Plan Review Details - Permit 16040572
Plan Review Stops For Permit 16040572
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-05-14 Cont ID  
Sent By jwitmer Date 2016-05-14 Time 07:59 Rev Time 0.00
Received By jwitmer Date 2016-05-14 Time 07:30 Sent To  
Notes
2016-05-14 07:47:06BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16040572
 ADD: 641 34TH ST
 CONT: HALL ROOFING CONSTRUCTION
 TEL: 561-557-5136
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: SAT. MAY 14/2016
 ACTION: BUILDING PROVISO
  
 1) ROOFING ASPHALT SHINGLES 2014 < 4/12 PITCH FBC-R
 R905.2.7 UNDERLAYMENT APPLICATION. UNDERLAYMENT SHALL
 BE INSTALLED USING ONE OF THE FOLLOWING METHODS:
 1. FOR ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS
 HORIZONTAL (17-PERCENT SLOPE), AND LESS THAN FOUR UNITS
 VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE).
 UNDERLAYMENT SHALL COMPLY WITH ASTM D 226, TYPE I OR
 TYPE II OR ASTM D 4869, TYPE II OR TYPE IV OR ASTM D
 6757 AND SHALL BE TWO LAYERS APPLIED IN THE FOLLOWING
 MANNER. APPLY A 19-INCH (483 MM) STRIP OF UNDERLAYMENT
 FELT PARALLEL TO AND STARTING AT THE EAVES, FASTENED
 SUFFICIENTLY TO HOLD IN PLACE. STARTING AT THE EAVE,
 APPLY 36-INCH-WIDE SHEETS OF UNDERLAYMENT, OVERLAPPING
 SUCCESSIVE SHEETS 19 INCHES (483 MM), AND FASTENED WITH
 A 1-INCH (25 MM) ROUND PLASTIC CAP, METAL CAP NAILS OR
 NAILS AND TIN-TABS ATTACHED TO A NAILABLE DECK WITH ONE
 ROW IN THE FIELD OF THE SHEET WITH A MAXIMUM FASTENER
 SPACING OF 12 INCHES (305 MM) O.C., AND ONE ROW AT THE
 OVERLAPS FASTENED 6 INCHES O.C.
  
 2.AS AN ALTERNATIVE, THE ENTIRE ROOF DECK SHALL BE
 COVERED WITH AN APPROVED SELF-ADHERING POLYMER MODIFIED
 BITUMEN SHEET MEETING ASTM D 1970 OR AN APPROVED
 SELF-ADHERING SYNTHETIC UNDERLAYMENT INSTALLED IN
 ACCORDANCE WITH THE MANUFACTURER?S INSTALLATION
 INSTRUCTIONS.
  
 2) PROVISO: NOTICE: EFFECTIVE APRIL 1/2016 THE
 REFERENCED MIAMI-DADE COUNTY ELECTROGALVANIZED
 FASTENERS LISTINGS ARE SUSPENDED:
 11--1019.02 & 11-1019.03 BLUELINX CORP.
 12-0423.06 CONTINENAL MATERIALS, INC.
 15-1123.04 PRIME SOURCE BUILDING PRODUCTS, INC.
 13-0530.01 SPECIALTY FASTENING SYSTEM
 12-0423.03 & 12-0423.04 SUMMIT CONGLOMERATE, LLC
 12-1205.11, 12-1205.13 & 13-05 & 13-0514.05 WEATHERPRO,
 LLC
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-04-12 Cont ID  
Sent By jwitmer Date 2016-04-12 Time 10:25 Rev Time 0.00
Received By jwitmer Date 2016-04-12 Time 10:03 Sent To  
Notes
2016-04-12 10:25:24BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16040572
 ADD: 641 34TH ST
 CONT: HALL ROOFING CONSTRUCTION
 TEL: 561-557-5136
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. APRIL 12/2016
 ACTION: DENIED
  
 1) ROOFING PERMIT FOR THE FLAT PORTION OF THE ROOF THE
 NOA 13-0514.12 MULE-HIDESELF ADHERRING ROOF SYSTEMS
 OVER WOOD DECKS WAS SUBMITTED. PLEASE NOTE NON OF THE
 SUB-SYSTEMS WERE IDENTIFIED AS TO WHICH WERE TO BE
 INSTALLED. PLEASE IDENTIFY
 AND NOTE THE ASSOCIATED PRESSURES, ALL WILL REQUIRE
 ENHANCED FASTENING BY A DESIGN PROFESSIONAL, USING RAS
 117 CALCULATIONS FOR ROOF ZONES 2 & 3.
 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED TO
 DETERMINE CODE COMPLIANCE.
 2014 FBC-B 1603.1.4 WIND DESIGN DATA.
  
 2) PROVISO: NOTICE: EFFECTIVE APRIL 1/2016 THE
 REFERENCED MIAMI-DADE COUNTY ELECTROGALVANIZED
 FASTENERS LISTINGS ARE SUSPENDED:
 11--1019.02 & 11-1019.03 BLUELINX CORP.
 12-0423.06 CONTINENAL MATERIALS, INC.
 15-1123.04 PRIME SOURCE BUILDING PRODUCTS, INC.
 13-0530.01 SPECIALTY FASTENING SYSTEM
 12-0423.03 & 12-0423.04 SUMMIT CONGLOMERATE, LLC
 12-1205.11, 12-1205.13 & 13-05 & 13-0514.05 WEATHERPRO,
 LLC
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-05-14 Cont ID  
Sent By   Date 2016-05-14 Time   Rev Time 0.00
Received By lmarchan Date 2016-05-12 Time 09:50 Sent To  
Notes
2016-05-13 09:50:26RESUB ROUTED TO JWITMER

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-04-12 Cont ID  
Sent By jwitmer Date 2016-04-12 Time 10:25 Rev Time 0.00
Received By jwitmer Date 2016-04-11 Time 09:29 Sent To  
Notes
2016-04-12 09:29:59JWITMER