Plan Review Details - Permit 16040967
Plan Review Stops For Permit 16040967
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-07-26 Cont ID  
Sent By rmcdouga Date 2016-07-26 Time 15:29 Rev Time 0.00
Received By rmcdouga Date 2016-07-26 Time 15:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-07-01 Cont ID  
Sent By rmcdouga Date 2016-07-01 Time 18:44 Rev Time 0.00
Received By rmcdouga Date 2016-07-01 Time 16:57 Sent To  
Notes
2016-07-01 18:46:54COORDINATE THE SITE PLAN WITH THE SURVEY/DRAINAGE PLAN
 PER ZONING COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-05-24 Cont ID  
Sent By rmcdouga Date 2016-05-24 Time 17:54 Rev Time 0.00
Received By rmcdouga Date 2016-05-23 Time 14:10 Sent To  
Notes
2016-05-24 16:16:29REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT A SURFACE WATER DRAINAGE PLAN THAT SHOWS
 COMPLIANCE WITH FBC-R401.3.
  
 2) A CORPORATION CAN NOT SIGN THE ENERGY FORM FOR THE
 OWNER/AGENT. THE OWNER/AGENT LINE ON THE ENERGY FORM
 NEEDS TO BE SIGNED BY A PERSON, SUCH AS A PRINCIPLE IN
 THE CORPORATION.
  
 3) THE CLIMATE ZONE FOR PALM BEACH IS 1A NOT 2. SEE FBC
 ENERGY CONSERVATION TABLE R301.1.
  
 4) THE ENERGY FORM INDICATES THAT THE CROSS VENTILATION
 OPTION IS BEING USED. SHOW ON THE PLANS THE
 INSTALLATION CRITERIA IN FBC ENERGY CONSERVATION
 SECTION R405.7.4 THAT IS REQUIRED. PROVIDE CALCULATIONS
 THAT SHOW THE OPERABLE APERTURE AREAS TOTAL A MINIMUM
 OF 12 PERCENT OF THE FLOOR AREA FOR ALL PRIMARY LIVING
 AREAS AND BEDROOMS. SPECIFY THAT INSECT SCREENS ARE
 REQUIRED FOR ALL WINDOWS AND DOORS THAT ARE TO BE
 CONSIDERED OPERABLE AREA. ALL SCREENED ENTRY DOORS AND
 INTERIOR DOORS IN THE VENTILATED AREAS SHALL BE
 PROVIDED WITH DEVICES TO HOLD THE DOOR IN AN OPEN
 POSITION OR OPERABLE LOUVERS.
  
 5) THE DETAILS ON SHEET S.2 SPECIFY A STANDING SEAM
 METAL ROOF AND SHEET S.1 SPECIFIES ASPHALT SHINGLES.
 PLEASE CLARIFY.
  
 6) SUBMIT TWO SETS OF THE INSTALLATION INSTRUCTIONS FOR
 THE MASONITE INTERNATIONAL EXTERIOR DOORS (FL 4904-R7).
 DCA RULE 9N-3
  
 7) ON SHEET S.2 THE WRONG PRODUCT APPROVAL IS LISTED IN
 THE SCHEDULE FOR DOOR #3, THE 100 SERIES OUTSWING
 FRENCH DOORS. IT SHOULD BE NOA NO. 15-0706.03.
  
 8) THE VALUE HAS BEEN INCREASED TO $249,257.00 BASED ON
 ICC VALUATION DATA. FBC 109.3
  
 9) A SEPARATE PERMIT, APPLICATION AND REVIEW IS
 REQUIRED FOR THE DRIVEWAY AND APRON.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-05-02 Cont ID  
Sent By mvaldes Date 2016-05-02 Time 13:10 Rev Time 0.00
Received By mvaldes Date 2016-05-02 Time 11:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-07-26 Cont ID  
Sent By rmcdouga Date 2016-07-26 Time 15:59 Rev Time 0.00
Received By rmcdouga Date 2016-07-06 Time 14:06 Sent To  
Notes
2016-07-06 14:06:41RESUB ROUTED TO ESCHNEID VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-07-01 Cont ID  
Sent By rmcdouga Date 2016-07-01 Time 18:44 Rev Time 0.00
Received By rmcdouga Date 2016-06-13 Time 10:39 Sent To  
Notes
2016-06-13 10:40:10RESUB ROUTED TO ESCHNEIDER VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-05-24 Cont ID  
Sent By rmcdouga Date 2016-05-24 Time 17:55 Rev Time 0.00
Received By rmcdouga Date 2016-04-21 Time 15:47 Sent To  
Notes
2016-04-21 15:47:09R01

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2016-07-26 Cont ID  
Sent By rmcdouga Date 2016-07-26 Time 15:48 Rev Time 0.00
Received By rmcdouga Date 2016-07-26 Time 15:48 Sent To  
Notes
2016-07-26 15:51:24MU 2016-16866, NO FEES WERE DUE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2016-07-01 Cont ID  
Sent By rmcdouga Date 2016-07-01 Time 16:57 Rev Time 0.00
Received By rmcdouga Date 2016-07-01 Time 16:57 Sent To  
Notes
2016-07-01 16:58:18BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-05-23 Cont ID  
Sent By rmcdouga Date 2016-05-23 Time 14:08 Rev Time 0.00
Received By rmcdouga Date 2016-05-23 Time 14:08 Sent To  
Notes
2016-05-23 14:10:32BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2016-05-23 Cont ID  
Sent By rmcdouga Date 2016-05-23 Time 15:02 Rev Time 0.00
Received By rmcdouga Date 2016-05-23 Time 15:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-05-02 Cont ID  
Sent By gjohnson Date 2016-05-02 Time 14:47 Rev Time 0.00
Received By gjohnson Date 2016-05-02 Time 14:47 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2016-07-26 Cont ID  
Sent By rmcdouga Date 2016-07-26 Time 15:45 Rev Time 0.00
Received By rmcdouga Date 2016-07-26 Time 15:45 Sent To  
Notes
2016-07-26 15:45:09ROOFING MATERIALS
 -GAF ASPHALT SHINGLES FL#10124.1

Review Stop Z ZONING
Rev No 3 Status P Date 2016-07-26 Cont ID  
Sent By eschneid Date 2016-07-26 Time 10:22 Rev Time 0.25
Received By eschneid Date 2016-07-26 Time 10:22 Sent To B
Notes
2016-07-26 10:57:01THIS PLANS WITH THIS PERMIT ARE FOR THE FENCE AND
 DRIVEWAY PERMITS AS WELL. ZONING DID NOT PASS FENCE
 PERMIT, SO PLANS MAY NOT BE ISSUED.

Review Stop Z ZONING
Rev No 2 Status F Date 2016-06-17 Cont ID  
Sent By eschneid Date 2016-06-17 Time 17:39 Rev Time 0.50
Received By eschneid Date 2016-06-17 Time 17:28 Sent To  
Notes
2016-06-17 17:39:06FAILED
  
 1) THE PROPOSED SITE PLAN ON SHEET S.1 SHOWS THE HOUSE
 HAVING SETBACKS OF 9 FEET 2 INCHES AND 7 FEET 6 INCHES.
 THE SURVEY SITE PLAN SHOWS THE HOUSE HAVING 8 FEET 3
 INCHES ON BOTH SIDES OF THE HOUSE. ALL PLANS SHALL SHOW
 THE SAME CONDITIONS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.

Review Stop Z ZONING
Rev No 1 Status F Date 2016-05-13 Cont ID  
Sent By eschneid Date 2016-05-13 Time 08:47 Rev Time 1.00
Received By eschneid Date 2016-05-12 Time 15:39 Sent To  
Notes
2016-05-13 08:54:42FAILED
  
 1) THE PROPOSED PLAN VIEW ON SHEET S.2 SHALL SHOW THE
 DIMENSIONS OF THE A/C PAD AND THE A/C.
  
 2) THE PROPOSED SITE PLAN ON SHEET S.1 SHALL SHOW THE
 SETBACK DIMENSION FROM THE PROPERTY LINE TO THE A/C
 PAD. THE A/C PAD SHALL BE NO CLOSER THAN 4 FEET 4
 INCHES FROM THE PROPERTY LINE.
  
 3) ZONING WILL NOT APPROVE THIS PERMIT UNTIL A
 LANDSCAPE PERMIT HAS BEEN SUBMITTED.
  
 4) THE LANDSCAPE, IRRIGATION, FENCE AND DRIVEWAY
 REQUIRE SEPARATE PERMITS, WITH PLANS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.