Plan Review Details - Permit 16040931
| Plan Review Stops For Permit 16040931 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-06-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-06-23 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-06-23 |
Time |
12:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-05-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-05-18 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-05-18 |
Time |
17:15 |
Sent To |
E |
|
| Notes |
| 2016-05-18 17:16:46 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. PROVIDE A FLOOR PLAN SHOWING ROOMS WHICH OPEN INTO | | | THE PROPOSED SUNROOM. IF ANY BEDROOMS ARE AFFECTED, | | | SHOW ALTERNATE EMERGENCY ESCAPE AND RESCUE OPENING, FBC | | | RESIDENTIAL 310. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-06-06 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-06-06 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-06-06 |
Time |
09:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-05-18 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-05-18 |
Time |
18:39 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-05-18 |
Time |
18:29 |
Sent To |
|
|
| Notes |
| 2016-05-18 18:44:14 | REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | | | | NEC 210.52 (A) RECEPTACLES SHALL BE INSTALLED IN THE | | | SUNROOM PROVIDE FLOOR PLAN SHOWING THE OUTLETS. | | | NEC 210.52 (A)(1) SPACING. RECEPTACLES SHALL BE | | | INSTALLED SUCH THAT NO POINT MEASURED HORIZONTALLY | | | ALONG THE FLOOR LINE IN ANY WALL SPACE IS MORE THAN 6 | | | FT. FROM A RECEPTACLE OUTLET. THIS INCLUDES THE | | | DISTANCE FROM THE EDGE OF THE WALL. | | | NEC 210.52 (A)(2) WALL SPACE. ANY WALL SPACE 2 FT. OR | | | MORE IN WIDTH SHALL REQUIRE A RECEPTACLE. | | | NEC 210.12B - OUTLETS TO BE AFCI PROTECTED. | | | SMOKE ALARMS REQUIRED PER RESIDENTIAL CODE SECTIONS 314 | | | & 315. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-06-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-06-23 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-06-03 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2016-06-03 14:24:56 | RESUB ROUTED TO MVALDES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-05-18 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-05-18 |
Time |
18:44 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-04-20 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2016-05-18 17:17:13 | 5/18 TO ELEC BOX | | | | | | | | 2016-04-21 10:04:44 | ROUTED TO ZONING |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2016-06-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-06-23 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-06-23 |
Time |
12:43 |
Sent To |
|
|
| Notes |
| 2016-06-23 12:44:51 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. IMPACT FEE ASSESSMENT REQUIRED BY PALM BEACH COUNTY. | | | THE PLANS ARE TO BE STAMPED AND THE RECEIPT SHOWING | | | FEES WERE PAID (IF APPLICABLE) PROVIDED. | | | | | | PLEASE CONTACT 561-233-5025 FOR MORE INFORMATION. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-04-26 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2016-04-26 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2016-04-26 |
Time |
17:24 |
Sent To |
B |
|
| Notes |
|
|
|