| Plan Review Stops For Permit 16040999 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-08-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-08-11 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-08-09 |
Time |
09:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-07-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-07-26 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-07-26 |
Time |
11:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-05-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-05-24 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-05-24 |
Time |
12:16 |
Sent To |
|
|
| Notes |
| 2016-05-24 14:03:23 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. LS1.1, IT IS NOT CLEAR WHETHER OR NOT A CHANGE OF | | | OCCUPANCY IS APPLICABLE. REVISE PLAN TO INCLUDE THIS | | | INFORMATION. | | | | | | 2. LS1.1, CODE ANALYSIS REFERS TO A LAB, BUT I WAS | | | UNABLE TO LOCATE ON THE PLAN, FBC 107. | | | | | | 3. REVISE PLAN TO SHOW THE 18" CLEARANCE, PULL SIDE, | | | FBC 5TH ED. ACCESSIBILITY FIGURE 404.2.4.1 FOR DOORS | | | 106-1, 108-1, 119-2, DOOR TO FEMALE BATHROOM. | | | | | | 4. REVISE PLAN TO SHOW CORRIDOR WIDTH, REQUIRED WIDTH, | | | TO SHOW COMPLIANCE WITH FBC 5TH ED. BUILDING 1005.7.1. | | | | | | 5. USE OF THE MULTI PURPOSE ROOM IS NOT ENTIRELY CLEAR. | | | SEE FBC 5TH ED. ACCESSIBILITY 221. ALSO CLARIFY THE USE | | | OF WHAT APPEARS TO BE WORK STATIONS. REVISE THE PLAN TO | | | CLARIFY COMPLIANCE WITH (OR EXEMPTION TO) ACCESSIBILITY | | | REQUIREMENTS. | | | | | | 6. A ROOF REPORT WAS PROVIDED. INDICATE THE ASSEMBLY | | | PROPOSED AND, IF REQUIRED, PROVIDE ENGINEERING. IF THIS | | | IS NOT PROVIDED WITH THE RESUBMITTAL, THIS INFORMATION | | | WILL BE REQUIRED WITH THE ROOF PERMIT APPLICATION. | | | | | | 7. SHEET A6.2, HARDWARE AND FIRE RATING FOR DOORS | | | COLUMNS ARE BLANK. NOT ALL DOORS ON THE PLAN (FOR | | | INSTANCE, THE MULTI PURPOSE ROOM) ARE LABELED. FIRE | | | RATED WALLS AND A SMOKE PARTITION ARE SHOWN, BUT THE | | | DOOR SCHEDULE DOES NOT INDICATE THAT ANY DOORS WILL BE | | | RATED. REVISE TO CLARIFY, FBC 107. | | | | | | 8. IF THIS INCLUDES A CHANGE OF OCCUPANCY, IMPACT FEE | | | ASSESSMENT FROM PALM BEACH COUNTY IS REQUIRED. | | | 561-233-5025 FOR MORE INFORMATION. | | | | | | 9. PLEASE SEE PLUMBING COMMENTS REGARDING ACCESSIBLE | | | ELEMENTS. | | | | | | 10. COURTESY ADVISORY TO WARREN JOHNSON, PE; PLEASE SEE | | | FS 471.0195 AND 61G15-22.001, AN ADVANCED BUILDING CODE | | | COURSE IS REQUIRED BY JUNE 30, 2016. EVIDENCE IS TO BE | | | PROVIDED TO FBPE FOR WWW.MYFLORIDALICENSE.COM UPDATE. | | | | | | FOR MORE INFORMATION, SEE PAGE 4: | | | | | | HTTPS://WWW.FBPE.ORG/INDEX.PHP/FILE-DOWNLOADS/SEND/56-2 | | | 015-2016-FBPE-NEWSLETTERS/377-APRIL-2016-FBPE-NEWSLETTE | | | R | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-07-18 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-07-18 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-07-18 |
Time |
15:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-04-28 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-04-28 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-04-28 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2016-04-28 10:43:56 | JOB PERMIT NUMBER: 16040999 | | | JOB ADDRESS: 2823 AUSTRALIAN AVE | | | WEST PALM BEACH FLORIDA | | | DATE: APRIL 28 2016 | | | ELECTRICAL PLAN REVIEW COMMENTS | | | | | | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF | | | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, | | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | | | | - SHEET E1.1 NEC 210.63 HVAC EQUIPMENT SERVICE OUTLET. | | | A 125 VOLT, SINGLE-PHASE, 15 OR 20-AMPERE-RATED | | | RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE | | | LOCATION FOR THE SERVICING OF HVAC EQUIPMENT. THE | | | RECEPTACLE SHALL BE LOCATED WITHIN 25 FT OF THE | | | EQUIPMENT. MISSING FOR AC UNITS CU 1-3 , RTU 1-1 , QA 1 | | | , RTU 1-2. | | | - CLARIFY IF CIRCUIT L1A-9 IS A DRINKING FOUNTAIN ? IF | | | SO IT SHALL BE PROTECTED WITH A GFCI. NEC 422.52 | | | - SHEET E2.1 PENDANT LIGHTING OUTLET BOX IN THE CEILING | | | SHALL BE REQUIRED TO SUPPORT A LUMINAIRE WEIGHING A | | | MINIMUM OF 50 LB. ADD THIS TO THE NOTES ON CEILING | | | BOXES ON PAGE. | | | - FBC-E C402.4.8 RECESSED LIGHTING. RECESSED LIGHTING | | | INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE IC | | | RATED AND BE SEALED TO LIMIT AIR LEAKAGE BETWEEN | | | CONDITIONED & UNCONDITIONED SPACES. | | | - FBC-E C405.5. INTERIOR LIGHTING POWER REQUIREMENTS. A | | | BUILDING COMPLIES WITH THIS SECTION IF ITS TOTAL | | | CONNECTED LIGHTING POWER CALCULATED UNDER SECTION | | | C405.5.1 IS NO GREATER THAN THE INTERIOR LIGHTING POWER | | | CALCULATED UNDER SECTION C405.5.2. PROVIDE A LIGHTING | | | POWER DENSITY CHART TO SHOW COMPLIANCE. | | | - SHEET E3.1 FIRE ALARM SHALL BE ON A SEPARATE PERMIT. | | | - SHEET E4.1 PROVIDE AIC CALCS FOR EQUIPMENT AND | | | INTERRUPTING RATING OF OCPD. NEC 110.10 , 110.9. | | | | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | | MENTIONED DEFICIENCIES. | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | | STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD | | | INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE | | | OR ACTION TO SAME. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS FOR COMPARISON. | | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | FBC 2014 5TH ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6713 | | | [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2016-08-11 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-09-26 |
Time |
15:08 |
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2016-09-26 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2016-07-14 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-07-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-07-14 |
Time |
12:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2016-05-02 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-05-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-05-02 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2016-05-02 10:12:59 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) SHEET A 6.2 - THE DOOR SCHEDULE DOES NOT INCLUDE | | | INDICATIONS TO DOORS IN SMOKE PARTITIONS. | | | | | | PLEASE PROVIDE DETAILS IN THE DOOR SCHEDULE INDICATING | | | WHICH DOORS SHALL COMPLY WITH NFPA 101, CHAPTER 14, | | | 14.3.6 (A) & CHAPTER 8, 8.4. SMOKE PARTITIONS. | | | | | | 2) SHEET A 6.2 - THE DOOR SCHEDULE DOES NOT INDICATE | | | EXIT HARDWARE ON EXIT DOORS. | | | | | | PLEASE PROVIDE DETAILS IN THE DOOR SCHEDULE INDICATING | | | WHICH DOORS SHALL COMPLY WITH NFPA 101, CHAPTER 7, | | | MEANS OF EGRESS, 7.2.1.7 PANIC HARDWARE AND FIRE EXIT | | | HARDWARE. | | | | | | 3) SHEET A 1.1 - DOORS INDICATED AS 100 / 3 SHOW THEM | | | OPENING INTO THE EXIT CORRIDOR. | | | | | | PER SECTION NFPA 101, DOOR SWING DIRECTION, 7.2.1.4.2, | | | DOOR IS REQUIRED TO SWING IN THE DIRECTION OF EGRESS | | | TRAVEL FOR AN OCCUPANT LOAD OF 50 OR GREATER PERSONS. | | | PER NFPA 101 CHAPTER 7, MEANS OF EGRESS | | | 7.2.1.4.3 DOOR LEAF ENCROACHMENT | | | 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS | | | OF EGRESS SHALL LEAVE NOT LESS THAN ONE-HALF OF THE | | | REQUIRED WIDTH OF AN AISLE, A CORRIDOR, A PASSAGEWAY, | | | OR A LANDING UNOBSTRUCTED AND SHALL NOT PROJECT NOT | | | MORE THAN 7 IN. INTO THE REQUIRED WIDTH OF AN AISLE, A | | | CORRIDOR, A PASSAGE WAY, OR A LANDING, WHEN FULLY OPEN, | | | UNLESS BOTH OF THE FOLLOWING CONDITIONS ARE MET: | | | (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN | | | EXISTING BUILDING. | | | (2) THE DOOR OPENING MEETS THE REQUIREMENTS THAT LIMITS | | | PROJECTION TO NOT MORE THAN 7 IN. INTO THE REQUIRED | | | WIDTH OF THE STAIR LANDING WHEN THE DOOR LEAF IS FULLY | | | OPEN. | | | | | | PLEASE REVIEW AND PROVIDE INDICATIONS/DIMENSIONS | | | COMPLYING WITH THE THE CODE. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2016-09-26 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2016-09-26 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2016-09-09 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2016-09-12 08:41:05 | 9/12 TO ENGINEERING BOX | | | | | | | | 2016-09-09 13:25:20 | IMPACT FEES ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-08-11 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-08-11 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-08-04 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2016-08-11 10:28:00 | 8/11 TO SAK DESK TO COORDINATE ENGINEERING REVIEW | | | | | 2016-08-05 12:44:40 | RESUB ROUTED TO JROACH VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-07-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-07-28 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-06-30 |
Time |
15:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-05-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-05-24 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-04-22 |
Time |
10:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2016-09-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-09-12 |
Time |
07:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-09-12 |
Time |
07:35 |
Sent To |
|
|
| Notes |
| 2016-09-12 07:36:23 | MU-2016-022139-0000 | | | $18,728.29 PAID | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2016-07-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-07-26 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-07-26 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2016-07-26 12:36:16 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED. | | | PLEASE CONTACT 561-233-5025 FOR MORE INFORMATION. | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2016-05-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-05-24 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-05-24 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2016-05-24 14:16:04 | SEE BUILDING COMMENTS | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2016-07-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-07-05 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-07-05 |
Time |
16:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-05-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-05-03 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-05-03 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2016-05-03 12:54:10 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #16040999 | | | 5/3/16 | | | | | | 1) SHEET AD-1.3: PLEASE SHOW NOTE #2 LOCATIONS ON THE | | | PLAN- MECHANICAL EQUIPMENT TO BE REMOVED. | | | 2) THE OUTDOOR DRY BULB AND WET BULB COOLING | | | TEMPERATURES SHOWN ON THE PLANS ARE HIGHER THAN THE | | | TEMPERATURES INDICATED IN ACCA MANUUAL N FOR WPB WHICH | | | ARE 90 DEGREES AND 78 DEGREES. | | | 3) SHEET M4.1: THE VENTILATION CALCULATIONS INDICATE | | | 1523 CFM'S OF O/A REQUIRED FOR PHASE 1, HOWEVER THE AC | | | SCHEDULES INDICATE A TOTAL OF 1410 CFM'S TO BE | | | PROVIDED. | | | 4) M2.1: SEE NOTE #10 AND CLARIFY IF, UNDER THIS | | | PHASE-1, THE OA-1 WILL SHUT DOWN ALONG WITH THE DAMPER. | | | 5) M2.1: A DUCT SMOKE DETECTOR IS REQUIRED IN THE | | | RETURN AIR SYSTEM OF OA-1- SECTION 606.2.1. | | | 6) M2.1 & M6.1: THE CONTROL DIAGRAM FOR RTU-1-2 IS | | | ERRONEOUSLY SHOWING CONNECTION TO OA-1. | | | 7) M2.1: INDICATE HOW O/A IS BEING PROVIDED TO STORAGE | | | ROOM 100A | | | 8) M5.2 & S3.4: PROVIDE COMPLETE ENGINEERED DETAILS FOR | | | INSTALLATION OF THE ROOFTOP UNITS, AND SUBMIT A FL. | | | PRODUCT APPROVAL OR MIAMI-DADE NOA FOR THE THYBAR CURBS | | | APPROVED WITH SIGNATURE BY THE EOR. PLEASE NOTE THE | | | STRUCTURAL DETAIL SHOWS A WELDED CONNECTION FOR THE | | | CURB TO THE ROOF STRUCTURE. | | | 9) PROVIDE WIND LOAD ENGINEERING FOR THE INSTALLATION | | | OF CU-1-3 ON THE HOUSEKEEPING- SECTION 301.15. | | | 10) PROVIDE A FLORIDA PRODUCT APPROVAL OR MIAMI-DADE | | | NOA FOR THE EXHAUST LOUVERS. | | | 11) THE EOR MUST COMPLETE HIS MANDATORY REQUIREMENTS | | | CHECKLIST ON PAGE 10 OF THE ENERGY COMPLIANCE | | | SUBMITTAL. | | | 12) REFER TO SECTION C403.3.1.1.1: THE ECONOMIZER SHALL | | | BE CAPABLE OF MODULATING OUTDOOR AIR AND RETURN AIR | | | DAMPERS TO PROVIDE UP TO 100 PERCENT OF THE DESIGN | | | SUPPLY AIR QUANTITY AS OUTDOOR AIR FOR COOLING. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2016-08-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-08-02 |
Time |
18:20 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-08-02 |
Time |
18:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2016-07-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-07-28 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-07-28 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2016-07-28 10:41:13 | 2ND REVIEW | | | | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | | | | PLUMBING COMMENTS: | | | | | | 1. A GREASE INTERCEPTOR WAS ADDED TO PLAN PLEASE | | | PROVIDE SIZING CALCULATION FROM THE MANUFACTURE SCHIER | | | WILL SUPPLY A FORM FOR YOU TO SUBMIT. PER WPB AMEND. TO | | | FBC 107.2.1 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-05-06 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-05-06 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-05-04 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2016-05-06 17:45:26 | | | | | | | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE PROVIDE PROPOSED OCCUPANT LOAD AND USE FOR | | | SECOND FLOOR I UNDERSTAND ITS UNDER DIFFERENT PERMIT. | | | WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 2. SHT. LS 1.1 ON THE PLUMBING FIXTURE REQUIREMENT DOES | | | YOUR OCCUPANT LOAD INCLUDE SECOND FLOOR. WPB AMEND. TO | | | FBC SEC. 107.2.1 | | | | | | 3. SHT LS 1.1 YOU CALL OUT 7 TOILETS FOR MALE STUDENTS | | | I ONLY COUNT 6 INCLUDING 2ND FLOOR PLEASE CLARIFY. | | | 609.4 | | | | | | 4. SHT A-8.1 SHOW 16IN. MIN AND 18IN. MAX FROM SIDE | | | WALL TO CENTER OF TOILET COMPLY WITH 609.4 | | | | | | 5. SHT A-8.1 SHOW 33IN. MIN TO 36IN MAX MEASURED TO THE | | | TOP OF GRIPPING SURFACE ON THE GRAB BARS. FBC ACC. SEC. | | | 609.4 | | | | | | 6. SHT P 3.1 UP STREAM OF THE BACK TO BACK HANDICAP | | | TOILETS A HORIZONTAL DRY VENT IS NOT ALLOWED. PER FBC | | | PL 905.3 AND 4 | | | | | | 7. PROVIDE MANUFATURE SPEC SHEETS FOR OIL MINDER SUMP | | | PUMP AND WATER HEATERS. WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 8. PROVIDE STORM WATER RISER DIAGRAM WITH THE SQ FT. OF | | | AREA BEING DRAINED.WPB AMEND. TO FBC SEC. | | | 107.3.5.1.3(13) |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2016-07-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-07-26 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-07-26 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2016-07-26 14:27:36 | ROOF PERMIT APPLICATION AND ROOF ASSEMBLY (ALONG WITH | | | ENHANCED FASTENING ENGINEERING IF REQUIRED), TO BE | | | SUBMITTED FOR REVIEW PRIOR TO INSTALLATION. | | | FL 17013 SUBMITTED (JOHNS MANVILLE MODIFIED); PRESSURES | | | TO COMPLY WITH DPS ON SHEET S0.2. | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2016-05-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-05-24 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-05-24 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2016-05-24 14:15:19 | SEE BUILDING COMMENTS | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
N |
Date |
2016-07-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-07-26 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-07-26 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2016-07-26 17:33:37 | SEE SHEET LS1.2. THE PERMIT DOCUMENTS SHOW A TWO STORY | | | BUILDING WITH A SMALL ONE STORY ADDITION. THE PERMIT | | | DOCUMENTS DEPICT FUTURE RENOVATIONS (PHASE 2 AND PHASE | | | 3). THIS FUTURE WORK IS NOT INCLUDED IN THE SCOPE OF | | | THIS PERMIT, WITH THE EXCEPTION OF DEMOLITION (SHEET | | | AD1.1). THE FUTURE OCCUPANT LOAD, INCLUDING THE PHASE 2 | | | AND 3 BUILDOUTS, ARE INCLUDED IN THE PERMIT DOCUMENTS | | | TO FACILITATE THE FUTURE CONSTRUCTION. HOWEVER, THE | | | BUILDING AS IS TODAY DOES NOT FIT THE DEFINITION OF A | | | "THRESHOLD BUILDING" AS THE OCCUPANT LOAD OF THE | | | OCCUPIED AREA IS 413. THE FUTURE PHASE 2 & 3 SPACES ARE | | | UNOCCUPIED PENDING FUTURE CONSTRUCTION. | | | | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2016-07-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-07-26 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-07-26 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2016-07-26 13:51:22 | PENDING EMAIL FROM ARCHITECT | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2016-08-08 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2016-08-08 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2016-08-08 |
Time |
16:25 |
Sent To |
B |
|
| Notes |
| 2016-08-08 16:38:16 | PROVISO | | | | | | A SEPARATE LANDSCAPE PERMIT SHALL BE ISSUED. ALL | | | LANDSCAPING SHALL BE INSTALLED AND PASS INSPECTION | | | PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY / | | | COMPLETION. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, PRINCIPAL | | | PLANNER, AT [email protected] OR (561) 822-1448. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2016-07-07 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2016-07-07 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2016-07-06 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2016-07-07 13:48:00 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 07.07.2016 | | | PERMIT NO.: 16040999 | | | ADDRESS: 2823 AUSTRALIAN AVENUE | | | CONTRACTOR/CONTACT: MATT BLACKMAN | | | TELEPHONE NO.: 561.762.7848 | | | SCOPE OF REVIEW: NEW ADDITION. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. A DATA TABLE SHALL BE PROVIDED INDICATING THE | | | FOLLOWING: | | | | | | A. TOTAL GROSS BUILDING SQUARE FOOTAGE (EXISTING AND | | | PROPOSED). | | | | | | D. PERCENT OF OPEN SPACE, LANDSCAPING, BUILDING | | | COVERAGE & IMPERMEABLE SURFACE (EXISTING AND PROPOSED). | | | | | | E. PARKING COMPUTATIONS (PARKING REQUIRED, PROVIDED, | | | ETC. FOR EXISTING AND PROPOSED) | | | | | | F. FLOOR AREA RATIO (FAR) (EXISTING AND PROPOSED). | | | | | | 2. SITE PLAN SHALL INDICATE THE FLOOR AREA FOR THE | | | PROPOSED ADDITION. | | | | | | 3. LANDSCAPE ISLANDS AT THE ENDS OF PARKING ROWS SHALL | | | BE A MINIMUM OF FIVE (5) FEET IN WIDTH, AS MEASURED | | | FROM THE INSIDE OF THE CURB. BASED UPON CONVERSATION | | | WITH JON SCHMIDT, THE FOLLOWING MODIFICATIONS ARE GOING | | | TO BE MADE: | | | | | | A. IMMEDIATELY NORTH OF BUILDING A, THE EASTERN-MOST | | | LANDSCAPE ISLAND WILL BE EXPANDED TO AT LEAST FIVE (5) | | | FEET IN WIDTH BY CONVERTING ONE (1) PARKING SPACE INTO | | | A COMPACT SPACE (8 FEET WIDE). | | | | | | B. IMMEDIATELY SOUTH OF THE DUMPSTER ENCLOSURE, THE | | | ROW OF FOUR (4) PARKING SPACES WILL BE SHIFTED IN A | | | WESTERLY DIRECTION TO PROVIDE A LANDSCAPE ISLAND OF AT | | | LEAST FIVE (5) FEET IN WIDTH ADJACENT TO AUSTRALIAN | | | AVENUE. | | | | | | C. THE ROW OF PARKING ADJACENT TO THE SOUTHEAST CORNER | | | OF BUILDING "C" WILL BE SHIFTED IN AN EASTERLY | | | DIRECTION TO CREATE A LANDSCAPE AREA ALONG THE | | | FOUNDATION OF THE FORMER GARAGE. | | | | | | 4. PLEASE EVALUATE THE CURRENT CONDITION OF THE DOOR | | | EXISTING THE NORTH SIDE OF BUILDING "A" INTO THE | | | PARKING SPACE. A CAR PARKED IN THE SPACE MAY PREVENT | | | THIS DOOR FROM BEING UTILIZED AND COULD BE A POTENTIAL | | | SAFETY HAZARD. IF SO, ADJUSTMENTS WILL NEED TO BE MADE | | | ACCORDINGLY. | | | | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2016-05-06 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2016-05-06 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2016-05-06 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2016-05-06 16:51:39 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 05.06.2016 | | | PERMIT NO.: 16040999 | | | ADDRESS: 2823 AUSTRALIAN AVENUE | | | CONTRACTOR/CONTACT: MATT BLACKMAN | | | TELEPHONE NO.: 561.762.7848 | | | SCOPE OF REVIEW: NEW ADDITION. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. A DATA TABLE SHALL BE PROVIDED INDICATING THE | | | FOLLOWING: | | | | | | A. EXISTING/PROPOSED LAND USE AND ZONING. | | | | | | B. TOTAL ACRES OF THE PROJECT. | | | | | | C. TOTAL GROSS BUILDING SQUARE FOOTAGE (EXISTING AND | | | PROPOSED). | | | | | | D. PERCENT OF OPEN SPACE, LANDSCAPING, BUILDING | | | COVERAGE & IMPERMEABLE SURFACE (EXISTING AND PROPOSED). | | | | | | E. PARKING COMPUTATIONS (PARKING REQUIRED, PROVIDED, | | | ETC. FOR EXISTING AND PROPOSED) | | | | | | F. FLOOR AREA RATIO (FAR) (EXISTING AND PROPOSED). | | | | | | 2. TWO (2) COPIES OF A CURRENT AND ACCURATE SURVEY | | | SHALL BE PROVIDED. | | | | | | 3. SITE PLAN SHALL INDICATE THE SETBACKS, DIMENSIONS, | | | FLOOR AREA, ETC. FOR THE PROPOSED ADDITION. | | | | | | 4. THE GATE UTILIZED FOR THE DUMPSTER SCREENING SHALL | | | CONSIST OF A PERMANENT OPAQUE MATERIAL?CHAINLINK WITH | | | SLATS SHALL NOT BE PERMITTED. | | | | | | 5. A PARKING DETAIL IN CONFORMANCE WITH THE CITY?S | | | ZLDRS SHALL BE PROVIDED. | | | | | | 6. LANDSCAPE ISLANDS AT THE ENDS OF PARKING ROWS SHALL | | | BE A MINIMUM OF FIVE (5) FEET IN WIDTH, AS MEASURED | | | FROM THE INSIDE OF THE CURB (ISLANDS/BUFFER ALONG | | | AUSTRALIAN AVENUE DOES NOT APPEAR TO MEET THIS | | | REQUIREMENT). | | | | | | 7. IT APPEARS THAT THERE IS A LOSS OF PARKING FROM WHAT | | | CURRENTLY EXISTS ON THE PROPERTY; PARKING DATA SHALL BE | | | PROVIDED INDICATING THAT THE SITE CONFORMS TO THE | | | MINIMUM REQUIREMENTS OF THE CITY?S ZLDRS. IF THE SITE | | | IS CURRENTLY NONCONFORMING, THAT IS FINE AND MAY | | | CONTINUE, BUT PARKING WOULD HAVE TO BE PROVIDED FOR THE | | | ADDITIONAL SQUARE FOOTAGE (NO PARKING COULD BE | | | REMOVED). | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|