Plan Review Details - Permit 16040984
Plan Review Stops For Permit 16040984
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-06-10 Cont ID  
Sent By cthroop Date 2016-06-10 Time 15:31 Rev Time 0.00
Received By cthroop Date 2016-06-09 Time 09:24 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-05-16 Cont ID  
Sent By cthroop Date 2016-05-16 Time 15:48 Rev Time 0.00
Received By cthroop Date 2016-05-16 Time 15:25 Sent To  
Notes
2016-05-16 15:53:201ST REVIEW: FBC 2014 5TH ED
 CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-7918
 [email protected]
  
 1. PROVIDE PRODUCT APPROVALS PER FAC RULE 9N-3.
 2. PROVIDE WIND LOAD ENGINEERING FOR PERIMETER AND
 CORNERS OF ROOFING SYSTEM PER NOTE 7 &/OR 9, GENERAL
 LIMITATIONS, NOA NO. 14-0529.02.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY
 FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. SPECIFICALLY, PROVIDE ROOFING,
 WINDOW, AND DOOR SUBMITTALS.
  
 FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-06-09 Cont ID  
Sent By mvaldes Date 2016-06-09 Time 16:32 Rev Time 0.00
Received By mvaldes Date 2016-06-09 Time 16:20 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-04-28 Cont ID  
Sent By mvaldes Date 2016-04-28 Time 12:16 Rev Time 0.00
Received By mvaldes Date 2016-04-28 Time 11:17 Sent To  
Notes
2016-04-28 12:19:24JOB PERMIT NUMBER: 16040984
 JOB ADDRESS: 313 ARLINGTON RD
 WEST PALM BEACH FLORIDA
 DATE: APRIL 28 2016
  ELECTRICAL PLAN REVIEW COMMENTS
  
 THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION
 HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF
 THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC,
 (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST
 PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF
 SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED.
  
 - RISER DIAGRAM MISSING THE INTER-SYSTEM BONDING
 TERMINAL. FBC-R E3609.2
 - FBC-R E3902.12.13 - OUTLETS TO BE AFCI PROTECTED. (
 IF ANY MODIFICATIONS TO AREAS SUCH AS FAMILY ROOMS,
 DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS,
 BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS,
 HALLWAYS, OR SIMILAR ROOMS )
 - FBC-R E4002.14 TAMPER-RESISTANT RECEPTACLES IN
 DWELLING UNITS. IN ALL AREAS SPECIFIED IN 210.52, ALL
 125-VOLT, 15 AND 20 AMPERE RECEPTACLES SHALL BE LISTED
 TAMPER RESISTANT RECEPTACLES.
 - REFERENCE UNDERGROUND CLEARANCE REQUIRED PER FBC-R
 E3803.1.2 AND RED WARNING RIBBON FOR SERVICE CONDUCTORS
 AT LEAST 12 ? ABOVE LATERAL RACEWAY.
 - PANEL SCHEDULES REFLECT INCORRECT WATTAGE FOR RANGE
 4000 VA ? DRYER 2250 VA ? , A/C 5000 VA HOWEVER LOAD
 CALCS SHOWS 10000 VA FOR HEAT ? CLARIFY AND CORRECT
 ACCORDINGLY. FBC-R E3704.2.2
 - BATHROOMS REQUIRE A 20 AMP CIRCUIT OUTLET THAT SERVES
 NO OTHER LOAD UNLESS LIGHTING WITHIN THE SAME BATH IS
 ATTACHED TO GFCI RECEPTACLE. FBC-R E3703.4
 - NEW RECESSED LIGHTING SHALL BE 75 % HIGH EFFICIENCY ,
 IC RATED AND SEALED TO NOT COMPROMISE BUILDING THERMAL
 ENVELOPE. ( 2CFM ) FBC- E R 402.4.4 / 404.1.1
  
 PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE
 MENTIONED DEFICIENCIES.
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE
 LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE
 STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD
 INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE
 OR ACTION TO SAME. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE
 PREVIOUSLY REVIEWED SHEETS FOR COMPARISON.
 CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 FBC 2014 5TH ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 516-805-6713
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-06-13 Cont ID  
Sent By jroach Date 2016-06-13 Time 15:23 Rev Time 0.00
Received By jroach Date 2016-06-03 Time 11:33 Sent To  
Notes
2016-06-03 11:33:28R11

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-05-16 Cont ID  
Sent By cthroop Date 2016-05-16 Time 15:48 Rev Time 0.00
Received By cthroop Date 2016-04-21 Time 09:02 Sent To  
Notes
2016-04-22 09:02:51R33

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-06-10 Cont ID  
Sent By skennedy Date 2016-06-10 Time 15:24 Rev Time 0.00
Received By skennedy Date 2016-06-10 Time 15:24 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2016-05-02 Cont ID  
Sent By jvalido Date 2016-05-02 Time 16:34 Rev Time 0.00
Received By jvalido Date 2016-05-02 Time 16:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-06-09 Cont ID  
Sent By gjohnson Date 2016-06-09 Time 06:22 Rev Time 0.00
Received By gjohnson Date 2016-06-09 Time 06:22 Sent To  
Notes
2016-06-09 06:22:18REVIEWED AND APPROVED BY GEORGE EARL

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-05-02 Cont ID  
Sent By gearl Date 2016-05-02 Time 09:26 Rev Time 0.00
Received By gearl Date 2016-05-02 Time 09:26 Sent To  
Notes
2016-05-02 09:29:16 
  
  
 1. NEED WATER HEATER MANUFACTOR SPEC'S SHEET ON SITE AT
 FINAL INSPECTION
  
  
 GEORGE EARL - PLUMBING PLANS REVIEWER

Review Stop Z ZONING
Rev No 2 Status P Date 2016-06-13 Cont ID  
Sent By jroach Date 2016-06-13 Time 15:23 Rev Time 0.00
Received By jroach Date 2016-06-13 Time 15:17 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2016-05-06 Cont ID  
Sent By jroach Date 2016-05-06 Time 14:51 Rev Time 0.00
Received By jroach Date 2016-05-06 Time 14:46 Sent To  
Notes
2016-05-06 14:51:09ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 05.06.2016
 PERMIT NO.: 16040984
 ADDRESS: 313 ARLINGTON ROAD
 CONTRACTOR/CONTACT: WILL MURILLO
 TELEPHONE NO.: 561.827.6645
 SCOPE OF REVIEW: NEW PORCH, INTERIOR RENOVATION, ETC.
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. PURSUANT TO SECTION 94-441 OF THE CITY'S ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDRS), BECAUSE THE
 PROPOSED SCOPE OF WORK EXCEEDS 50 PERCENT OF THE VALUE
 OF THE EXISTING STRUCTURE, THE SITE SHALL BE BROUGHT
 INTO COMPLIANCE WITH ARTICLE XIV (LANDSCAPING) OF THE
 ZLDRS. PLANS SHALL BE SUBMITTED INDICATING SUCH. IF
 EXISTING MATERIAL IS SHOWN ON THE PLANS AND ALL
 PROVISIONS OF ARTICLE XIV HAVE BEEN MET, THEN NO
 ADDITIONAL PERMIT/INSTALLATION IS REQUIRED. IF THE
 EXISTING MATERIAL ON SITE DOES NOT CONFORM TO ALL OF
 THE REQUIREMENTS OF ARTICLE XIV, THEN ADDITIONAL
 MATERIAL WILL NEED TO BE SHOWN ON THE PLANS AND
 PERMITTED UNDER A LANDSCAPE PERMIT. PLEASE NOTE THAT
 PLANS SHOULD INCLUDE, BUT NOT BE LIMITED TO, THE
 FOLLOWING:
  
 A. THE LOCATION OF ALL EXISTING AND PROPOSED
 STRUCTURES, IMPROVEMENTS, ETC.
  
 B. THE LOCATION OF ALL EXISTING AND PROPOSED TREES,
 SHRUBS, GROUND COVERS, ETC.
  
 C. THE LOCATION OF UTILITY AND DRAINAGE EASEMENTS,
 OVERHEAD LINES, WATER METERS, TRANSFORMERS, CHECK
 VALVES, CLEAN OUTS, FIRE HYDRANTS, LIGHT POLES, ETC.
 THAT MAY IMPACT LANDSCAPING.
  
 D. TABULATION TABLE INDICATING HOW THE EXISTING AND
 PROPOSED PLANT MATERIAL COMPLIES WITH ARTICLE XIV.
  
 E. SPECIES, QUANTITY, HEIGHT, SPREAD, SPACING, AND
 LOCATION OF THE EXISTING AND PROPOSED PLANT MATERIAL.
  
 F. STATEMENT THAT ALL LANDSCAPE AREAS WILL BE PROVIDED
 WITH A PERMANENT AUTOMATIC IRRIGATION SYSTEM, INCLUDING
 THE ADJACENT RIGHT-OF-WAY (PLEASE NOTE THAT ANY NEW
 IRRIGATION SHALL BE DONE UNDER A SEPARATE PERMIT).
  
 2. LANDSCAPE SCREENING WILL NEED TO BE PROVIDED AROUND
 THE NEW A/C COMPRESSOR BLOCKING IT FROM VIEW FROM THE
 PUBLIC RIGHT-OF-WAY.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 F: 561.822.1460
  
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved