Plan Review Details - Permit 16040401
| Plan Review Stops For Permit 16040401 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-06-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-06-07 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-06-07 |
Time |
12:32 |
Sent To |
E |
|
| Notes |
| 2016-06-07 13:08:45 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: | | | A) EXTERIOR DOOR #5 BY THE DINING AREA. NOTE: SEE SIZE | | | (HEIGHT) SPECIFIED ON THE DOOR SCHEDULE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-05-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-05-03 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-05-03 |
Time |
07:39 |
Sent To |
|
|
| Notes |
| 2016-05-03 09:15:20 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- EXISTING FLOOR PLAN SHOWS SINGLE ENTRY DOOR WITH 2 | | | SIDELITES. THE WIDOW AND DOOR SCHEDULE SHOWS A 5'0" X | | | 6'8" DOUBLE DOOR. THIS WILL REDUCE THE SIZE OF THE | | | EGRESS DOOR. NEED TO HAVE AT LEST 32" CLEAR OPENING ON | | | ONE DOOR LEAF. THEREFORE, THE PROPOSED DOUBLE DOOR | | | DOESN'T COMPLY. REVISE AS REQUIRED. SEC. 704 | | | FBC-EXISTING BUILDING, 5TH EDITION (2014). | | | | | | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: | | | A) EXTERIOR DOOR #5 BY THE DINING AREA. NOTE: SEE SIZE | | | SPECIFIED ON THE DOOR SCHEDULE. | | | | | | B) ENTRY DOOR WITH TRANSOM ASSEMBLY AS SPECIFIED ON | | | PLANS. NOTE: COORDINATE WITH ITEM #1 ABOVE. | | | | | | 3- ENGINEER TO REVIEW AND APPROVE ABOVE PRODUCT | | | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY | | | AMENDMENTS. | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-06-08 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-06-08 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-06-08 |
Time |
11:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-04-13 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-04-13 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-04-13 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2016-04-13 09:16:43 | REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6713 | | | [email protected] | | | | | | | | | - ADD THE FOLLOWING ELECTRICAL NOTES | | | | | | 1 NEC 210.12 B AFCI PROTECTION | | | 2 NEC 406.11 TAMPER RESISTANT RECEPTACLES | | | 3 NEC 314.27 PADDLE FANS ( 70 POUND RATED BOX. ) | | | | | | - SMOKE ALARMS REQUIRED PER RESIDENTIAL CODE SECTIONS | | | 314 & 315 | | | - RECESSED LIGHTS SHALL BE 75 % HIGH EFFICIENT AS WELL | | | AS IC RATED AND SEALED TO NOT COMPROMISE THE BUILDING | | | THERMAL ENVELOPE. ( 2 CFM ) | | | - PROVIDE EXISTING RISER DIAGRAM WITH CONDUIT AND WIRE | | | SIZES, GROUNDING DETAIL , A PANEL SCHEDULE SHOWING | | | OVERCURRENT PROTECTION INFORMATION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-06-08 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-06-08 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-05-24 |
Time |
12:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-05-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-05-03 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-04-07 |
Time |
14:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-06-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-06-02 |
Time |
06:28 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-06-02 |
Time |
06:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-04-25 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-04-25 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-04-25 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2016-04-25 14:57:43 | PER GEORGE EARL 0013-B |
|
|
|