIRCUIT BREAKER A | | | AND B. IS THE CONDUIT ROUTED UNDERGROUND? MAINS TO | | | LOCATED AT THE NEAREST POINT OF ENTRANCE PER NEC 230 | | | 14. CLARIFY SHOW WINDOW RECEPTACLE REQUIREMENTS FOR | | | COMMERCIAL BUILDINGS PER NEC 220.43 NEC 210.62 | | | 15. LABEL ON FLOOR PLAN ALL RECEPTACLE OUTLETS AT THE | | | TERRACE LOCATION TO BE GFCI PROTECTED AND W/P PER NEC | | | 210.8B | | | 16. BAR AREA RECEPTACLES AND RECEPTACLE WITHIN 6FT OF | | | MOP SINK TO LABELED GFCI PROTECTED. NEC 210.8B7 | | | 17. DRINKING FOUNTAIN CIRCUIT A-8 TO BE A DEDICATED | | | CIRCUIT AND LABELED GFCI PROTECTED. OTHER RECEPTACLES | | | ON CIRCUIT A-8 TO BE REASSIGNED WITH OTHER CIRCUIT | | | DESIGNATION. NEC 422.52 | | | 18. DELETE GENERAL NOTES ON SHEETS 14 AND 15E THAT ARE | | | NOT APPLICABLE TO THIS PROJECT. RESIDENTIAL NOTES. | | | 19. SHOW REQUIRED EXIT AND EMERGENCY LIGHTING FOR AREAS | | | AND EGRESS DOORS. FBC 107.3.5 | | | 20. SEPARATE PERMITS REQUIRED FOR ALL LOW VOLTAGE | | | SYSTEMS AND FIRE ALARM. PROVIDE A NOTE | | | 21. FURTHER COMMENTS MAY FOLLOW UPON RESUBMITTAL. | | | PLEASE FEEL FREE TO CONTACT ME SHOULD YOU HAVE ANY | | | QUESTIONS REGARDING THIS PROJECT. | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2016-08-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-08-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-08-17 |
Time |
14:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2016-07-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-07-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-07-14 |
Time |
13:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2016-04-28 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-04-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-04-27 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2016-04-27 17:00:51 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | 1) SHEET 08 A - THERE IS NOTE INDICATING A FIREPIT BY | | | SPECIALIST. | | | | | | THE FIREPIT SHALL BE SUBMITTED UNDER SEPARATE SHOP | | | DRAWINGS IN COMPLIANCE WITH NFPA 1, CHAPTER 10, | | | | | | 10.11.8 INCINERATORS AND FIREPLACES. | | | 10.11.8.1 INCINERATORS, OUTDOOR FIREPLACES, PERMANENT | | | BARBECUES, AND GRILLS SHALL NOT BE BUILT, INSTALLED, OR | | | MAINTAINED WITHOUT PRIOR APPROVAL OF THE AHJ. | | | 10.11.8.2 INCINERATORS, OUTDOOR FIREPLACES, PERMANENT | | | BARBECUES, AND GRILLS SHALL BE MAINTAINED IN GOOD | | | REPAIR AND IN A SAFE CONDITION AT ALL TIMES. | | | 10.11.8.3 OPENINGS IN INCINERATORS, OUTDOOR FIREPLACES, | | | PERMANENT BARBECUES, AND GRILLS SHALL BE PROVIDED WITH | | | AN APPROVED SPARK ARRESTER, SCREEN, OR DOOR. | | | 10.11.9 OPEN-FLAME DEVICES. | | | 10.11.9.1* WELDING TORCHES, TAR POTS, DECORATIVE | | | TORCHES, AND OTHER DEVICES, MACHINES, OR PROCESSES | | | LIABLE TO START OR CAUSE FIRE SHALL NOT BE OPERATED OR | | | USED IN OR UPON ANY AREAS, EXCEPT BY PERMIT FROM THE | | | AHJ. | | | | | | THE FLAME OF THE PIT SHALL BE PROTECTED AGAINST | | | ACCIDENTAL AND/OR INTENTIONAL USE AND/OR MISUSE. | | | | | | IT IS IMPERATIVE FOR THE APPROVAL OF THIS DEVICE TO BE | | | INSTALLED, SOMESORT OF DESIGN FEATURE SHALL BE | | | INSTALLED TO PREVENT FLAME CONTACT WITH THE GENRAL | | | PUBLIC. | | | | | | 2) SHEET 18 F - THERE IS A NOTE INDICATING FIRE | | | SPRINKLER BY SPECIALIST. | | | | | | ANY AND ALL FIRE SPRINKLER WORK SHALL BE DONE UNDER | | | SEPARATE SHOP DRAWINGS BY CERTIFIED LIFE SAFETY | | | CONTRACTORS. | | | | | | 3) SHEET 18 F - THE EXIT SIGN IN THE MIDDLE OF THE | | | INTERIOR WALL SHALL BE MOVED TO THE AREA OF THE DOOR | | | WAY LEADING TO THE CORRIDOR. | | | | | | 4) SHEET 18 F - THERE ARE NO EXIT SIGNS LOCATED IN THE | | | TERRACE AREA. ADD AN EXIT SIGN AT EACH END OF THE | | | TERRACE. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2016-09-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-09-28 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-09-23 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2016-09-26 11:14:00 | RESUB ROUTED TO AWOOTEN VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-08-29 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-08-29 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-08-11 |
Time |
10:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-08-02 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-08-02 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-07-08 |
Time |
14:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-05-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-05-17 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-04-22 |
Time |
11:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2016-09-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-09-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-09-14 |
Time |
|
Sent To |
|
|
| Notes |
| 2016-09-14 16:46:34 | P. B. COUNTY IMPACT FEE OFFICE | | | TRACKING NO. MU-2016-022577-0000 | | | RECEIPT NO. 2016-0913-298 | | | FEES: $7,038.83 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2016-08-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-08-25 |
Time |
06:44 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-08-25 |
Time |
06:44 |
Sent To |
|
|
| Notes |
| 2016-08-25 06:44:48 | IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2016-05-17 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2016-05-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2016-05-17 |
Time |
|
Sent To |
|
|
| Notes |
| 2016-08-25 06:44:16 | IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2016-05-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-05-17 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-05-17 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2016-05-17 13:31:14 | IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2016-09-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-09-28 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-09-28 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2016-09-28 11:12:55 | MECHANICAL PROVISO | | | PERMIT #16041056 | | | 9/28/16 | | | | | | THE CURRENT MECHANICAL PLANS ARE APPROVED WITH A | | | CONTINGENCY FOR A REVISION TO BE SUBMITTED TO CORRECT A | | | DEFICIENCY IN THE SMOKING LOUNGE EXHAUST VENTILATION | | | SYSTEM. | | | AS PREVIOUSLY NOTED IN PRIOR REVIEWS, RECIRCULATION OF | | | AIR IN THE LOUNGE AREA IS PROHIBITED PER TABLE 403.3 | | | FOOTNOTE B, AND SECTION 403.2.1 ITEM 3. ALL AIR | | | SUPPLIED TO SUCH AREAS SHALL BE EXHAUSTED, HOWEVER THE | | | PLAN INDICATES ONLY 2700 CFMS OF THE 3000 CFMS SUPPLED | | | ARE BEING EXHAUSTED. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2016-08-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-08-24 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-08-24 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2016-08-24 16:22:35 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #16041056 | | | 8/24/16 | | | | | | 1) ENERGY FORM C402 MAY BE USED FOR ALTERATIONS, | | | RENOVATIONS, AND BUILDING SYSTEMS, HOWEVER THE PROJECT | | | IS A CHANGE OF OCCUPANCY- SEE SECTION C101.5.1.1 FBC-14 | | | ENERGY CONSERVATION. | | | | | | 2) REFER TO TABLE 403.3 FOOTNOTE B, AND SECTION | | | 403.2.1(3)- RECIRCULATION OF AIR IN THE SMOKING LOUNGE | | | IS PROHIBITED. THE CALCULATIONS INDICATE COMPLIANCE, | | | HOWEVER ERV'S WILL TYPICALLY LEAK A SMALL PERCENTAGE OF | | | RETURN AIR BACK INTO THE SUPPLY AIRSTREAM WHICH IS | | | LIMITED TO 10% PER SECTION 514.4. PLEASE SUBMIT | | | MANUFACTURER'S SPECIFICATIONS INDICATING THE LEAKAGE | | | RATE OF THE ERV. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-07-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-07-18 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-07-18 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2016-07-18 09:44:28 | 2ND REVIEW MECHANICAL | | | PERMIT #16041056 | | | 7/18/16 | | | | | | 1) THE RESUBMITTED PLANS INDICATE A CHANGE OF OCCUPANCY | | | TO A2- PLEASE SUBMIT ENERGY CALCULATIONS PER SECTION | | | C101.4.4 AND C401.2 FBC-14 ENERGY CONSERVATION. | | | | | | 2) AS PREVIOUSLY REQUESTED IN THE 1ST REVIEW, SUBMIT AC | | | COOLING AND HEATING CALCULATIONS PER SECTION 403.2.1 | | | FBC-14 ENERGY CONSERVATION. | | | | | | 3) M-1: THE VENTILATION CALCULATION FOR THE LOUNGE AREA | | | BASED ON 45 PERSONS IS INCORRECT. THE OCCUPANT DENSITY | | | PER TABLE 403.3 IS BASED ON 70 PERSONS PER SQ. FT. | | | REFER TO SHEET 18-F- THE INTERIOR LOUNGE IS LISTED AT | | | 944 SQ. FT. WHICH RESULTS IN A 66 PERSON OCCUPANT | | | DENSITY PER TABLE 403.3- PLEASE CORRECT. | | | | | | 4) M-1: THE VENTILATION CALCULATION DOES NOT INCLUDE | | | THE HUMIDOR ROOM, THE CORRIDOR/HALL 03, AND THE STORAGE | | | ROOMS 1 & 2, . PLEASE NOTE THE HUMIDOR ROOM HAS A | | | LISTED OCCUPANT LOAD OF 50 ON THE LIFE SAFETY PLAN- | | | SHEET 18-F. A) CLARIFY WAT TYPE OF PRODUCTS, OR | | | MATERIALS ARE BEING STORED IN THE STORAGE ROOMS. | | | | | | 5) M-1: REFER TO TABLE 403.3 FOOTNOTE E AND INDICATE | | | HOW EF-1 AND EF-2 WILL OPERATE- INTERMITTENTLY OR | | | CONTINUOUSLY. | | | | | | 6) AS PREVIOUSLY REQUESTED PROVIDE A COMPLETE | | | CONDENSATE DISPOSAL PLAN THAT INCLUDES THE NEW 100 % | | | O/A UNIT. | | | | | | 7) PROVIDE A MECHANICAL ROOF PLAN SHOWING ALL REQUIRED | | | CLEARANCES FOR THE OUTDOOR AIR INTAKES TO EXHAUST AND | | | VENT OUTLETS- SEE SECTION 401.4. | | | | | | 8) 2ND REQUEST FOR AN AIR DEVICE SCHEDULE. | | | | | | 9) M-2 PROVIDE THE WIND LOAD DESIGN CRITERIA INCLUDING | | | THE WIND SPEED, IMPORTANCE FACTOR, EXPOSURE CATEGORY, | | | AND HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT- SECTION | | | 301.15. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-05-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-05-06 |
Time |
17:02 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-05-06 |
Time |
17:02 |
Sent To |
|
|
| Notes |
| 2016-05-06 17:20:32 | 1ST REVIEW: FBC 2014 MECHANICAL, EXISTING BUILDING. | | | PERMIT #16041056 | | | 5/6/16 | | | | | | 1) THE MECHANICAL PLANS FOR THE PROPOSED PROJECT DO NOT | | | PROVIDE ENOUGH INFORMATION FOR PERMITTING. IN | | | ACCORDANCE WITH SECTION 1009.1 FBC-14 EXISTING | | | BUILDING, PLEASE PROVIDE THE FOLLOWING: | | | A) MINIMUM VENTILATION CALCULATIONS FOR ALL ROOMS AND | | | SPACES PER TABLE 403.3 FBC-14 MECHANICALL. PROVIDE A | | | SCHEDULE INDICATING THE REQUIRED AND PROVIDED CFM'S OF | | | OUTDOOR AIR. PLEASE NOTE ALL AIR SUPPLIED TO INDOOR | | | SMOKING LOUNGES SHALL BE EXHAUSTED AND SHALL NOT BE | | | RE-CIRCULATED- SEE TABLE 403.3 FOOTNOTE B, AND SECTION | | | 403.2.1 (3). | | | B) AC COOLING AND HEATING CALCULATIONS FOR THE NEW | | | HUMIDOR SYSTEM PER SECTION C403.2.1 FBC-14 ENERGY | | | CONSERVATION. | | | C) AC EQUIPMENT SCHEDULES FOR ALL NEW AND EXISTING AC | | | SYSTEMS. | | | D) SUPPLY AND RETURN CFM'S AT ALL DIFFUSER AND RETURN | | | GRILL LOCATIONS. | | | E) AIR BALANCE CALCULATIONS- SEE SECTION 501.4 FBC-14 | | | MECHANCIAL. | | | F) AIR DEVICE SCHEDULE | | | G) DUCT HANGING, SUPPORT, AND CONNECTION AND | | | REINFORCEMENT DETAILS. | | | H) CONDENSATE DISPOSAL DETAILS PER SECTION 307 | | | I) WIND LOAD TIE-DOWN ENGINEERING FOR THE NEW ROOF TOP | | | AC SYSTEM- SECTION 301.15. | | | 2) CLARIFY WHY NO RETURN SYSTEMS ARE SHOWN FOR THE AC | | | SYSTEMS SUPPLYING THE RETAIL AREA- SEE SECTION 601.5 | | | FBC-=14 MECHANICAL. | | | 3) PLEASE NOTE ADDITIONAL COMMENTS MAY FOLLOW AFTER | | | CORRECTED PLANS ARE SUBMITTED. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-07-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-07-20 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-07-20 |
Time |
12:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-05-16 |
|
|
Cont ID |
|
| Sent By |
gearl |
Date |
2016-05-16 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-05-03 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2016-05-16 16:22:03 | | | | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS | | | | | | | | | | | | | | | 1. NEED VENT FOR URINAL FBC PLUMBING 901.2 | | | | | | 2. NEED TO SHOW ON PLANS WHICH VENT IS GOING THRU ROOF. | | | PER WPB AMEND. TO FBC 107.2.1 | | | | | | | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | | GAS SEC. 301.3. | | | | | | A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION. | | | | | | DO TO PLANS BEING INCOMPLETE OR UNCLEAR, A | | | COMPREHENSIVE PLAN REVIEW CANNOT BE DONE AT THIS TIME, | | | THERE MAYBE ADDITIONAL COMMENTS ON RESUBMITTAL OF | | | PLANS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2016-09-27 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2016-09-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2016-09-27 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2016-09-26 15:08:59 | ROUTED TO ALANA WOOTEN |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2016-08-24 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2016-08-24 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2016-08-22 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2016-08-24 09:48:12 | ***ZONING FAILED**** | | | | | | THERE IS A LANDSCAPE PLAN THAT IS A PART OF THE | | | APPROVAL FOR THE MINOR AMENDMENT PB812M TO THE VILLAGE | | | COMMONS PLANNED DEVELOPMENT FOR THIS PERMIT. PLEASE | | | SUBMIT SEPARATE LANDSCAPE AND IRRIGATION PLANS | | | ACCORDING TO APPROVED LANDSCAPE PLAN. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | ALANA WOOTEN, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1449 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2016-07-26 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2016-07-26 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2016-07-26 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2016-07-26 15:35:08 | THE LANDSCAPE ON THE SITE SHALL BE IN COMPLIANCE WITH | | | ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF THE | | | ZLDR. IF THE SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) | | | COPIES OF A LANDSCAPE PLAN DEMONSTRATING COMPLIANCE | | | SHALL BE INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE | | | SITE DOES NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE | | | ZONING APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE | | | PERMIT AND IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING | | | MATERIAL TO BRING THE SITE INTO CONFORMITY. | | | | | | PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON THE | | | PROPERTY, A TREE ALTERATION PERMIT SHALL BE SUBMITTED, | | | REVIEWED AND APPROVED BY THE DEVELOPMENT SERVICES | | | DEPARTMENT, PLANNING DIVISION. PLEASE CONTACT THE | | | PLANNING DIVISION FOR MORE INFORMATION. (561) 822-1435, | | | 401 CLEMATIS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | ALANA WOOTEN, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: 561-822-1449 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2016-05-06 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2016-05-06 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2016-05-06 |
Time |
12:10 |
Sent To |
|
|
| Notes |
| 2016-05-06 16:08:45 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 5/6/16 | | | | | | 1. THE PROPOSED ADDITION TO THE SITE REQUIRES A MINOR | | | PLANNED DEVELOPMENT (PD) APPROVAL THROUGH THE PLANNING | | | DIVISION PRIOR ZONING APPROVAL OF THE BUIDLING PERMIT. | | | A MINOR PD AMENDMENT APPLICANTION HAS BEEN SUBMITTED | | | AND IS STILL UNDER REVIEW BY THE PLANNING DIVISION. AT | | | THE TIME OF THIS REVIEW, A MINOR PD AMENDMENT APPROVAL | | | HAS NOT YET BEEN ISSUED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | |
|
|